Astra: a generalizable report generation foundation model for 3D computed tomography
Authors: Zhuhao Wang, Fang Chen, Chaohui Yu, Zihan Li, Yuchao Zheng, Jing Wang, Xuan Yang, Jia Guo, +14 more
Organizations: School of Biomedical Engineering, Tsinghua University · School of Biomedical Engineering, Shanghai Jiao Tong University · DAMO Academy, Alibaba Group · Hupan Laboratory · Department of Radiology, The First Affiliated Hospital, Zhejiang University School of Medicine · Department of Radiology, Guizhou Provincial People’s Hospital · Department of Radiology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine · College of Computer Science and Technology, Zhejiang University
Abstract
Interpreting computed tomography (CT) requires review of hundreds of volumetric slices and remains time-intensive and expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training difficult. Here we present Astra, a generalizable CT report generation foundation model developed on 90,678 thoracoabdominal CT-report pairs collected from five sites worldwide (CTRgDB), comprising 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluated on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 38.4% average improvement in fine-grained diagnostic metrics (P<0.001). Deployed at external clinical sites without any site-specific fine-tuning, Astra accelerated chest report drafting by 29.6% and improved abdominal report completeness by 11.3% among junior and mid-level radiologists (P<0.001). Furthermore, Astra demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare. The code for Astra is publicly available at https://github.com/zh-Wang-Med/Astra.
Automated chest CT report generation remains challenging because clinically faithful reporting requires both whole-volume understanding and accurate description of localized anatomical findings. Here we developed and retrospectively evaluated MonteRET, a region-aware retrieval-enhanced framework for generating chest CT findings sections. MonteRET integrates global CT features with region-level anatomical representations, retrieves clinically relevant knowledge using predicted medical conditions and region-level vision-language alignment, and refines initial reports through a knowledge-guided report rewriting agent. We trained our model on a public cohort with 24,128 CT scans from RadGenome-ChestCT. We evaluated MonteRET on the public RadGenome-ChestCT test set of 1,564 CT scans and an external cohort of 82 CT scans from NewYork-Presbyterian/Weill Cornell Medical Center. MonteRET improved report quality, semantic similarity, and clinical efficacy compared with a matched baseline and several state-of-the-art methods. Gains were most pronounced for recall, suggesting fewer omitted findings. Human expert evaluation by radiology residents also favored MonteRET.
Vision-language models (VLMs) have shown potential for automated radiology report generation, yet existing approaches rely on global embedding compression of volumetric data, often leading to hallucinated findings and limited anatomical grounding in 3D CT imaging. We introduce MedScribe, a hypothesis-driven framework that reformulates report generation as an iterative evidence acquisition process rather than a single-pass encoding task. MedScribe models reporting as a sequential decision process in which a large language model dynamically invokes pathology-specific diagnostic tools to extract localized volumetric features. These structured features are used to query a multidimensional retrieval space aligned with pathology-specific textual evidence. By explicitly accumulating quantitative evidence prior to synthesis, the framework enforces fine-grained grounding and reduces unsupported claims. Without task-specific fine-tuning, MedScribe improves clinical accuracy, factual consistency, and interpretability on CT-RATE and RadChestCT compared to state-of-the-art 2D and 3D VLMs, demonstrating the value of hypothesis-driven reasoning for reliable medical image reporting.
Giuseppe A. Orlando, Paolo Papotti, Maria A. Zuluaga +2
Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.