The scarcity of high-quality imaging data for coronary angiography (CAG) stenosis limits the clinical translation of automated stenosis detection. Synthetic stenosis data provides a practical avenue to augment training sets, improving data quality, diversity, and distributional coverage, and enhancing detection precision and generalization. However, diffusion-based editing commonly relies on soft guidance in a noise-initialized reverse process, offering limited pixel-level precision and structure preservation. We propose the OT-Bridge Editor, which reframes localized editing as a constrained entropic optimal transport (OT) problem and leverages geometric information to steer the generation path, enabling stronger geometric control. Extensive experiments show that our synthesized angiograms consistently improve downstream stenosis detection, yielding substantial relative gains of 27.8% on the public ARCADE benchmark and 23.0% on our multi-center dataset, supported by consistent qualitative results.
Multi-view reasoning in coronary X-ray angiography is inherently a cross-projection geometric problem, yet automated report generation in this setting remains largely unexplored. The 3D vascular topology leads to projection-dependent branch overlap and foreshortening, rendering single-view modeling fundamentally incomplete and unstable for lesion localization and stenosis grading. Although multi-view fusion appears promising, learning anatomically consistent fusion from real angiograms is impeded by a critical limitation: cross-view alignment is unobservable and cannot be explicitly supervised. Consequently, conventional fusion relies on implicit correlations rather than verified anatomical correspondence. We address this by reformulating multi-view stenosis reporting as an alignment-constrained aggregation problem. A controllable synthetic angiography generation strategy is introduced to expose geometry-derived patch-level correspondence supervision unavailable in real data. An anatomy-correspondence module learns cross-view correspondence matrices that explicitly align auxiliary features within the main-view coordinate space prior to fusion, thereby constraining evidence aggregation to anatomically consistent regions. Experiments on synthetic data and zero-shot transfer to real angiograms show that this alignment-constrained design improves correspondence consistency and structured stenosis reporting compared to single-view modeling and conventional multi-view fusion methods. The code will be publicly available upon publication.
Coronary guidewire endpoint localization is a fundamental capability for computer-assisted PCI, and its importance increases as robot-assisted PCI is progressively adopted to reduce operator radiation exposure. However, the scarcity of annotated CAG images with guidewires and the limited adaptability of existing guidewire synthesis models remain key bottlenecks for guidewire endpoint localization. To address this issue, we propose VDSB-GWSyn, a Diffusion Schrödinger Bridge (DSB) model-based framework, enabling synthesis of controllable, high-fidelity guidewire samples under complex anatomical backgrounds. VDSB-GWSyn first uses our shape prior algorithm to learn the basic guidewire geometry. It then generates guidewire masks under constraints imposed by the vessel segmentation masks and outputs the corresponding endpoint coordinates. Finally, it synthesizes realistic guidewire samples on real CAG images using DSB conditioned with SPADE. Experimental results show that the guidewire samples synthesized by VDSB-GWSyn achieve favorable ROI-FID and ROI-KID, as well as high IPR scores. In addition, incorporating our synthesized data for synthetic pre-training followed by real fine-tuning substantially improves downstream guidewire endpoint localization, reducing MPE from 16.01px to 7.71px and increasing PCK at 3~px from 52.63% to 86.27%, leading to more clinically reliable deployment of robot-assisted guidewire delivery systems. Moreover, the core design philosophy of controllable device synthesis with strict background preservation and anatomical feasibility constraints has the potential to transfer to other interventional device perception tasks where annotated data are scarce.
Accurate correspondence matching across multiple angiographic views is the prerequisite for 3D coronary reconstruction and interventional guidance. However, the development of robust deep learning models for this task has been stifled by a fundamental data bottleneck. Obtaining ground truth for matching tasks in angiography pairs is prohibitively expensive and hard to scale. To overcome this barrier, we introduce a physically-grounded data generation framework that synthesizes high-fidelity Digital Reconstructed Radiographs (DRRs) from 3D Coronary CT Angiography (CCTA) volumes. Our framework generates dense, highly accurate 3D-to-2D projection labels by simulating realistic C-arm acquisition geometry on patient anatomy at zero human cost. Leveraging this dense supervision, we propose a Geometry-Informed Matching Module (GIMM) that integrates global feature and anatomical structure into correspondence learning. Unlike real angiography where assessment relies on subjective human annotation, our dataset provides 2D correspondence labels with paired images, allowing human-free evaluation. We comprehensively evaluate our method on the proposed CT-derived DRR dataset and demonstrate improvements over other matching baseline models.