Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation. However, even with recent progress, many PPG-based models are trained with BP regression alone and may rely on amplitude-dominated shortcuts. In addition, demographic covariates that systematically modulate vascular compliance are often incorporated only via late fusion, limiting subject-specific representation learning. We propose a Transformer-based network for cuffless BP estimation from PPG signal, leveraging self-attention to capture long-range dependencies across multiple cardiac cycles. To account for subject-specific vascular differences, the model is conditioned on demographics via FiLM-style feature modulation applied through the attention and feed-forward sublayers of Transformer blocks. In addition, we add an auxiliary morphology head to guide the model to attend to BP-relevant waveform morphology associated with arterial stiffness and wave reflection. Under calibration-based evaluation protocols on the large-scale PulseDB dataset, the proposed method achieves MAE of 4.56 mmHg for systolic BP and 2.62 mmHg for diastolic BP, reducing errors by 47% and 50% compared with prior demographic-enhanced PPG baselines. The resulting lightweight, single-sensor model supports scalable and clinically grounded cuffless BP estimation in calibration-enabled deployment settings.
Objective. To develop and evaluate a cuffless continuous blood pressure (BP) estimator using temporal physiological and demographic features. We propose a hybrid Transformer framework to estimate diastolic and systolic BP from ECG/PPG-derived feature sequences. Approach. Rather than raw waveforms, the framework models 10-step sequences of six physiological descriptors and two demographic covariates. A Multi-Source Temporal Encoder Module combines Transformer, Kolmogorov-Arnold Network, and XGBoost branches to capture complementary temporal, nonlinear, and tabular information. A Dynamic Conditional Fusion-Decoder applies differential multi-head attention, token-weighted aggregation, and gated residual correction. A robust composite objective jointly optimizes DBP and SBP. Main results. Using the MIMIC-III Waveform and Clinical Databases, the source pool comprised 28,486 waveform segments from 203 subjects, and feature generation retained 53,621 observations from 166 subjects. On 2,431 segment-level held-out test windows, mean error +/- standard deviation was 0.41 +/- 3.74 mmHg for diastolic BP and -1.60 +/- 5.95 mmHg for systolic BP, with 95% limits of agreement of [-6.93, 7.74] and [-13.25, 10.06] mmHg, respectively. The proportions within 10 mmHg were 98.48% and 94.36%. The framework achieved the lowest standard deviations and narrowest limits of agreement among the locally retrained baselines. Significance. The feature-sequence fusion framework improved agreement with reference BP and fell within numerical AAMI and BHS Grade A thresholds on this split. This retrospective analysis is not formal device validation; subject-disjoint and external evaluation remain necessary before clinical use.
Continuous and cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) is of great interest for low-cost and personalized cardiovascular health management. However, significant population heterogeneity and the "one-to-many mapping" problem, where similar waveforms across individuals correspond to different BP levels, limit the accuracy of conventional population-based models. To address this challenge, we propose a dual-path architecture termed SIFPBPNet, which separately represents steady-state and instantaneous features, through a Steady-state Feature Path (SFP) and an Instantaneous Feature Path (IFP). The SFP employs a Graph Attention Network (GAT) to extract individual-specific and long-term characteristics from multi-day historical PPG trajectories. In parallel, the IFP captures short-term dynamics from current PPG segments and incorporates the steady-state prior via a cross-attention mechanism. Experiments on a large-scale wearable dataset demonstrate that SIFPBPNet achieves a Mean Absolute Error (MAE) of 8.57 and 5.97 mmHg for systolic and diastolic BP, respectively, outperforming state-of-the-art models. Furthermore, the SFP module consistently improves performance when integrated into various backbone architectures, yielding 2.8-13.1% relative MAE reductions for systolic BP. These results highlight the strong generalizability and plug-and-play transferability of the SFP module, underscoring its great potential for accurate cuffless BP monitoring.
This work proposes Attractor-Vascular Coupling Theory (AVCT), a mathematical framework showing that cardiac attractor geometry encodes blood pressure (BP) information sufficient for AAMI-standard estimation, and validates the theory through a calibrated cuffless BP model using photoplethysmography (PPG). AVCT is grounded in Cardiac Stability Theory and operationalized using Takens delay embedding and attractor morphology extraction. Two theorems, one proposition, and one corollary formally justify the use of PPG attractor features for BP estimation and predict the feature-importance hierarchy. A LightGBM model trained on pulse transit time (PTT) and Cardiac Stability Index (CSI) attractor features under single-point calibration was evaluated using strict leave-one-subject-out cross-validation (LOSO-CV) on 46 subjects from BIDMC ICU (n = 9) and VitalDB surgical data (n = 37), comprising 29,684 windows. The model achieved systolic BP (SBP) mean absolute error (MAE) of 2.05 mmHg and diastolic BP (DBP) MAE of 1.67 mmHg, with correlations r = 0.990 and r = 0.991, satisfying the AAMI/IEEE SP10 requirement of MAE below 5 mmHg. Median per-subject MAE was 1.87/1.54 mmHg, and 70%/76% of subjects individually satisfied AAMI criteria. A PPG-only ablation using nine smartphone attractor features matched the ECG+PPG model within 0.05 mmHg, demonstrating that clinical-grade BP tracking is achievable using only a smartphone camera while surpassing prior generalized LOSO-CV results using fewer sensors. All four AVCT predictions were quantitatively confirmed, with 91.5% error reduction from uncalibrated to calibrated estimation (epsilon_cal = 0.915). Unlike post-hoc explainable AI methods, AVCT predicts features satisfying the architectural faithfulness criterion of the Explainable-AI Trustworthiness (EAT) framework and grounding BP estimation in nonlinear dynamical systems theory.