cs.CVJun 16, 2026

Neural Phase Correlation

Authors: Cole Reynolds

Organizations: Weyl Labs

Abstract

Correspondence is fundamentally relational: it seeks the unknown transformation between two observations of a common scene, not the content of either. Yet the dominant learning-based methods do not represent the transformation as a first-class object in the architecture. They encode each image independently and let a learned similarity function or a deep decoder discover the mapping implicitly. Phase correlation is the canonical exception, measuring the inter-image relationship directly in the Fourier domain, but the rigidity of its fixed basis confines it to global translation. We introduce a learned generalization of phase correlation that lifts this restriction by learning the basis on which the transformation decomposes. The same algebraic primitive extends to dense non-rigid deformations and to unitary dynamics. On the ACDC cardiac-MRI benchmark the framework matches or exceeds prior published baselines on both registration directions. On CAMUS echocardiography it matches state-of-the-art without auxiliary scoring or adaptive-smoothness mechanisms. Applied to time-evolved wavefunction pairs of the 1-D quantum harmonic oscillator, the same framework recovers the Hermite-function eigenstates and the quantized energy levels of the unknown Hamiltonian from observation pairs alone.

Explore similar work

May 11, 2026eess.IV

Set-Based Groupwise Registration for Variable-Length, Variable-Contrast Cardiac MRI

Quantitative cardiac magnetic resonance imaging (MRI) enables non-invasive myocardial tissue characterization but relies on robust motion correction within these variable-length, variable-contrast image sequences. Groupwise registration, which simultaneously aligns all images, has shown greater robustness than pairwise registration for motion correction. However, current deep-learning-based groupwise registration methods cannot generalize across MRI sequences: the architecture typically encodes input data as a fixed-length channel stack, which rigidly couples network design to protocol-specific sequence length, input ordering, and contrast dynamics. At inference time, any change in imaging protocols will render the network unusable. In this work, we introduce \emph{\AnyTwoReg}, a new set-based groupwise registration framework that takes a quantitative MRI sequence as an unordered set. This set formulation fundamentally decouples network design from sequence length and input ordering. By utilizing a shared encoder and correlation-guided feature aggregation, \emph{\AnyTwoReg} constructs a permutation-invariant canonical reference for registration, and learns a permutation-equivariant mapping from images to deformation fields. Additionally, we extract contrast-insensitive image features from an existing foundation model to handle extreme contrast variations. Trained exclusively on a single public T1T_1 mapping dataset (STONE, sequence length L=11L=11), \AnyTwoReg generalizes to two unseen quantitative MRI datasets (MOLLI, ASL) with variable lengths (L[11,60]L \in [11, 60]) and different contrast dynamics. It achieves strong cross-protocol generalization in a zero-shot manner, and consistently improves downstream quantitative mapping quality. Notably, while designed for quantitative MRI sequences, our framework is directly applicable to Cine MRI sequences for inter-cardiac-phase registration.
Yi Zhang, Yidong Zhao, Tijmen Toxopeus +3
Sep 11, 2026cs.CV

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.
Mohammadjavad Matinkia, Nilanjan Ray
Aug 12, 2026eess.IV

Alignment of Similarity-Transformed Images Based on Fourier--Mellin Transform Using Auxiliary Function Method

This paper proposes an algorithm for estimating the similarity transformation, namely translation, scale, and rotation, between two images with subpixel accuracy. Image registration is a fundamental technique for aligning images acquired under different viewpoints and imaging conditions, and a representative approach based on maximizing discrete cross-correlation is the Fourier--Mellin registration. However, the Fourier--Mellin approach often fails to achieve sufficient alignment accuracy when subpixel-level estimation is required. The proposed method integrates (i) scale-and-rotation estimation from the Fourier magnitude spectrum in a log-polar representation and (ii) maximization of phase-only correlation based on the auxiliary function method. This integration enables a two-stage estimation procedure: it first estimates scale and rotation without being affected by translation, and then estimates translation with subpixel precision in the spatial domain using the corrected image pair. A simulation experiment on image pairs subjected to random similarity transformations demonstrates that the proposed method reduces estimation errors in scale, rotation, and translation compared with Fourier--Mellin-based registration methods using discrete cross-correlation.
Shinji Yamashita, Yuma Kinoshita, Hitoshi Kiya