cs.LGJun 3, 2026

Evidence-Guided Neural Architecture Selection under Uncertainty for Subject-Specific Blood Glucose Forecasting

Authors: Md Azharul IslamDwyer DeighanTarunraj SinghaDanial Faghihi

Organizations: Department of Mechanical and Aerospace Engineering, University at Buffalo, Buffalo, NY, USA · Computational and Data-Enabled Sciences, University at Buffalo, Buffalo, NY, USA · University at Buffalo, Buffalo, NY, USA

Abstract

Reliable neural architecture selection is an open challenge in time-series forecasting under limited, noisy, and heterogeneous data, where standard heuristic architecture design and validation approaches fail to ensure accurate and reliable prediction and generalization. We propose EVIDENT (EVidence-based IDEntification of Neural archiTectures), a framework for architecture selection that integrates Bayesian training, evidence-based ranking, and task-specific validation under uncertainty. The framework explores the candidate architecture pool and identifies the lowest-capacity model that satisfies a prescribed validation criterion. We demonstrate this method using temporal convolutional networks (TCNs) for individualized blood glucose forecasting in type 1 diabetes patients. The results show that EVIDENT systematically rejects both under- and over-parameterized TCN architectures on population-level diabetes data, while identifying models that generalize reliably to unseen patients. When multiple architectures are competitive, the framework further supports plausibility-weighted ensemble predictions that enhance predictive performance. Compared with a random-search baseline, EVIDENT identified smaller architectures with more consistent forecasting performance on unseen patients. These findings establish EVIDENT as a strategy to neural architecture discovery, enabling reliable model selection for high-consequence forecasting in data-limited and heterogeneous settings.

Explore similar work

Jun 5, 2026cs.LG

GlucoFM-Bench: Benchmarking Time-Series Foundation Models for Blood Glucose Forecasting

Blood glucose forecasting models are foundational for modern diabetes management systems, as reliable short-term predictions can enable proactive interventions, support automated insulin delivery, and reduce the risk of hypo- and hyperglycemic events. From a modeling perspective, glucose forecasting poses unique challenges due to heterogeneous physiological dynamics across diabetes populations. Traditional machine learning and deep learning models have been extensively evaluated for glucose prediction, yet recent time-series foundation models (TSFMs) remain much less studied in this setting. To bridge this gap, we present GlucoFM-Bench, a comprehensive benchmark evaluating state-of-the-art TSFMs alongside supervised deep learning models for blood glucose forecasting. We assess eight representative architectures, including pre-trained TSFMs, time-series large language models, and task-specific deep learning models, across 15 publicly available diabetes-relevant datasets comprising 1,117 individuals with type 1 diabetes, type 2 diabetes, prediabetes, and no diabetes. Models are evaluated under zero-shot, few-shot, and full-shot protocols, with systematic variation in context length and prediction horizon. Across datasets, pre-trained TSFMs, especially Chronos-2 and TimesFM, show strong zero-shot and few-shot transfer, with the best zero-shot model performing within 5% of the best full-shot supervised model. Yet, when task-specific data are abundant, a lightweight LSTM remains strongest, outperforming TSFMs by 4--21% under full-shot training. Stratified analyses reveal persistent challenges in T1D cohorts and hypo-/hyperglycemic ranges, highlighting the need for evaluation beyond aggregate error metrics. Together, GlucoFM-Bench provides a standardized and reproducible foundation for evaluating, comparing, and improving foundation models for blood glucose forecasting.
Baiying Lu, Zhaohui Liang, Ryan Pontius +2
May 1, 2026cs.LG

From Prediction to Practice: A Task-Aware Evaluation Framework for Blood Glucose Forecasting

Clinical time-series forecasting is increasingly studied for decision support, yet standard aggregate metrics can obscure whether a model is actually useful for the task it is meant to serve. In safety-critical settings, low average error can coexist with dangerous failures in exactly the high-risk regimes that matter most. We present a task-aware evaluation framework for blood glucose forecasting built around two downstream uses: hypoglycemia early warning and insulin dosing decision support. For early warning, we evaluate on real data from three clinical cohorts using event-level recall and false alarms per patient-day, metrics that reflect operational alarm burden rather than aggregate accuracy. We show that models appearing acceptable overall, with recall above 0.9 on the full test set, can fail badly in the post-bolus slice, where insulin-on-board is elevated and missed warnings carry the greatest clinical consequences. Standard forecasting evaluation, however, does not test whether a model can reason about the effects of actions, a requirement for supporting insulin dosing decisions. We therefore add a second, interventional arm using the FDA-accepted UVA/Padova simulator, where we evaluate whether forecasters can predict glucose responses to altered insulin plans in paired factual/counterfactual scenarios. We show that models that look strong on real-data forecasting often fail to predict the direction, magnitude, or ranking of intervention effects, and choose poor insulin doses when evaluated under a clinically motivated cost. Taken together, the two arms reveal a consistent gap between forecasting accuracy and task-relevant usefulness. We release the benchmark, the standardized preprocessing pipeline for public cohorts, and the simulator-based interventional dataset as a reproducible toolkit.
Alireza Namazi, Heman Shakeri
Jun 17, 2026cs.LG

MetaboNet-Bench: A Multi-modal Benchmark for Glucose Forecasting in Type 1 Diabetes

Glucose forecasting algorithms are an important aspect of glycemic control management in type 1 diabetes. So far, the research community has developed numerous algorithms and models for forecasting. However, it is well-recognized that the lack of standardized model performance evaluation benchmarks makes fair comparison difficult and hinders further innovation, and thus benchmark standardization is in urgent need. Furthermore, many published glucose forecasting algorithms are limited to CGM data alone, ignoring other multimodal signals such as insulin dosing and carbohydrate intake. Here, we introduce MetaboNet-Bench, a benchmark for multimodal glucose forecasting for patients with type 1 diabetes that provides an extensible open-source evaluation framework for comparison of glucose forecasting algorithms that leverage glucose, insulin, and carbohydrate data. We then demonstrate its utility by benchmarking several recently published glucose forecasting models and a custom multimodal time-series model, representing different model architectures. The results show that the benefit of adding data modalities is conditioned on the complexity of the model and that incorporating more clinical metrics helps identify meaningful gaps to fill for future research.
Nathaniel Jeffries, Miriam Wolff, Sam Royston +5