cs.CVJun 3, 2026

LightVesselNet: An Ultra-Lightweight Sub-100K Parameter Network for Retinal Blood Vessel Segmentation

Authors: Shadman SobhanFarhana Jalil

Abstract

Retinal blood vessel segmentation plays a vital role in the early detection of diabetic retinopathy and glaucoma. While recent deep learning models have achieved great segmentation accuracy, they typically require heavy computational resources, making real-world deployment on edge devices difficult. In this paper, we propose LightVesselNet, an efficient neural network designed for retinal vessel segmentation in a resource-constrained environment. Despite containing only 75K parameters, LightVesselNet performs competitively with much larger models. The network employs a compact encoder decoder architecture enhanced with channel and spatial attention mechanisms, a multi-scale feature aggregation module at the bottleneck, and a subpixel upsampling strategy in the decoder. A dedicated edge residual connection preserves fine vessel detail throughout decoding. Extensive experiments on five publicly available datasets: DRIVE, STARE, CHASEDB1, FIVES, and HRF, yield sensitivity scores of 0.8189, 0.8499, 0.8640, 0.8634, 0.8096, and Dice coefficients of 0.8070, 0.8072, 0.8181, 0.8649, and 0.7686, respectively. LightVesselNet shows improved efficiency (Performance vs Parameter or GFlops) compared to State-of-the-Art models. Cross-dataset evaluation confirms the model's generalisation capability. Overall, LightVesselNet is a strong candidate for deployment in low-resource clinical settings and mobile screening tools.

Explore similar work

May 12, 2024eess.IV

Explainable Convolutional Neural Networks for Retinal Fundus Classification and Cutting-Edge Segmentation Models for Retinal Blood Vessels from Fundus Images

Early detection of vision-threatening conditions such as diabetic retinopathy, glaucoma, and age-related macular degeneration depends on retinal fundus image analysis, but manual assessment is slow and expert-dependent. Automated convolutional neural networks classify fundus images accurately yet act as black boxes, and existing retinal vessel segmentation methods lose discriminative power under pathology and seldom exploit attention or transformer backbones. Using the FIVES and DRIVE fundus datasets, we develop a two-pipeline framework that pairs four-class disease classification with attention- and transformer-based vessel segmentation, organised in three stages: (1) FIVES images are augmented by rotation and horizontal and vertical flips and used to fine-tune eight ImageNet-pretrained CNNs: ResNet101, DenseNet169, Xception, InceptionV3, DenseNet121, InceptionResNetV2, ResNet50, and EfficientNetB0. (2) Five gradient-based explanation methods, Grad-CAM, Grad-CAM++, Score-CAM, Faster Score-CAM, and Layer-CAM, are computed on the final convolutional block of each classifier and compared qualitatively across architectures. (3) Ten U-Net variants are benchmarked for vessel segmentation: TransUNet (hybrid CNN--Transformer encoder) and Attention U-Net (gated skip connections), evaluated with ResNet50V2, ResNet101V2, and ResNet152V2 backbones, along with additional Attention U-Net configurations using DenseNet backbones, and the fully transformer-based Swin-UNet. ResNet101 gives the highest classification accuracy: 94.17% (F1 0.942) >> 88.33% for EfficientNetB0. For segmentation, the architecture ranking is consistent on both datasets: Attention U-Net >> TransUNet >> Swin-UNet. The strongest configuration is Attention U-Net with a ResNet101V2 backbone: FIVES IoU 0.722, Dice 0.838; DRIVE IoU 0.648, Dice 0.787, lifting DRIVE IoU 60.80 \rightarrow 64.83 over a prior custom U-Net.
Fatema Tuj Johora Faria, Mukaffi Bin Moin, Pronay Debnath +2
Jul 27, 2026cs.CV

ESRVS: Extreme Semi-Supervised Retinal Vessel Segmentation with a Single Annotated Image

Learning from minimal human supervision is a long-standing goal in medical image analysis, where dense expert annotations are costly. We study retinal vessel segmentation in an extreme semi-supervised setting with one annotated image and a pool of unlabeled images. We propose ESRVS, which selects a representative reference image for manual annotation and transfers vessel cues using target-domain-adapted DINOv3 features. ESRVS constructs a multi granular vessel prototype, combines prototype-similarity maps with a physics-inspired prior to generate initial pseudo-labels, and refines the transferred supervision through weighted pseudo-label training and adversarial refinement. Across eight public datasets, ESRVS achieves the best Dice and clDice on six datasets, and the best HD95 on all eight datasets among the compared semi-supervised methods, although those methods use 10 to 20% labeled data. With Mask2Former, ESRVS retains on average 93.7% of fully supervised Dice and 95.1% of fully supervised clDice. These results demonstrate the potential of foundation-model label propagation for highly label-efficient retinal vessel segmentation. Code is available at https://github.com/IAANNH/ESRVS.
Mingzhi Xu, Yizhe Zhang
May 11, 2026cs.CV

Polygon-mamba: Retinal vessel segmentation using polygon scanning mamba and space-frequency collaborative attention

Retinal vessel segmentation is crucial for diagnosis and assessment of ocular diseases. Notably, segmentation of small retinal vessels has been consistently recognized as a challenging and complex task. To tackle this challenge, we design a hybrid CNN-Mamba fusion network that integrates polygon scanning mamba and space-frequency collaborative attention mechanism for the detection of small vessels. Considering that the traditional mamba architecture with horizontal-vertical scanning may compromise the topological integrity of target structures and result in local discontinuities in small retinal vessels, we present a polygon scanning visual state space model (PS-VSS) to identify small vessel structural features by multi-layer reverse scanning way. Which effectively preserves pixels connectivity, thereby substantially mitigating the loss of information pertaining to small vessels. Furthermore, as we all known that the spatial domain prioritizes positional and structural information, while the frequency domain emphasizes global perception and local detail components, a space-frequency collaborative attention mechanism (SFCAM) is introduced within the skip connection to extract efficient features from the spatial and frequency domains. This strategy empowers the model to dynamically enhance the key features while effectively suppressing clutters. To assess the efficacy of our model, it was tested on three publicly available datasets: DRIVE, STARE, and CHASE_DB1. Compared to manual annotations, our model demonstrated F1 scores of 0.8283, 0.8282, and 0.8251, Area Under Curve (AUC) values of 0.9806, 0.9840, and 0.9866, and Sensitivity (SE) values of of 0.8268, 0.8314, and 0.8484 across three datasets, respectively. The effectiveness of our model was validated through both visual inspection and quantitative analysis.
Yuanyuan Peng, Wen Li