Stiffness Optimization for Concentrated Bending in Magnetically Actuated Catheters: Maintaining Steerability under Gradient Stiffness

Authors: Jiewen Tan, Junnan Xue, Shing Shin Cheng, Shuang Song, Erli Lyu, Jiaole Wang

Organizations: Harbin Institute of Technology (Shenzhen), Shenzhen, China, 518055 · Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong · Faculty of Applied Science, Macao Polytechnic University, Macao

Abstract

Achieving both efficient pushability (propulsion transmission) and proximally concentrated bending for steerability is challenging for magnetically actuated soft catheters: higher axial/bending stiffness improves force transmission but reduces steerability, whereas lower stiffness enables large, proximally concentrated bending yet increases kinking/buckling risk under compressive push loads. To address this trade-off, we propose a stiffness-optimized multi-segment magnetically actuated catheter (SO-MAC) that integrates a decoupled steering-advancement mechanism with a gradient-stiffness architecture. The SO-MAC concentrates bending about a stable proximal pivot during advancement while the distal section passively self-straightens to transmit propulsion, aided by the optimized stiffness distribution and elastic recovery of the spring backbone against friction-induced kinking/buckling. Over 0−180∘0{-}180^{\circ} combined steering and advancement, the pivot remained stable and the distal tip advanced near-straight toward the target direction. A 1.5 mm-diameter SO-MAC achieved up to 180∘180^{\circ} steering with a 3 mm bending radius at its 10 mm tip, with an average shape error of 1.39±0.561.39 \pm 0.56 mm and a steering-pivot error of 0.35±0.100.35 \pm 0.10 mm. Visual feedback control in a bronchial phantom further confirmed robust navigation through highly curved, bifurcating paths.

Explore similar work

Jul 23, 2026eess.SY

Interaction Dynamics Modeling and Predictive Control for Safe Steerable Catheter--Tissue Interaction

Safe steerable catheter control is fundamentally a problem of interaction dynamics: the tip must follow a planned motion, remain compliant against moving tissue, reject friction and hysteresis, and respect a clinically meaningful never-exceed contact-force bound. We formulate catheter--tissue interaction dynamics in the scalar tip-normal coordinate of a single-segment single-tendon catheter. A partial-physics feedforward cancels only the reliable nominal bending dynamics, exposing a configuration-invariant linear interaction-dynamics model whose input gain varies through the scalar catheter inertia. A predictive optimizer then regulates this interaction state subject to hard contact-force, tendon-force, and curvature constraints. An augmented Kalman filter compresses contact, friction, and modeling error into one sensor-free disturbance state, giving nominal offset-free regulation in free space while leaving force safety to the explicit constraint. The unconstrained and disturbance-free limit recovers classical catheter impedance as a special realization of the same interaction dynamics, rather than as the main design object. In a MuJoCo distributed-compliance simulation of an eight-link tendon-driven catheter, disturbance augmentation cuts free-space approach error by 90%, and only the force-constrained predictive interaction-dynamics controller reconciles tracking with the 0.5,N bound: the unconstrained controller drives contact force to 0.60,N against a penetrating target, while the constrained one holds 0.47,N at identical tracking. These results show that offset-free motion regulation and contact-force safety are coupled interaction-dynamics objectives, and that the explicit predictive constraint resolves their tension under stiff tissue contact. The bound also holds under 0.50.5,mm, 1.21.2,Hz cardiac motion. Hardware validation is future work.
Yongyan Cao
Jul 28, 2026cs.RO

Modular Robotic Catheters for Endovascular Aneurysm Repair

Fenestrated/Branched endovascular aneurysm repair (FEVAR/BEVAR) require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta, before deploying stent grafts to alleviate pressure on the aneurysm. Previous clinical studies suggests that surgeons continue to struggle with vessel access using standard commercial instruments, prolonging the procedural time and inducing further complications. In this work, we present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity. 2) An expandable, modular tendon-driven actuation platform that can accommodate for the redundancies introduced in our system. To fabricate the catheter, we capitalized on thermal fiber drawing, a technique that creates high-aspect ratio devices at scale, and processed the catheter with laser micro-machining to soften its tip. We evaluated the system using simulations, where we investigated the catheter's bending stiffness, then its steerability with in-vitro experiments in vascular phantoms. This handheld, robotic steerable catheter system has the potential to shorten the length of future endovascular surgeries, and give clinicians the tools to resolve challenging clinical cases.
Alex Ranne, Jinshi Zhao, Ali Anil Demircali +5
Apr 20, 2026cs.RO

Muscle-inspired magnetic actuators that push, pull, crawl, and grasp

Functional magnetic composites capable of large deformation, load bearing, and multifunctional motion are essential for next-generation adaptive soft robots. Here, we present muscle-inspired magnetic actuators (MMA), additively manufactured from a thermoplastic/permanent magnet polyurethane/Nd2Fe14B (TPU/MQP-S) composite using laser powder bed fusion (LPBF). By tuning the laser-energy scale between 1.0 and 3.0, both mechanical stiffness and magnetic response are precisely controlled: the tensile strength increases from 0.28 to 0.99 MPa while maintaining 30-45% elongation at break. This process enables the creation of 0.5 mm-thick flexural hinges, which reversibly bend and fold under moderate magnetic fields without damage. Two actuator types are reported showing the system versatility. The elongated actuator with self-weight of 1.57 g, magnetized in its contracted state, achieves linear contraction under a 500 mT field, lifting 50 g (32x its own weight) and sustaining performance over at least 50 cycles. Equipped with anisotropic frictional feet, it supports movement of a magnetic crawling robot that achieves up to 100% locomotion success on textured substrates. The expandable actuator exhibits reversible opening and closing under a 300 mT field, reliably grasping and releasing different objects, including soft berries and rigid 3D printed geometries. It can also anchor in a tube while holding suspended 50 g loads. This work demonstrates a LPBF-based strategy to program both stiffness and magnetization within a single material system, enabling remotely driven, reconfigurable, and fatigue-resistant soft actuators. The approach opens new possibilities for force controlled, multifunctional magnetic soft robots for adaptive gripping, locomotion, and minimally invasive manipulation of biomedical tools.