cs.CVAug 10, 2026

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

Authors: Vladyslav GapyakThomas MärzAndreas Weinmann

Organizations: Institute for the Protection of Terrestrial Infrastructures, German Aerospace Center (DLR), Sankt Augustin, Germany · Hochschule Darmstadt, Schöfferstr. 3, 64295, Darmastdt, Germany · Data Science Institute, European University of Technology, European Union · Algorithms for Computer Vision, Imaging and Data Analysis Lab, Technische Hochschule Würzburg-Schweinfurt, Ignaz-Schön-Straße 11, 97421 Schweinfurt, Germany

Abstract

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.

Explore similar work

Jul 7, 2026cs.CV

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.
Lihua Wei, Huatong Gao, Jia Gong +4
May 12, 2026cs.CV

Beyond MMSE: Enhancing PnP Restoration with ProxiMAP

Plug-and-Play (PnP) methods have become standard tools for solving imaging inverse problems by replacing the intractable maximum a posteriori (MAP) denoiser with the MMSE one. While this mismatch has been widely treated as unavoidable, recent works have sought to close this gap by targeting the MAP with diffusion-model scores. We show this is problematic in practice: learned scores do not match the true ones, so MAP-targeting iterations converge to cartoon-like images rather than realistic ones, and better results are obtained by stopping short of convergence. We turn this observation into a design principle and introduce ProxiMAP, an iterative MAP approximation whose noise schedule keeps the iterate's residual noise matched to the denoiser's training noise. This keeps the denoiser in-distribution where its score is reliable, and yields implicit early stopping that avoids the failure mode above. ProxiMAP is a modular drop-in replacement for MMSE denoisers in standard PnP algorithms and consistently sharpens reconstructions across deblurring, inpainting, super-resolution, and phase retrieval. Building on the same principle, we propose a hybrid variant that applies ProxiMAP only in the late iterations of PnP, where the denoiser is most reliable -- matching or exceeding the full-replacement variant at a fraction of the cost.
Kenta Vert, Giacomo Meanti, Scott Pesme +2
Jun 13, 2026cs.CV

Physics-Driven Zero-Shot MRI Reconstruction with Non-local Image Priors

Zero-Shot Self-Supervised Learning (ZS-SSL) has emerged as a promising paradigm for accelerated Magnetic Resonance Imaging (MRI) reconstruction, eliminating the reliance on fully-sampled external datasets. However, learning solely from a single under-sampled scan suffers from supervision scarcity and optimization instability, often leading to overfitting or artifacts. To address these challenges, we propose a robust physics-driven ZS-SSL framework that synergizes physical consistency with image-domain non-local priors. Our method introduces three core innovations: (1) a Coil Sensitivity Map (CSM)-Guided Dynamic Repository, which stabilizes the training trajectory by filtering physically inconsistent artifacts based on coil sensitivity constraints; (2) a SPIRiT-based regularization, which enforces k-space self-consistency via a learned correlation kernel and stochastic masking; (3) a Non-Local Self-Similarity (NSS) Pixel Bank, which leverages the high-fidelity reference established by the former modules to explicitly mine non-local anatomical similarities, thereby augmenting supervision in the image domain. Extensive experiments on the FastMRI dataset demonstrate that our approach achieves state-of-the-art performance, particularly under high acceleration factors, effectively bridging the gap between zero-shot learning and supervised methods. The code is available at https://github.com/Zolento/NS-SSL.
Lingtong Zhang, Wenlei Li, Mu He +2