cs.LGMay 23, 2026

Synheart Capacity: A Theory-Driven Physiological Representation of Cognitive Capacity Dynamics from Wearable Signals

Authors: Yisak DebeleHenok AdemtewIsrael Goytom

Organizations: Synheart AI, Vancouver, Canada

Abstract

Human cognitive performance is constrained by limited mental resources, yet continuous computational estimation of cognitive capacity dynamics remains an open challenge. We propose a theory-driven multimodal learning framework that models capacity-related cognitive state as a two-dimensional physiological representation defined by voluntary resource allocation (mental effort) and overload-related strain (stress). The proposed architecture combines dual-stream encoding of cardiac (IBI/HRV) and electrodermal (EDA) signals with late fusion and task-specific output heads that independently estimate probabilistic effort and stress states. Evaluation on the SWELL-KW dataset using strict leave-one-subject-out cross-validation demonstrates cross-individual generalization (stress: 70.0% balanced accuracy; effort: 72.2%), with significant gains from multimodal integration and theory-guided supervision. Rather than collapsing physiological dynamics into a single workload label, the proposed effort--stress state-space enables structured differentiation between distinct cognitive regimes, including productive engagement and overload-related strain. Predicted state trajectories exhibit significant demand-sensitive shifts under controlled workload manipulations, with effort and stress responding differentially across interruption and time-pressure conditions. These results suggest that physiologically grounded multidimensional state representations may provide a foundation for adaptive systems capable of continuous capacity-aware monitoring and human-centered interaction.

Explore similar work

May 21, 2026cs.LG

CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment

Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
Amir Mousavi, Erfan Nourbakhsh, Mohammad Sadegh Sirjani +5
Jun 11, 2024cs.HC

Wearable Device-Based Real-Time Monitoring of Physiological Signals: Evaluating Cognitive Load Across Different Tasks

This study employs cutting-edge wearable monitoring technology to conduct high-precision, high-temporal-resolution (1-second interval) cognitive load assessment on electroencephalogram (EEG) data from the FP1 channel and heart rate variability (HRV) data of secondary vocational students. By jointly analyzing these two critical physiological indicators, the research delves into their application value in assessing cognitive load among secondary vocational students and their utility across various tasks. The study designed two experiments to validate the efficacy of the proposed approach: Initially, a random forest classification model, developed using the N-BACK task, enabled the precise decoding of physiological signal characteristics in secondary vocational students under different levels of cognitive load, achieving a classification accuracy of 97%. Subsequently, this classification model was applied in a cross-task experiment involving the National Computer Rank Examination (Level-1), demonstrating the method's significant applicability and cross-task transferability in diverse learning contexts. Conducted with high portability, this research holds substantial theoretical and practical significance for optimizing teaching resource allocation in secondary vocational education, as well as for cognitive load assessment methods and monitoring. Currently, the research findings are undergoing trial implementation in the school.
Ling He, Yanxin Chen, Wenqi Wang +2
Aug 13, 2026cs.LG

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Hamza Shafiq, Hung Manh Pham, Bin Zhu +3