Convolutional neural networks (CNNs) have become increasingly difficult to deploy in resource-constrained environments due to their large memory and computational requirements. Although low-rank compression methods can reduce this burden, most existing approaches compress spatial and channel redundancy independently and therefore do not fully exploit the localised structure within convolutional feature maps. This paper proposes a hierarchical spatio-channel low-rank compression framework for CNNs that exploits redundancy across spatial regions and channel activations. Unlike conventional methods, which apply a uniform decomposition across an entire layer, the proposed approach first partitions feature maps into spatial regions, then groups channels according to their co-activation patterns within each region, and finally applies rank-adaptive SVD to each resulting spatio-channel cluster. The method is evaluated on an AlexNet-based brain tumour MRI classification model and compared with Global SVD and Tucker decomposition under 3× and 6× compression budgets. Our method outperforms both baselines, reducing FLOPs from 8.21G to 1.55G (81.1% reduction), achieving a 1.38× inference speed-up, and increasing classification accuracy from 87.76% to 89.80%. The method also improves the macro F1-score and performance on challenging classes such as meningioma. A hyper-parameter trade-off analysis demonstrates that the framework provides Pareto-optimal configurations, enabling control over the balance between compression and predictive performance. Moderate clustering with adaptive rank selection yields strong results. Bootstrap standard errors are reported for all classification metrics.
Medical image segmentation models require both high accuracy and lightweight design to accommodate real-world medical applications. The deployment of these models on resource-limited medical platforms remains a significant challenge due to their high computational and parameter requirements. Existing pruning methods for model compression mostly overlook the intrinsic connections and similarity between the internal structures of complex deep neural networks. As a result, compressed models may not effectively retain the basic features of the pretrained network. To solve this problem, we propose a hierarchical clustering compression method for medical image segmentation models (MIS-HCC). This approach employs hierarchical clustering to partition channels and fuse their parameters efficiently. Specifically, it leverages the Wasserstein distance to represent similarity of channels within layers of pre-trained network, forming a similarity matrix that guides the clustering process. Channels within each cluster are then fused to produce a compressed network. Experimental results on three medical image datasets application demonstrate that MIS-HCC outperforms the state-of-the-art methods in both accuracy and compression efficiency, offering an effective solution for deploying medical image segmentation models on resource-limited medical platforms.
Deep learning models have shown strong performance in medical image analysis, but deploying them in low-resource clinical environments remains difficult due to computational, memory, and power constraints. This paper presents a multi-strategy compression framework for brain tumor classification from MRI, encompassing quantization-aware training, knowledge distillation from a DenseNet-101 teacher to a compact DenseNet-32 student with low-bit post-training quantization, and Float16 post-training quantization on a lightweight MobileNetV2 backbone. Using a multi-class brain tumor MRI dataset containing glioma, meningioma, pituitary tumors, and healthy controls, we provide full experimental validation of the MobileNetV2-based pipeline, training the classifier through a three-stage transfer learning process and applying Float16 quantization via TensorFlow Lite. The DenseNet-based distillation and quantization-aware training strategies are described as complementary compression approaches within the framework, with their complete empirical evaluation reserved for future work. Experimental results on the MobileNetV2 pipeline show that the quantized model achieves 82.37 percent validation accuracy compared to the 82.20 percent full-precision baseline, reducing model size from 35.34 MB to 5.76 MB, a 6.14x compression ratio with no meaningful accuracy loss. Per-class evaluation confirms that quantization preserves diagnostic performance uniformly across all four tumor categories. These findings demonstrate that lightweight quantized models can deliver clinically viable brain tumor screening in resource-constrained healthcare settings.
Convolutional neural networks (CNNs) have demonstrated encouraging results in image classification tasks. However, the prohibitive computational cost of CNNs hinders the deployment of CNNs onto resource-constrained embedded devices. To address this issue, we propose EdgeCompress, a comprehensive compression framework to reduce the computational overhead of CNNs. In EdgeCompress, we first introduce dynamic image cropping (DIC), where we design a lightweight foreground predictor to accurately crop the most informative foreground object of input images for inference, which avoids redundant computation on background regions. Subsequently, we present compound shrinking (CS) to collaboratively compress the three dimensions (depth, width, and resolution) of CNNs according to their contribution to accuracy and model computation. DIC and CS together constitute a multidimensional CNN compression framework, which is able to comprehensively reduce the computational redundancy in both input images and neural network architectures, thereby improving the inference efficiency of CNNs. Further, we present a dynamic inference framework to efficiently process input images with different recognition difficulties, where we cascade multiple models with different complexities from our compression framework and dynamically adopt different models for different input images, which further compresses the computational redundancy and improves the inference efficiency of CNNs, facilitating the deployment of advanced CNNs onto embedded hardware. Experiments on ImageNet-1K demonstrate that EdgeCompress reduces the computation of ResNet-50 by 48.8% while improving the top-1 accuracy by 0.8%. Meanwhile, we improve the accuracy by 4.1% with similar computation compared to HRank, the state-of-the-art compression framework. The source code and models are available at https://github.com/ntuliuteam/edge-compress