cs.CVMay 1, 2026

Learning from Compressed CT: Feature Attention Style Transfer and Structured Factorized Projections for Resource-Efficient Medical Image Analysis

Authors: Shadid YousufS. M. Mahbubur RahmanMohammed Imamul Hassan Bhuiyan

Abstract

The deployment of artificial intelligence in medical imaging is hindered by high computational complexity and resource-intensive processing of volumetric data. Although chest computed tomography (CT) volumes offer richer diagnostic information than projection radiography, their use in AI-based diagnosis remains limited due to the computational burden of processing uncompressed volumetric images (typically stored in NIfTI or DICOM format). Addressing the growing need for low-resource deployment and efficient electronic data transfer, we investigate the utilization of JPEG-compressed chest CT volumes for thoracic abnormality detection. We propose Feature Attention Style Transfer (FAST), a novel distillation framework that transfers both activation patterns and structural relationships from high-fidelity CT representations to a spatiotemporal visual encoder operating on compressed inputs. By combining Gram-matrix-based attention style preservation with dual-attention feature alignment, FAST enables robust feature extraction from degraded volumes. Furthermore, we introduce Structured Factorized Projection (SFP), leveraging Block Tensor Train decomposition as a parameter-efficient alternative to dense projection layers, reducing projection-head parameters by almost half. Our contrastive learning pipeline, CT-Lite, integrates these components with a SigLIP-based multimodal alignment objective. Experiments on CT-RATE, NIDCH, and Rad-ChestCT demonstrate that CT-Lite achieves AUROC within 5-7% of the uncompressed-input baseline across all three datasets, despite operating on compressed inputs with significantly fewer parameters, paving the way for AI-based clinical evaluation under resource constraints.

Explore similar work

Jul 31, 2026cs.CV

ORCA: ORgan-Centroid Aggregation for Training-Free 3D CT Visual Token Compression

A 3D CT scan entering a vision-language model produces a long sequence of visual tokens, often thousands to tens of thousands per volume, and this sequence must be compressed before a language model can consume it. Token compression is well studied in general vision, but little of it targets 3D CT specifically. A common baseline is grid average, which pools regular grid cells and can blend distinct anatomy, lesion, and air into one token. We present \textbf{ORCA} (ORgan-Centroid Aggregation), a token compressor for 3D CT. It merges adjacent tokens with organ guidance and adds a sinusoidal encoding of each region's centroid to preserve spatial layout. This preserves the anatomical information a downstream model needs. ORCA is training-free and plug-and-play, producing an adjustable token set without any model change or text query. We evaluate it across two datasets (CT-RATE and Merlin) and five encoders. The evaluation spans two task types: attribute prediction over five families (size, density, location, texture, and disease) and text generation (visual question answering and report generation). At matched token budgets, ORCA improves consistently over existing compression methods. It shrinks the visual context 64×64\times and its KV-cache 50×50\times, and is 31×31\times faster to process each volume. Code released at https://github.com/renjie-liang/ORCA-3DCT.
Renjie Liang, Zijian Xu, Jinqian Pan +6
Apr 27, 2026cs.CV

SparseContrast: Dynamic Sparse Attention for Efficient and Accurate Contrastive Learning in Medical Imaging

We propose SparseContrast, a new framework that merges dynamic sparse attention with contrastive learning for medical imaging, with a focus on chest X-ray disease detection in low-data settings. Traditional contrastive learning methods rely on dense attention mechanisms, which are computationally expensive and often process redundant regions in medical images. To resolve this, SparseContrast introduces a sparse attention mechanism that selectively concentrates on diagnostically pertinent areas, markedly decreasing computational burden without compromising accuracy. The framework adaptively trims attention maps in the training phase, directed by a compact saliency predictor which concurrently optimizes sparsity and feature quality. This method not only speeds up training and inference by as much as 40% relative to dense attention benchmarks but also boosts diagnostic accuracy by focusing on areas of clinical importance. Moreover, the approach remains indifferent to the selection of backbone architecture, which permits its application to both convolutional and transformer-based models. Experiments show SparseContrast attains comparable or better performance in disease identification tasks with greater efficiency relative to current approaches. The proposed framework delivers a practical approach for implementing contrastive learning in medical imaging settings with limited resources, where computational efficiency and diagnostic accuracy are paramount.
Paarth Prasad, Ruchika Malhotra
Jun 5, 2026cs.CV

DALE-CT: Depth-Aware Foundation Models for Computed Tomography

Recent breakthroughs in self-supervised learning (SSL), such as the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA), alongside successes in integrating visual encoders with language models, have driven the demand for adaptable, high-capacity vision encoders in Computed Tomography (CT). In this work, we explore 2D slice-based architectures as a flexible alternative to native 3D models for processing volumetric CT data. Using the CT-RATE dataset, we trained DALE-CT (Depth-Aware Latent-Euclidean Computed Tomography), a 2D model family built entirely from scratch using LeJEPA, and compared its performance against a continually pre-trained DINOv2 baseline. To enhance representation quality, we developed a novel 3D depth-aware pre-training strategy anchored by dense auxiliary supervision from both automated anatomical masks and human-annotated abnormalities. Under linear probe evaluation with Multiple Instance Learning (MIL) for multi-abnormality detection, the frozen backbone of this dual-supervised model (DALE-CT-2S) achieves a Macro AUROC of 0.833. This performance demonstrates near-parity with state-of-the-art 3D vision-language models, achieved entirely from scratch with significantly less data and no textual supervision. To ensure reproducibility, all training code, evaluation scripts, and model weights have been made publicly available.
Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty +3