cs.LGJun 5, 2026

BCG-FM: A Foundation Model for Ambient Cardiac Health Sensing

Authors: Magnus Ruud KjaerHaejun HanAshish NeupaneDavid Q. Sun

Organizations: AI/ML, Eight Sleep · AI/ML, Eight Sleep (work done while at Eight Sleep)

Abstract

Foundation models for wearable biosignals have matched or exceeded supervised specialists across a range of clinical tasks, yet all rely on modalities that require deliberate user action--wearing a device or visiting a sleep lab. We introduce BCG-FM, the first foundation model for ambient mechanical biosignals. A piezoelectric sensor embedded in the bed surface records ballistocardiography (BCG) each night without user effort; we pretrain BCG-FM with participant-level contrastive learning and using a total of 2.75 million hours of nightly recordings from 145,985 individuals, the largest raw-waveform biosignal pretraining corpus to date. Frozen BCG-FM embeddings achieve 3.26-year MAE on biological-age estimation (the lowest reported for any ambient, contactless modality) and yield clinically relevant discrimination across 15 self-reported health conditions and three independent external cohorts. Pretrained representations from only 500 labeled participants outperform a fully supervised baseline trained on 3,372, and representation quality scales log-linearly with contrastive batch size. These results establish ambient, longitudinal mechanical biosignals as a viable modality for health foundation models.

Explore similar work

May 10, 2026cs.LG

Biosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model

Cardiovascular disease remains the leading cause of global mortality, yet scalable cardiac monitoring is hindered by the gap between diagnostic-rich ECG and ubiquitous wearable PPG. Bridging this gap requires representations that are compact, transferable across modalities and devices, and deployable without task-specific retraining. Here we introduce biosignal fingerprints: compact latent representations of cardiovascular state derived from a cross-modal foundation model, the Multi-modal Masked Autoencoder (M2AE), trained on over 3.4 million paired ECG and PPG signals. M2AE integrates modality-specific encoders with a shared bottleneck and dual decoders, jointly optimized using reconstruction and cross-modal contrastive objectives, yielding generalizable fingerprints that retain intra- and inter-modality features. Like a biometric fingerprint, these representations uniquely encode an individual's cardiovascular state in a modality-agnostic, privacy-preserving form reusable across clinical tasks without exposing raw waveform data or requiring model retraining. Across 7 downstream tasks, spanning cross-modal reconstruction, cardiovascular disease classification, hypertension detection, mortality prediction, and demographic inference, biosignal fingerprints achieve competitive or superior performance compared to leading domain-specialist foundation models in frozen settings, including an AUROC of 0.974 for five-class CVD classification and 0.877 for hypertension detection, with a maximum improvement of 27.7% in AUROC across 5 classification tasks. Critically, strong performance is maintained with only a single modality, enabling deployment in resource-constrained, single-sensor environments typical of real-world wearable monitoring, with direct implications for continuous cardiovascular monitoring across clinical and consumer health settings.
Zhangdaihong Liu, Chang Liu, Fenglin Liu +4
Jun 23, 2026eess.AS

BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions

Respiratory acoustic foundation models (FMs) are benchmarked exclusively on smartphone recordings, yet clinical deployment increasingly targets body-coupled (BC) wearables whose sensors attenuate high-frequency content through tissue and bone, leaving FM reliability uncharacterised. We introduce BCoughBench, evaluating five FMs (OPERA-CT/CE/GT, HeAR, M2D+Resp) on nine classification tasks (AUROC, sensitivity at 95% specificity, Expected Calibration Error) and three age regression tasks (MAE vs. a mean-predictor baseline) across five EBEN-simulated BC sensor conditions on five labeled cough datasets. Mean AUROC declines from 0.785 (smartphone) to 0.689-0.723, degrading most under temple vibration pickup (ΔΔ = -0.096) and least under the soft in-ear (ΔΔ = -0.062). No FM meets the clinical sensitivity threshold (Se@Sp95 \geq 0.20) on most disease tasks under any BC sensor. Sex classification on the CIDRZ cohort collapses (AUROC 0.954 to 0.596-0.628, ΔΔ = -0.341) while COVID detection is nearly unaffected (ΔΔ = -0.004). Age regression is robust, improving under the forehead accelerometer on CoughVID (MAE 9.61 to 8.97 yr); HeAR leads on regression and demographic tasks, M2D+Resp on disease and characteristic tasks. BCoughBench provides a reproducible framework for FM evaluation under wearable conditions.
Mayur Sanap, Prasanna Desikan, Edgar Lobaton
May 4, 2026cs.LG

Pretraining on Sleep Data Improves non-Sleep Biosignal Tasks

Sleep foundation models have recently demonstrated strong performance on in-domain polysomnography tasks, including sleep staging, apnea detection, and disease risk prediction. In this work, we investigate whether sleep biosignals can serve as an effective pretraining distribution for learning representations that transfer beyond sleep to adjacent domains. Following sleep foundation models, we perform sleep-only multimodal contrastive pretraining (with a leave-one-out objective) and evaluate transfer to non-sleep EEG and ECG, two well-benchmarked biosignal modalities with heterogeneous datasets and clinically meaningful downstream tasks. Across eight downstream tasks spanning multiple EEG and ECG datasets, sleep pretraining consistently improves performance relative to training from scratch. Moreover, on several tasks, we achieve performance competitive with or surpassing prior specialized state-of-the-art and foundation models.
William Lehn-Schiøler, Magnus Ruud Kjær, Phillip Hempel +7