cs.CVJun 3, 2026

Multi-Granularity 3D Kidney Lesion Characterization from CT Volumes

Authors: Renjie LiangZhengkang FanJinqian PanChenkun SunJiang BianRussell TerryJie Xu

Abstract

Radiology reports describe kidney lesions by type, size, enhancement, and attenuation, yet existing 3D methods predict only at the patient or organ level. We reformulate kidney CT characterization as a per-lesion set-prediction task: one model emits a variable number of lesions per kidney, each with four clinical attributes. We curated 2,619 CT volumes from 788 patients at one academic medical center, with multi-granularity side- and per-lesion labels, and used KiTS23 (489 cases) for zero-shot external validation. We propose \textbf{LesionDETR}, a DETR-style architecture with size-distance Hungarian matching and a hierarchical loss that aggregates per-slot outputs to side-level objectives. Across four input representations and six encoder initializations, two design choices dominate: a segmentation mask as an input channel, and same-domain abdominal pretraining (SuPreM); generic large-corpus pretraining is no better than random initialization. LesionDETR reaches bilateral side-level abnormality AUC 0.799±0.0090.799 \pm 0.009 on UF-Health and 0.817±0.0720.817 \pm 0.072 on KiTS23. A count-conditioned variant reaches per-lesion mAP 0.190±0.0830.190 \pm 0.083 on cystic lesions; rare solid-lesion AP stays at the noise floor, pointing to targeted data collection, not architecture, as the next bottleneck. The framework yields verified per-lesion predictions for downstream structured report generation.

Explore similar work

May 8, 2026cs.CV

Benchmarking Foundation Models for Renal Lesion Stratification in CT

The rapid proliferation of open-source medical foundation models (FMs) raises a practical question: how well do their pre-trained representations transfer to clinically relevant but data-scarce classification tasks? Particularly in CT-based renal lesion classification, a push toward greater generalizability would be meaningful, as the field is constrained by inherently limited training data. We addressed this through a benchmark of three medical FMs on this specific task. This six-class problem spans common entities like cysts and clear cell renal cell carcinoma, alongside rare subtypes. Using a frozen feature-probing protocol, we compared FM embeddings against a handcrafted radiomics classifier and a 3D ResNet-50 trained from scratch. Models were trained on a composite dataset of 2,854 lesions and evaluated on an external test set of 234 lesions from The Cancer Imaging Archive. Our results reveal two key findings. First, FM performance (AUC 0.70-0.77) matched the from-scratch ResNet (AUC 0.72) while drastically reducing hardware demand, requiring only seconds on a CPU after feature extraction. However, the conventional radiomics baseline significantly outperformed all deep learning approaches, achieving an AUC of 0.88 (all p \leq 0.002). This suggests that current generalist FM embeddings do not yet capture the fine-grained texture and shape heterogeneity driving histological subtype discrimination. Despite their potential in data-scarce settings, medical FMs did not surpass established models for renal lesion stratification, leaving radiomics as the current state-of-the-art.
Hartmut Häntze, Sarah de Boer, Myrthe Buser +7
Jun 29, 2026cs.CV

LETT-NeXt: A Lightweight RECIST-Guided Model for 3D CT Lesion Segmentation

RECIST diameter measurements are widely used for tumor response assessment, but they provide only a limited 2D description of lesion extent. We present LETT-NeXt, a lightweight RECIST-guided model that predicts 3D lesion masks from CT volumes and RECIST markers for the CVPR 2026 Foundation Models for Pan-cancer Segmentation in CT Images competition. LETT-NeXt extracts a RECIST-centered regional crop, encodes the RECIST line and endpoints as two prompt channels, and concatenates them with the CT input. A compact MedNeXt-v2 encoder--decoder predicts the lesion mask, followed by prompt-aware component selection and adaptive AutoZoom inference. On the public validation set, LETT-NeXt achieved a Dice Similarity Coefficient (DSC) of 79.4 ±\pm 10.1 and a Normalized Surface Dice (NSD) of 72.3 ±\pm 16.2. On the hidden test set, it achieved a DSC of 73.9 and an NSD of 67.3, corresponding to a challenge score of 70.6%. On the public validation mirror, LETT-NeXt completed CPU inference in 6.9 ±\pm 3.0 s per case with a peak memory use of 3.6 GB. Code is available at github.com/Ahus-AIM/lett-next.
Sebastian Aas, Elias Stenhede, Arian Ranjbar
May 21, 2026cs.CV

GLeVE: Graph-Guided Lesion Grounding with Proposal Verification in 3D CT

Grounding radiology report descriptions to 3D CT volumes is essential for verifiable clinical interpretation, yet remains challenging due to the semantic-spatial gap between free-text narratives and volumetric anatomy. Existing report-assisted and vision-language grounding methods typically rely on phrase-level alignment or dense pixel supervision, resulting in limited lesion-wise correspondence and suboptimal localization accuracy. We propose GLeVE, a graph-guided lesion grounding framework with anatomical prior verification and octree-based autoregressive refinement. GLeVE treats each lesion description as an atomic semantic unit and encodes organ attribution, attributes, and inter-lesion relations through relation-aware graph reasoning to produce discriminative lesion-wise queries. Anatomy-aware proposal generation with region-level verification enforces one-to-one text-lesion alignment, while hierarchical octree refinement progressively improves boundary delineation. Experiments on AbdomenAtlas 3.0 demonstrate consistent gains over classical multimodal foundation models and report-supervised baselines in both segmentation accuracy and lesion-level localization.
Shuo Jiang, Yuhao Hong, Chunbo Jiang +9