cs.CVMay 7, 2026

Retina-RAG: Retrieval-Augmented Vision-Language Modeling for Joint Retinal Diagnosis and Clinical Report Generation

Authors: Abdelrahman ZaianSheethal BhatMohamed AbdalkaderAndreas Maier

Abstract

Diabetic Retinopathy (DR) is a leading cause of preventable blindness among working-age adults worldwide, yet most automated screening systems are limited to image-level classification and lack clinically structured reporting. We propose Retina-RAG, a low-cost modular framework that jointly performs DR severity grading, macular edema (ME) detection, and report generation. The architecture decouples a high-performance retinal classifier and a parameter-efficient vision-language model (Qwen2.5-VL-7B-Instruct) adapted via Low-Rank Adaptation (LoRA), enabling flexible component integration. A retrieval-augmented generation (RAG) module injects curated ophthalmic knowledge together with structured classifier outputs at inference time to improve diagnostic consistency and reduce hallucinations. Retina-RAG achieves an F1-score of 0.731 for DR grading and 0.948 for ME detection, substantially outperforming zero-shot Qwen (0.096, 0.732) and MMed-RAG (0.541, 0.641) on a retinal disease detection dataset with captions. For report generation, Retina-RAG attains ROUGE-L 0.438 and SBERT similarity 0.884, exceeding all baselines. The full framework operates on a single consumer-grade GPU, demonstrating that clinically structured retinal AI can be achieved with modest computational resources.

Explore similar work

Apr 19, 2026cs.CV

DREAM: Dynamic Retinal Enhancement with Adaptive Multi-modal Fusion for Expert Precision Medical Report Generation

Automating medical reports for retinal images requires a sophisticated blend of visual pattern recognition and deep clinical knowledge. Current Large Vision-Language Models (LVLMs) often struggle in specialized medical fields where data is scarce, leading to models that overfit and miss subtle but critical pathologies. To address this, we introduce DREAM (Dynamic Retinal Enhancement with Adaptive Multi-modal Fusion), a novel framework for high-fidelity medical report generation that excels even with limited data. DREAM employs a unique two-stage fusion mechanism that intelligently integrates visual data with clinical keywords curated by ophthalmologists. First, the Abstractor module maps image and keyword features into a shared space, enhancing visual data with pathology-relevant insights. Next, the Adaptor performs adaptive multi-modal fusion, dynamically weighting the importance of each modality using learnable parameters to create a unified representation. To ensure the model's outputs are semantically grounded in clinical reality, a Contrastive Alignment module aligns these fused representations with ground-truth medical reports during training. By combining medical expertise with an efficient fusion strategy, DREAM sets a new state-of-the-art on the DeepEyeNet benchmark, achieving a BLEU-4 score of 0.241, and further demonstrates strong generalization to the ROCO dataset.
Nagur Shareef Shaik, Teja Krishna Cherukuri, Dong Hye Ye
May 10, 2026eess.IV

Cross-Modal Semantic-Enhanced Diffusion Framework for Diabetic Retinopathy Grading

Automated grading of diabetic retinopathy (DR) faces several critical challenges: subtle inter-grade visual distinctions in fine-grained lesion patterns, distributional discrepancies induced by heterogeneous imaging devices and acquisition conditions, and the inherent inability of purely visual approaches to exploit clinical semantic knowledge. In this paper, we propose CLIP-Guided Semantic Diffusion (CGSD), a DR grading framework that synergistically integrates vision-language pretraining with diffusion probabilistic modeling. We adopt a domain-specific vision-language model tailored for DR grading as the semantic guidance module and adapt it to the target domain via Low-Rank Adaptation (LoRA), effectively bridging the distributional gap between the pretrained model and the target dataset with only a minimal number of trainable parameters. Building on this foundation, we construct a cross-modal semantic conditioning vector by computing the dot product between image features and the text description features of each DR grade, yielding a joint representation that simultaneously encodes visual content and clinical-grade semantics. This vector serves as the conditioning signal for the diffusion denoising network, replacing the structurally complex dual-branch visual prior employed in existing diffusion-based classification methods. Experiments on the APTOS 2019 dataset demonstrate that the proposed approach achieves an accuracy of 87.5% and a macro-averaged F1 score of 0.731, outperforming a variety of representative methods. Ablation studies further validate the independent contribution of each constituent module.
Yiqun Wang
Apr 28, 2026cs.CV

Toward Multimodal Conversational AI for Age-Related Macular Degeneration

Despite strong performance of deep learning models in retinal disease detection, most systems produce static predictions without clinical reasoning or interactive explanation. Recent advances in multimodal large language models (MLLMs) integrate diagnostic predictions with clinically meaningful dialogue to support clinical decision-making and patient counseling. In this study, OcularChat, an MLLM, was fine-tuned from Qwen2.5-VL using simulated patient-physician dialogues to diagnose age-related macular degeneration (AMD) through visual question answering on color fundus photographs (CFPs). A total of 705,850 simulated dialogues paired with 46,167 CFPs were generated to train OcularChat to identify key AMD features and produce reasoned predictions. OcularChat demonstrated strong classification performance in AREDS, achieving accuracies of 0.954, 0.849, and 0.678 for the three diagnostic tasks: advanced AMD, pigmentary abnormalities, and drusen size, significantly outperforming existing MLLMs. On AREDS2, OcularChat remained the top-performing method on all tasks. Across three independent ophthalmologist graders, OcularChat achieved higher mean scores than a strong baseline model for advanced AMD (3.503 vs. 2.833), pigmentary abnormalities (3.272 vs. 2.828), drusen size (3.064 vs. 2.433), and overall impression (2.978 vs. 2.464) on a 5-point clinical grading rubric. Beyond strong objective performance in AMD severity classification, OcularChat demonstrated the ability to provide diagnostic reasoning, clinically relevant explanations, and interactive dialogue, with high performance in subjective ophthalmologist evaluation. These findings suggest that MLLMs may enable accurate, interpretable, and clinically useful image-based diagnosis and classification of AMD.
Ran Gu, Benjamin Hou, Mélanie Hébert +5