cs.CVMay 13, 2026

Bridging the Rural Healthcare Gap: A Cascaded Edge-Cloud Architecture for Automated Retinal Screening

Authors: Nishi DoshiShrey Shah

Organizations: University of Southern California · Los Angeles, USA

Abstract

Diabetic Retinopathy (DR) is one of the leading causes of preventable blindness, yet rural regions often lack the specialists and infrastructure needed for early detection. Although cloud-based deep learning systems offer high accuracy, they face significant challenges in these settings due to high latency, limited bandwidth, and high data transmission costs. To address these challenges, we propose a two-tier edge-cloud cascade on the public APTOS 2019 Blindness Detection dataset. Tier 1 runs a lightweight MobileNetV3-small model on a local clinic device to perform a binary triage between Referable DR (Classes 2-4) and Non-referable DR (Classes 0-1). Tier 2 runs a RETFoundDINOv2 model in the cloud for ordinal severity grading, but only on the subset of images flagged as referable by Tier 1. On a stratified APTOS test split of 733 images, Tier 1 reaches 98.99% sensitivity and 84.37% specificity at a validation-tuned high-sensitivity threshold. The default cascade forwards 49.52% of test images to Tier 2, reducing cloud calls by 50.48% relative to using a cloud-based model for all images. In the deployed 4-class output space (Class 0-1 / Class 2 / Class 3 / Class 4), the cascade obtains 80.49% accuracy and 0.8167 quadratic weighted kappa; the cloud-only baseline obtains 80.76% accuracy and 0.8184 quadratic weighted kappa. On APTOS, the cascade cuts cloud use by about half with a modest drop in grading performance. Index Terms: Diabetic Retinopathy, Edge-Cloud Cascade, MobileNetV3-small, RETFound-DINOv2, Retinal Screening, tele-ophthalmology

Explore similar work

Jul 22, 2026eess.IV

PRISM-DR: Per-lesion Retinal Inference with Specialist Models for Diabetic Retinopathy

Diabetic retinopathy is a leading cause of preventable blindness; its early lesions are small, low contrast, and easily missed in manual screening. Most automated detectors handle the four non-proliferative DR lesions: microaneurysms, hemorrhages, hard exudates, and soft exudates, with a single multi-class model, even though these lesions differ sharply in size, color, morphology, and prevalence, so a shared model favors common, easy classes over rare, difficult ones. We present PRISM-DR, a lesion-specific pipeline that trains one single-class detector per lesion, each with its own configuration. From a raw fundus image, the pipeline applies region of interest cropping, fundus-specific preprocessing, four parallel YOLO detectors, tiling, per-lesion ensembling of five cross-validation folds, and an inter-lesion suppression step that resolves overlaps by physical lesion size and clinical priority rather than confidence. Per lesion, the best of five YOLO generations is selected, and augmentation is tuned by Bayesian optimization. Trained on IDRiD with stratified five-fold cross-validation, the system reaches a test mAP50 of 0.527 and F1 of 0.529, highest AP50 on hard exudates with 0.561. Without fine-tuning, the models transfer well where the imaging scale is close to IDRiD and degrade as field of view and resolution depart. These modest absolute results reflect a small single-source training set and a difficult task; however, treating each lesion as a separate detection problem is a practical alternative to a single multi-class model.
Zübeyr Özeren, Tansel Uyar
May 7, 2026cs.CV

Retina-RAG: Retrieval-Augmented Vision-Language Modeling for Joint Retinal Diagnosis and Clinical Report Generation

Diabetic Retinopathy (DR) is a leading cause of preventable blindness among working-age adults worldwide, yet most automated screening systems are limited to image-level classification and lack clinically structured reporting. We propose Retina-RAG, a low-cost modular framework that jointly performs DR severity grading, macular edema (ME) detection, and report generation. The architecture decouples a high-performance retinal classifier and a parameter-efficient vision-language model (Qwen2.5-VL-7B-Instruct) adapted via Low-Rank Adaptation (LoRA), enabling flexible component integration. A retrieval-augmented generation (RAG) module injects curated ophthalmic knowledge together with structured classifier outputs at inference time to improve diagnostic consistency and reduce hallucinations. Retina-RAG achieves an F1-score of 0.731 for DR grading and 0.948 for ME detection, substantially outperforming zero-shot Qwen (0.096, 0.732) and MMed-RAG (0.541, 0.641) on a retinal disease detection dataset with captions. For report generation, Retina-RAG attains ROUGE-L 0.438 and SBERT similarity 0.884, exceeding all baselines. The full framework operates on a single consumer-grade GPU, demonstrating that clinically structured retinal AI can be achieved with modest computational resources.
Abdelrahman Zaian, Sheethal Bhat, Mohamed Abdalkader +1
Jul 28, 2026cs.LG

OrthKD: Extracting Generalized Clinical Knowledge from Heterogeneous Teachers for Lightweight Deployment

Deploying diabetic retinopathy (DR) screening models in primary care requires edge-efficient systems that remain accurate, safe, and reliable under domain shift. Multi-teacher knowledge distillation (KD) is a natural compression strategy, but existing approaches largely assume that all teachers provide equally trustworthy supervision. In our setting, this assumption fails: a strong CNN teacher (EfficientNet-B3, 0.876 QWK) and a weaker Transformer teacher (Swin-Base, 0.830 QWK) are complementary, yet the Transformer's logits can still mislead the student. We therefore propose OrthKD, a selective-trust distillation framework that transfers full supervision from the strong CNN, uses feature-only distillation from the weak ViT, and enforces orthogonality between teacher-specific student projections to encourage complementary rather than redundant evidence. This design preserves local lesion precision, injects global structural context, and improves robustness to distribution shift. On 132,049 retinal images, a 5.4M-parameter MobileNetV3 student reaches 0.885 QWK on EyePACS and improves zero-shot Messidor-2 performance from 0.507 to 0.728 QWK, while also achieving strong referral AUC and calibration. These results show that selectively distilling heterogeneous teachers can enable practical DR screening on resource-constrained devices.
Yi Xu, Cheng Chen, Mufan Cao