cs.CVApr 13, 2026

Seeing Through the Tool: A Controlled Benchmark for Occlusion Robustness in Foundation Segmentation Models

Authors: Nhan Ho, Luu Le, Thanh-Huy Nguyen, Thien Nguyen, Xiaofeng Liu, Ulas Bagci

Organizations: Stony Brook University, USA · AIMA Research Lab · Carnegie Mellon University, USA · Yale University, USA · 

Abstract

Occlusion, where target structures are partially hidden by surgical instruments or overlapping tissues, remains a critical yet underexplored challenge for foundation segmentation models in clinical endoscopy. We introduce OccSAM-Bench, a benchmark designed to systematically evaluate SAM-family models under controlled, synthesized surgical occlusion. Our framework simulates two occlusion types (i.e., surgical tool overlay and cutout) across three calibrated severity levels on three public polyp datasets. We propose a novel three-region evaluation protocol that decomposes segmentation performance into full, visible-only, and invisible targets. This metric exposes behaviors that standard amodal evaluation obscures, revealing two distinct model archetypes: Occluder-Aware models (SAM, SAM 2, SAM 3, MedSAM3), which prioritize visible tissue delineation and reject instruments, and Occluder-Agnostic models (MedSAM, MedSAM2), which confidently predict into occluded regions. SAM-Med2D aligns with neither and underperforms across all conditions. Ultimately, our results demonstrate that occlusion robustness is not uniform across architectures, and model selection must be driven by specific clinical intent-whether prioritizing conservative visible-tissue segmentation or the amodal inference of hidden anatomy.

Figures & tables

Appendix figures & tables12 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 28, 2026

Robustness Evaluation of a Foundation Segmentation Model Under Simulated Domain Shifts in Abdominal CT: Implications for Health Digital Twin Deployment

Foundation segmentation models such as the Segment Anything Model (SAM) have demonstrated strong generalization across natural images; however, their robustness under clinically realistic medical imaging domain shifts remains insufficiently quantified. We present a systematic slice-level robustness audit of SAM (ViT-B) for spleen segmentation in abdominal CT using 1,051 nonempty slices from 41 volumes in the Medical Segmentation Decathlon. A standardized ground-truth-derived bounding-box protocol was used to isolate encoder robustness from prompt uncertainty. Controlled perturbations simulating inter-scanner variability, including Gaussian noise, blur, contrast scaling, gamma correction, and resolution mismatch, were applied across ten conditions. The clean baseline achieved a mean Dice score of 0.9145 (95% CI: [0.909, 0.919]) with a failure rate of 0.67%. Across all perturbations, the absolute mean ΔDice remained below 0.01. Paired Wilcoxon signed-rank tests with Benjamini-Hochberg false discovery rate correction identified statistically significant but small-magnitude changes under selected conditions, while McNemar analysis showed no significant increase in failure probability. These findings indicate that SAM exhibits stable segmentation behavior under moderate CT domain shifts, supporting its role as a robust foundation baseline for medical image segmentation research. As health digital twins increasingly incorporate foundation segmentation models for anatomical modeling and organ-level monitoring, formal characterization of robustness under real-world imaging variability is a necessary step toward trustworthy deployment.
Aug 9, 2026

Toward Mask Annotation-Free Surgical Instrument Segmentation from Endoscopic Images Using Text-Prompted Segment Anything Model 3 (SAM3)

Surgical instrument segmentation is a fundamental task for computer-assisted interventions, yet most existing methods rely on pixel-level annotations or manual spatial prompts, which limit scalability and automation. The recently introduced Segment Anything Model 3 (SAM3) offers a pathway to annotation-free, automatic segmentation via text-based prompting; however, the instrument name as a text prompt could not be directly used due to a large domain gap. To overcome these limitations, we propose a two-stage framework that achieves instance-level segmentation without requiring ground truth masks or manual interaction. In the first stage, we leverage a natural-language-aligned generic prompt - "tool" - to produce binary masks using SAM3's zero-shot capability. In the second stage, these masks are extended to instance-level by integrating a vision-language model (Qwen) that is fine-tuned on SAM3-generated masked regions for instrument classification. We evaluate our approach on the EndoVis 2017 and 2018 datasets. Results show that, while our two-stage approach does not reach the performance of current fully supervised methods, it significantly outperforms the direct use of SAM3 for instance-level instrument segmentation with text prompts. Overall, our findings highlight both the limitations and potential of SAM3, suggesting a promising direction toward annotation-free surgical instrument segmentation.
Apr 10, 2026

RobustMedSAM: Degradation-Resilient Medical Image Segmentation via Robust Foundation Model Adaptation

Medical image segmentation models built on Segment Anything Model (SAM) achieve strong performance on clean benchmarks, yet their reliability often degrades under realistic image corruptions such as noise, blur, motion artifacts, and modality-specific distortions. Existing approaches address either medical-domain adaptation or corruption robustness, but not both jointly. In SAM, we find that these capabilities are concentrated in complementary modules: the image encoder preserves medical priors, while the mask decoder governs corruption robustness. Motivated by this observation, we propose RobustMedSAM, which adopts module-wise checkpoint fusion by initializing the image encoder from MedSAM and the mask decoder from RobustSAM under a shared ViT-B architecture. We then fine-tune only the mask decoder on 35 medical datasets from MedSegBench, spanning six imaging modalities and 12 corruption types, while freezing the remaining components to preserve pretrained medical representations. We additionally investigate an SVD-based parameter-efficient variant for limited encoder adaptation. Experiments on both in-distribution and out-of-distribution benchmarks show that RobustMedSAM improves degraded-image Dice from 0.613 to 0.719 (+0.106) over SAM, demonstrating that structured fusion of complementary pretrained models is an effective and practical approach for robust medical image segmentation.