CEVAR: Centerline Embedding Extraction for Endovascular Aneurysm Repair
Authors: Roman Naeem, Timo Niiniskorpi, Charlotte Sandström, Naman Desai, Anders Jeppsson, Ida Häggström, Fredrik Kahl, Håkan Roos, +1 more
Organizations: Chalmers University of Technology, 412 96 Gothenburg, Sweden · The University of Gothenburg, 405 30 Gothenburg, Sweden · Sahlgrenska University Hospital, 413 45 Gothenburg, Sweden
Long-term mortality rates after endovascular aneurysm repair (EVAR) remain elevated due to post-EVAR rupture caused by loss of seal in stent graft sealing zones. Structured CT review using centerline measurements improves detection, but current workflows require manual centerline editing and expert operators. We propose a transformer framework for automated, protocol-driven sealing zone assessment that combines 3D centerline tracking with embedding-based geometric prediction. Two state-of-the-art image-to-graph models are evaluated for aorto-iliac centerline extraction from follow-up CT and for measurement of stent position, vessel diameters, and seal lengths according to EVAR4C protocol. Across the full test set and a challenging no-contrast subset, the proposed fully automatic method outperforms the commercial semi-automatic workflow.
Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates. Convolutional neural networks (CNNs) rely on local pixel intensities, causing systematic confusion between saccular aneurysms and vascular bifurcations - a problem especially acute for small lesions (<3 mm), where detection sensitivity falls below 60%. We propose a plug-and-play, topology-aware false-positive reduction framework evaluating the Smooth Euler Characteristic Transform (SECT) - a directional representation encoding global 3D vascular geometry independently of intensity - against persistence-based summaries (Persistence Images and Landscapes), tested on a stratified subset of the RSNA 2025 dataset. SECT achieves an AUC of 0.943, substantially outperforming direction-agnostic methods (AUC ~0.68), and exhibits a clinical performance inversion: it excels on the sub-3 mm cohort, maintaining 0.943 AUC and 78.5% sensitivity at 95% specificity. The representation is also scanner-agnostic, achieving 0.927 mean AUC under leave-one-scanner-out (LOGO) validation across four manufacturers. By capturing asymmetric geometric invariants rather than intensity profiles, SECT reliably resolves the primary structural confounder in IA detection, positioning it as a robust downstream filter for hybrid deep-learning diagnostic pipelines.
Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.
Alessandra Zerillo, Stefano Cannata, Diego Bellavia +4
Fenestrated/Branched endovascular aneurysm repair (FEVAR/BEVAR) require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta, before deploying stent grafts to alleviate pressure on the aneurysm. Previous clinical studies suggests that surgeons continue to struggle with vessel access using standard commercial instruments, prolonging the procedural time and inducing further complications. In this work, we present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity. 2) An expandable, modular tendon-driven actuation platform that can accommodate for the redundancies introduced in our system. To fabricate the catheter, we capitalized on thermal fiber drawing, a technique that creates high-aspect ratio devices at scale, and processed the catheter with laser micro-machining to soften its tip. We evaluated the system using simulations, where we investigated the catheter's bending stiffness, then its steerability with in-vitro experiments in vascular phantoms. This handheld, robotic steerable catheter system has the potential to shorten the length of future endovascular surgeries, and give clinicians the tools to resolve challenging clinical cases.