MRI-Eval: A Tiered Benchmark for Evaluating LLM Performance on MRI Physics and GE Scanner Operations Knowledge

Authors: Perry E. Radau

Organizations: Department of Radiology, University of Calgary · Child and Adolescent Imaging Research (CAIR) Program · Alberta Children’s Hospital Research Institute · University of Calgary

Abstract

Background: Existing MRI LLM benchmarks rely mainly on review-book multiple-choice questions, where top proprietary models already score highly, limiting discrimination. No systematic benchmark has evaluated vendor-specific scanner operational knowledge central to research MRI practice. Purpose: We developed MRI-Eval, a tiered benchmark for relative model comparison on MRI physics and GE scanner operations knowledge using primary multiple-choice questions (MCQ), with stem-only and primed diagnostic conditions as complementary analyses. Methods: MRI-Eval includes 1365 scored items across nine categories and three difficulty tiers from textbooks, GE scanner manuals, programming course materials, and expert-generated questions. Five model families were evaluated (GPT-5.4, Claude Opus 4.6, Claude Sonnet 4.6, Gemini 2.5 Pro, Llama 3.3 70B). MCQ was primary; stem-only removed options and used an independent LLM judge; primed stem-only tested responses to incorrect user claims. Results: Overall MCQ accuracy was 93.2% to 97.1%. GE scanner operations was the lowest category for every model (88.2% to 94.6%). In stem-only, frontier-model accuracy fell to 58.4% to 61.1%, and Llama 3.3 70B fell to 37.1%; GE scanner operations stem-only accuracy was 13.8% to 29.8%. Conclusion: High MCQ performance can mask weak free-text recall, especially for vendor-specific operational knowledge. MRI-Eval is most informative as a relative comparison benchmark rather than an absolute competency measure and supports caution in using raw LLM outputs for GE-specific protocol guidance.

Explore similar work

May 28, 2026cs.CV

CardioLens: Revealing the Clinical Reality Gap of MLLMs via Multi-Sequence Cardiac MRI Evaluations

Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks. We introduce CardioLens, a leakage-resistant evaluation testbed for multi-sequence Cardiovascular Magnetic Resonance (CMR), constructed from private hospital archives through a rigorous report-to-QA construction and verification pipeline. CardioLens contains 473,896 slices and 13,494 verified QA pairs across 4D Cine, LGE, perfusion, and T2-weighted imaging, and evaluates three stages of CMR interpretation: image understanding, report generation, and disease diagnosis. Across 24 state-of-the-art MLLMs, CardioLens reveals a substantial clinical reality gap: models perform poorly overall, with performance degrading along the real CMR workflow. Confusion analysis further shows a category-collapse failure mode, where models default to frequent abnormal categories rather than distinguishing clinically distinct findings. To rule out MLLM-compatible input construction as the primary cause, we compare random, clinically motivated, and data-driven slice selection protocols under different slice budgets; performance changes only marginally, typically by about 1%. Explicit reasoning prompts also fail to rescue performance, often making models more conservative rather than improving visual evidence use. These results show that current MLLMs remain far from reliable CMR interpretation, where clinical decisions require integrating distributed evidence across sequences, views, and temporal phases. CardioLens provides a clinically grounded testbed for developing next-generation MLLMs toward real-world clinical deployment.
Zixian Su, Hongkai Zhang, Fan Gao +12
May 19, 2026cs.CV

NeuroQA: A Large-Scale Image-Grounded Benchmark for 3D Brain MRI Understanding

We present NeuroQA, a large-scale benchmark for visual question answering in 3D brain magnetic resonance imaging (MRI), with 56,953 QA pairs from 12,977 subjects across 12 datasets. It spans ages 5-104 and five clinical domains: Alzheimer's, Parkinson's, tumors, white matter disease, and neurodevelopment. Unlike prior medical Visual Question Answering (VQA) efforts that operate on 2D slices or rely on narrow diagnostic labels, NeuroQA pairs every item with a full 3D volume. It evaluates 11 clinically grounded reasoning skills across Yes/No, multiple-choice, and open-ended formats. Of the 203 templates, 131 are image-grounded (answerable from a 3-plane viewer) and 72 are image-informed (ground truth from quantitative volumetry or clinical instruments). To remove text-only shortcuts, we apply answer-distribution refinement, reducing closed-format text-only accuracy from >>80% to 44.6%; image necessity is assessed separately through an image-grounding protocol released with the benchmark. A 38-rule deterministic pipeline and two rounds of expert review verify every QA pair against FreeSurfer measurements, metadata, or radiology report fields, with zero same-subject contradictions across templates. We conduct a clinician evaluation in which two clinicians independently assess 100 frozen test items on a three-plane viewer. On closed-format (Yes/No + multiple-choice) test-public items, the best zero-shot vision-language model and a supervised 3D CNN baseline reach 47.5% and 43.7% accuracy respectively, both below the 49.4% text-only majority-template floor. NeuroQA adopts a two-tier release with public QA pairs for open-access datasets and reproducible generation scripts for datasets restricted by data use agreements (DUAs), plus subject-level splits, a held-out private test set, and an online leaderboard.
Mohammad H. Abbasi, Favour Nerrise, Shaurnav Ghosh +12
Jul 1, 2026cs.CL

Clinician-Level Agreement Without Clinical Caution: LLM Evaluator Limits in Medical AI Benchmarking

Open-response evaluation provides stronger clinical validity than multiple-choice benchmarks but creates a scoring bottleneck that motivates automated LLM-asa-Judge approaches. Whether such evaluators replicate clinical calibration and caution, however, remains untested. We introduce MedQADE, the first standardised open-response clinical benchmark for German, a major clinical language lacking native evaluation infrastructure, comprising 3,800 items annotated by ten practising physicians and nine Large Language Model (LLM) evaluators. The top-performing evaluator model, Gemini 3 Flash, reached alignment consistent with the physician ceiling (\k{appa} = 0.694 vs. \k{appa} = 0.709), though wide confidence intervals limit interpretation. Despite this statistical alignment, automated evaluators exhibited near-absent clinical metacognition: physicians scaled abstention with item difficulty, while frontier models assigned definitive scores in every case. We additionally quantified systematic lineage-dependent biases, where models preferentially scored architectural siblings, an effect independent of language. These results show that statistical alignment does not ensure clinical caution, and that evaluator independence requires explicit verification.
William Philipp, Finn Fassbender, Thorsten Langer +11