physics.med-phMay 18, 2026

Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T

Authors: Julius ÅkessonIulius DragonuEinar HeibergTina YaoRebecca BakerRuta VirsinskaiteDaniel KnightVivek Muthurangu+1 more

Organizations: 1: Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, United Kingdom. · 2: Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden. · 3: Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden. · 4: Research & Collaborations GBI, Siemens Healthcare Ltd, Camberley, United Kingdom.

Abstract

Purpose: Real-time (RT) bSSFP MRI enables fast free-breathing cardiovascular imaging but requires 10-16 slices for functional assessment, resulting in prolonged scan times. Simultaneous multi-slice (SMS) imaging can reduce acquisition time but when combined with non-Cartesian trajectories, it relies on iterative reconstructions that preclude online use. This study investigates deep artifact suppression to facilitate rapid, online reconstruction of RT-SMS. Methods: A spiral bSSFP SMS RT sequence with two simultaneously acquired slices was implemented at 1.5 T. Reconstruction used slice separation in k-space, followed by deep artifact suppression in image space using a 3D U-Net. Ten healthy volunteers were imaged. RT-SMS image quality and reconstruction time were compared between deep artifact suppression and compressed sensing (CS) reconstructions. Left (LV) and right (RV) ventricular volumes at end diastole (EDV) and end systole (ESV) and LV mass (LVM) were compared between RT-SMS with deep artifact suppression and reference-standard breath-hold (BH) imaging. Results: The RT-SMS acquisition was ~13x faster than BH imaging (15 s vs 3 min 15 s). RT-SMS reconstruction using deep artifact suppression was ~50x faster than CS (30 s vs 24 min 55 s). Deep artifact suppression consistently outperformed CS in quantitative and qualitative image quality (p<0.001). Functional agreement between BH and RT-SMS with deep artifact suppression was good (LVEDV: -7.5 +/- 6.8 ml, LVESV: -0.9 +/- 4.2 ml, RVEDV: -6.4 +/- 8.4 ml, RVESV: 0.2 +/- 10.7 ml, LVM: -10.3 +/- 11.0 g). Conclusion: Online deep artifact suppression reconstruction for RT-SMS bSSFP CMR enables free-breathing short-axis coverage with a substantial reduction in acquisition and reconstruction time while maintaining diagnostic image quality.

Explore similar work

May 20, 2026eess.IV

Motion-Robust Deep Reconstruction for Free-Breathing Cardiac Cine MRI

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who cannot reliably hold their breath. Free-breathing radial acquisitions can alleviate these limitations, but robust reconstruction at high acceleration remains challenging due to prominent streak artifacts. To address these limitations, we propose Cine-DL, a clinically oriented framework that couples targeted k-space preprocessing with fast, model-based deep reconstruction. In this pipeline, raw free-breathing radial data undergo retrospective cardiac binning and respiratory gating to resolve cardiac phases and discard motion-corrupted spokes. We then introduce Streak Optimized Coil Compression (SOC), which explicitly preserves cardiac signals while suppressing peripheral interference that typically drives the streak artifacts. The resulting 2D+t cine series is reconstructed with an unrolled network that alternates a ResNet proximal operator with physics-based data consistency updates solved via conjugate gradient. We further employ a memory-efficient training strategy that reduces peak memory usage. We evaluate Cine-DL on free-breathing volunteer data against established baselines (k-t SENSE and iGRASP) and demonstrate clinical translation via hospital deployment on newly acquired patient data. Our experiments show that Cine-DL consistently improves quantitative metrics and visual fidelity, supporting a practical route toward routine, time-sensitive clinical adoption of free-breathing cine MRI.
Mahmut Yurt, Kanghyun Ryu, Zhitao Li +8
Aug 10, 2026cs.CV

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Mojtaba Safari, Shansong Wang, Zach Eidex +4
Aug 10, 2026cs.CV

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.
Vladyslav Gapyak, Thomas März, Andreas Weinmann