cs.CLMay 8, 2026

Uncertainty-Aware Structured Data Extraction from Full CMR Reports via Distilled LLMs

Authors: Yi YuParker MartinZhenyu BuYixuan LiuYi-Yu ZhengOrlando SimonettiYuchi HanYuan Xue

Organizations: †The Ohio State University · ‡NetMind.AI

Abstract

Converting free-text cardiac magnetic resonance (CMR) reports into auditable structured data remains a bottleneck for cohort assembly, longitudinal curation, and clinical decision support. We present CMR-EXTR, a lightweight framework that converts free-text CMR reports into structured data and assigns per-field confidence for quality control. A teacher-student distillation pipeline enables fully offline inference while limiting manual annotation. Uncertainty integrates three complementary principles -- distribution plausibility, sampling stability, and cross-field consistency -- to triage human review. Experiments show that CMR-EXTR achieves 99.65% variable-level accuracy, demonstrating both reliable extraction and informative confidence scores. To our knowledge, this is the first CMR-specific extraction system with integrated confidence estimation. The code is available at https://github.com/yuyi1005/CMR-EXTR.

Explore similar work

Jun 5, 2026cs.AI

Automatic Extraction of Structured Information from Brain MRI Reports Using an Open-Weight Large Language Model

Objectives: Automatic data extraction from free-text radiology reports enables large-scale research, but few studies assessed the performance of large language models (LLMs) on Dutch neuroradiology reports. Methods: We analyzed 947 brain MRI reports from a tertiary memory clinic (2016-2021), authored by consultant neuroradiologists. Trained medical students annotated thirty variables; 100 reports were double-annotated to assess inter-rater reliability. We evaluated the performance of the open-weight LLM LLaMA 3.1 using different languages (Dutch vs. English translation) and few-shot prompting with different example selection strategies. Performance was evaluated using balanced accuracy for categorical variables, accuracy and mean absolute error for counts, and text similarity for free-text. Metrics were computed across 10 random splits of the 947 reports. Results: LLaMA 3.1 demonstrated high zero-shot performance for visual rating scores (mean [95%-CI]): Medial Temporal Atrophy: 90% [77-100%] on the left and 96% [94-99%] on the right, Global Cortical Atrophy: 87% [83-91%], and Fazekas: 94% [93-96%]. Microbleed mentions were detected with 93% accuracy [92-95%] and infarct mentions with 82% [80-84%]. Text similarity for lesion location reached 0.95 [0.95-0.96]. Performance was lower for numerical variables: 80% [78-82%] for the number of microbleeds and 66% [63-68%] for infarcts. English translation yielded comparable results. Few-shot prompting improved performance for numerical variables, achieving 92% [90-93%] for microbleeds and 81% [77-85%] for infarcts using structural similarity-based selection. Conclusion: LLaMA 3.1 shows strong potential for extracting data from Dutch neuroradiology reports. Few-shot prompting enhances performance for numerical variables, whereas challenges remain for location-specific variables.
Kaouther Mouheb, Amos Pomp, Antoine Manenti +9
May 28, 2026cs.CV

CardioLens: Revealing the Clinical Reality Gap of MLLMs via Multi-Sequence Cardiac MRI Evaluations

Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks. We introduce CardioLens, a leakage-resistant evaluation testbed for multi-sequence Cardiovascular Magnetic Resonance (CMR), constructed from private hospital archives through a rigorous report-to-QA construction and verification pipeline. CardioLens contains 473,896 slices and 13,494 verified QA pairs across 4D Cine, LGE, perfusion, and T2-weighted imaging, and evaluates three stages of CMR interpretation: image understanding, report generation, and disease diagnosis. Across 24 state-of-the-art MLLMs, CardioLens reveals a substantial clinical reality gap: models perform poorly overall, with performance degrading along the real CMR workflow. Confusion analysis further shows a category-collapse failure mode, where models default to frequent abnormal categories rather than distinguishing clinically distinct findings. To rule out MLLM-compatible input construction as the primary cause, we compare random, clinically motivated, and data-driven slice selection protocols under different slice budgets; performance changes only marginally, typically by about 1%. Explicit reasoning prompts also fail to rescue performance, often making models more conservative rather than improving visual evidence use. These results show that current MLLMs remain far from reliable CMR interpretation, where clinical decisions require integrating distributed evidence across sequences, views, and temporal phases. CardioLens provides a clinically grounded testbed for developing next-generation MLLMs toward real-world clinical deployment.
Zixian Su, Hongkai Zhang, Fan Gao +12
Sep 20, 2026eess.IV

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.
Omer Burak Demirel, Kelly K. Horst, Alessio Perazzolo +15