cs.CVMay 3, 2026

MedScribe: Clinically Grounded CT Reporting through Agentic Workflows

Authors: Giuseppe A. OrlandoPaolo PapottiMaria A. ZuluagaOlivier HumbertMarco Lorenzi

Abstract

Vision-language models (VLMs) have shown potential for automated radiology report generation, yet existing approaches rely on global embedding compression of volumetric data, often leading to hallucinated findings and limited anatomical grounding in 3D CT imaging. We introduce MedScribe, a hypothesis-driven framework that reformulates report generation as an iterative evidence acquisition process rather than a single-pass encoding task. MedScribe models reporting as a sequential decision process in which a large language model dynamically invokes pathology-specific diagnostic tools to extract localized volumetric features. These structured features are used to query a multidimensional retrieval space aligned with pathology-specific textual evidence. By explicitly accumulating quantitative evidence prior to synthesis, the framework enforces fine-grained grounding and reduces unsupported claims. Without task-specific fine-tuning, MedScribe improves clinical accuracy, factual consistency, and interpretability on CT-RATE and RadChestCT compared to state-of-the-art 2D and 3D VLMs, demonstrating the value of hypothesis-driven reasoning for reliable medical image reporting.

Explore similar work

Apr 16, 2026cs.AI

RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomography

Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.
Mélanie Roschewitz, Kenneth Styppa, Yitian Tao +10
May 29, 2026cs.CV

Generating Reports or Repeating Templates? Measuring and Mitigating Template Collapse in 3D CT Report Generation

Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.
Tom Maye-Lasserre, Yitong Li, Bailiang Jian +3
Jul 7, 2026cs.CV

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone. The most direct opportunity is reducing the time and effort radiologists spend producing reports, a task that requires interpreting images, integrating clinical history and prior studies, and drafting structured findings. We present Harrison.Rad 1.5 (HR1.5), a radiology-specific multimodal large language model that accepts interleaved text and visual inputs and generates structured and unstructured text across plain-film radiology, spanning computed radiography, chest, musculoskeletal, abdominal, spine, and pelvic x-rays, and mammography. HR1.5 is trained through a three-stage pipeline: domain adaptation of a base language model on radiology reports, contrastive vision-encoder training with curriculum-based hard negatives on ~6 million image-report instances, and visual-question-answering fine-tuning on multi-turn conversations. We evaluate it with a Findings-Diagnosis scoring framework that extends RadGraph-XL entity extraction with ontology-based synonym matching and polarity-contradiction detection, benchmarked on RadBench, a simulated FRCR 2B Short Case examination scored against Angoff-method thresholds, ReXGradient, and internal multi-modality datasets. HR1.5 is the only system evaluated to meet the simulated FRCR passing standard and achieves the highest accuracy on closed-format clinical questions, across anatomical regions, on internal multi-body-part and mammography reporting, and on the primary clinically-aligned score for public chest reporting. We further examine explainability and model behaviour, including question-sensitive Grad-CAM heatmaps, attention analysis, and confidence estimation, to support responsible future evaluation toward clinical use, and a framework for clinically grounded assessment of report quality.
Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar +5