cs.LGApr 26, 2026

Cardiac Stability Theory: An Axiomatically Grounded Framework for Continuous Cardiac Health Monitoring via Smartphone Photoplethysmography

Authors: Timothy OladunniFarouk Ganiyu Adewumi

Organizations: Department of Computer Science, Morgan State University, Baltimore, MD 21251, USA

Abstract

We present Cardiac Stability Theory (CST), an axiomatically grounded framework formally defining cardiovascular health as a stability margin around a cardiac dynamical attractor. From four axioms we derive the Cardiac Stability Index (CSI), a composite scalar in [0,1] integrating the largest Lyapunov exponent, recurrence determinism, and signal entropy via time-delay embedding. The ECG-based model (CSISurrogateV2, CNN-Transformer) achieves R2=0.8788R^2=0.8788, MAE=0.0234=0.0234 on PTB-XL (21,799 recordings). We extend CSI to smartphone PPG via Complementary Domain Transfer (CDT): CSISurrogateV2 generates pseudo-labels for the BUT PPG dataset (48 recordings, 12 subjects), training TinyCSINet (122,849 parameters), achieving MAE=0.0557=0.0557, ρ=0.660ρ=0.660 on the held-out test set (n=1065n=1065 windows) at <30{<}30 ms mobile latency. CDT is validated on BIDMC, Welltory, and RWS-PPG. Paired validation on 5,035 BIDMC windows yields r=0.454r=0.454 (ρ=0.485ρ=0.485, p<10295p<10^{-295}), confirming correlated cardiac stability across modalities. CSI is negatively correlated with age (slope =0.000225= -0.000225 CSI/year, PTB-XL), discriminates atrial fibrillation from normal sinus rhythm (AUROC=0.89=0.89), and is robust under Perturbation Invariance Training (max AUC drop 1.65%). We derive HeartSpan, a longitudinal stability metric relative to population age norms, enabling continuous non-invasive cardiac monitoring from commodity smartphones for longevity tracking and cardiac risk stratification.

Explore similar work

May 11, 2026eess.SP

A Nonlinear Complexity Index for Wearable PPG Cardiovascular Stability: Multiscale Validation, Systematic Evaluation Correction, and Bayesian Parameter Optimization

Cardiovascular stability estimation from wearable photoplethysmography (PPG) requires a principled nonlinear framework, yet major gaps persist in heuristic parameter selection and evaluation protocols that inflate reported performance. We introduce a Stability-Constrained Cardiovascular Stability Index (SCSI) grounded in Cardiac Stability Theory and validate it across 176,742 segments from four heterogeneous PPG datasets at three temporal scales. Cross-dataset analysis demonstrates a large Kruskal-Wallis effect size (eta2 = 0.351, p < 0.001), strong cross-scale consistency (kappa > 0.97), and significant correlation with respiratory rate across 53 ICU records (Spearman r = 0.346, p = 0.011). We identify three evaluation artifacts that inflate heuristic AUC from a true baseline of 0.573 to 0.752: segment-level cross-validation leakage, test-set normalization leakage, and pooled-AUC overweighting that conceals per-patient failure. Correcting these artifacts and applying Bayesian optimization over 15 joint parameters yields SCSI with cross-validation AUC of 0.720. On 18 held-out records, SCSI achieves pooled AUC of 0.757 (95% CI: 0.686-0.828) and negative predictive value of 0.966 for tachypnea screening, while per-record AUC of 0.497 +/- 0.207 is disclosed for transparency. External validation on 42 elective-surgery records yields AUC of 0.621, confirming cross-population generalization. Ablation analysis identifies the nonlinear complexity module as the dominant component. A sparse three-component architecture is proposed as the minimal deployable configuration. The corrected protocol provides a reproducible benchmark for future wearable cardiovascular stability indices.
Timothy Oladunni, Farouk Ganiyu Adewumi
May 10, 2026cs.LG

Biosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model

Cardiovascular disease remains the leading cause of global mortality, yet scalable cardiac monitoring is hindered by the gap between diagnostic-rich ECG and ubiquitous wearable PPG. Bridging this gap requires representations that are compact, transferable across modalities and devices, and deployable without task-specific retraining. Here we introduce biosignal fingerprints: compact latent representations of cardiovascular state derived from a cross-modal foundation model, the Multi-modal Masked Autoencoder (M2AE), trained on over 3.4 million paired ECG and PPG signals. M2AE integrates modality-specific encoders with a shared bottleneck and dual decoders, jointly optimized using reconstruction and cross-modal contrastive objectives, yielding generalizable fingerprints that retain intra- and inter-modality features. Like a biometric fingerprint, these representations uniquely encode an individual's cardiovascular state in a modality-agnostic, privacy-preserving form reusable across clinical tasks without exposing raw waveform data or requiring model retraining. Across 7 downstream tasks, spanning cross-modal reconstruction, cardiovascular disease classification, hypertension detection, mortality prediction, and demographic inference, biosignal fingerprints achieve competitive or superior performance compared to leading domain-specialist foundation models in frozen settings, including an AUROC of 0.974 for five-class CVD classification and 0.877 for hypertension detection, with a maximum improvement of 27.7% in AUROC across 5 classification tasks. Critically, strong performance is maintained with only a single modality, enabling deployment in resource-constrained, single-sensor environments typical of real-world wearable monitoring, with direct implications for continuous cardiovascular monitoring across clinical and consumer health settings.
Zhangdaihong Liu, Chang Liu, Fenglin Liu +4
Aug 7, 2026eess.SP

CFD-Guided Detection of Concept Drift in Multimodal Physiologic Signals

Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration. This paper asks when a model should keep its prediction, change it, or flag uncertainty. We propose a physiologic stability framework, called PECS, that compares changes inside the model with measurable changes in the signal. ECG is treated as the main cardiac signal, photoplethysmography (PPG) adds pulse and vascular information, and respiration is used only when ECG and PPG disagree. We test the framework on PTB-XL at pilot and full scales and on synchronized BIDMC and MIMIC waveform cohorts. The PTB-XL pilot and full- scale analyses selected different domain pairs, and the strongest cross-modal pair also changed across BIDMC and MIMIC, showing that adding every available signal is not always the best choice. PECS outperformed the evaluated drift-detection baseline implementations, reaching drift classification accuracy (DCA) of 0.8786 on expanded BIDMC and 0.9560 on MIMIC. The MIMIC results also showed that respiration can help during disagreement cases, but it should be used selectively rather than as an automatic override. Overall, the results support PECS as a candidate monitoring framework for wearable cardiovascular AI while highlighting the need for scale-aware domain selection and interpretable trust routing
Farouk Ganiyu Adewumi, Timothy Oladunni, Rochak Ghimire +3