eess.IVJun 19, 2026

Configurable Algorithms for Histopathologic Cancer Detection on Quantum Hardware

Authors: Nandika GoyalGlen UeharaAndreas Spanias

Organizations: SenSIP Center, School of ECEE · Arizona State University

Abstract

Histopathologic cancer detection is challenging due to tissue variability, staining differences, and subtle visual distinctions between disease classes. We propose two quantum algorithms for this task: a configurable dual-gradient CSWAP circuit (DG-CSWAP) that computes multi-directional edge responses in a single execution via per-pixel local Ry encoding, and a hardware-efficient destructive swap circuit (DG-DST) natively matched to quantum processing unit (QPU) gate sets at substantially lower circuit complexity. We prove algebraic equivalence between DG-CSWAP and DG-DST, enabling a two-circuit QPU validation strategy. A three-stage NISQ mitigation pipeline, including readout error correction, bias subtraction, and slope regression, reduces single-pixel hardware MSE by ~8x. Validated on five quantum processors via Amazon Braket, the method achieves inter-platform Pearson r ~ 0.93-0.94 across all local-simulator pairs. Compared to a prior Quantum Fourier Transform (QFT) based amplitude-encoding baseline requiring 12-qubit global state preparation and a three-model ensemble (85.55% on PatchCamelyon), the proposed method uses shot-based measurements, executes on real quantum hardware, and achieves 79.80% accuracy with a single ResNet-50. A Lite configuration delivers a 17x preprocessing speedup at a 2.59% accuracy cost. To the best of our knowledge, this is the first quantum hardware implementation study with noise mitigation for histopathologic image classification.

Explore similar work

May 1, 2026cs.CV

Quantum Gradient-Based Approach for Edge and Corner Detection Using Sobel Kernels

Edge detection refers to identifying points in a digital image where intensity changes sharply, indicating object boundaries or structural features. Corners are locations where gray-level intensity changes abruptly in multiple directions and are widely used in feature extraction, object tracking, and 3D modeling. In this study, we present a quantum implementation of Sobel-based edge detection and Harris-style corner detection. Two quantum image encoding methods - Flexible Representation of Quantum Images (FRQI) and Quantum Probability Image Encoding (QPIE) - are used to encode the input data and are comparatively analyzed. The proposed approach introduces a quantum gradient computation scheme based on lag-2 differences, enabling the evaluation of gradient-like features in superposition. To improve detection quality and reduce false positives, a classical post-processing step is applied to candidate corner points identified by the quantum circuit. Results show that the proposed quantum circuits produce outputs consistent with classical Sobel and Harris operators. Furthermore, the QPIE-based configuration yields more stable and coherent results than FRQI, especially under limited measurement shots. While gradient computation can be performed efficiently at the circuit level, the overall cost remains dominated by state preparation, measurement, and classical post-processing. All experiments are conducted under noiseless simulation, and performance on NISQ hardware may be affected by noise and measurement limitations. Therefore, this work demonstrates a functional and scalable quantum realization of classical edge and corner detection methods rather than an end-to-end speedup.
Mohammad Aamir Sohail, Gabriela Pinheiro, Yasemin Poyraz Kocak +4
Jun 26, 2026quant-ph

Parameter-Efficient Continuous-Variable Photonic Quantum Neural Networks for Edge Quantum AI: Demonstration in Oral Cancer Detection

Early detection of oral cancer markedly improves clinical outcomes, yet specialized diagnostic tools remain scarce in low-resource settings. Smartphone-based screening is a scalable alternative but needs lightweight models that run within edge-hardware constraints. Hybrid classical-quantum architectures are emerging candidates for parameter-efficient learning, yet most rely on qubit hardware that needs cryogenic operation, unsuitable for edge deployment. Continuous-variable (CV) photonic quantum computing, which operates at room temperature, offers a complementary route. We investigate a hybrid classical-CV quantum classifier for oral cancer detection from smartphone images. The pipeline combines a MobileNetV1 feature extractor, principal component analysis to 16 dimensions, and a parameterized CV-QNN of displacement, interferometric, and Kerr gates on a photonic backend. We propose a simplified ΦDU1Φ\circ D \circ U_1 CV-QNN architecture that cuts trainable parameters 40-45% relative to the standard CV-QNN layer of Killoran et al. (2019a), and identify dimensionality-reduction and encoding-restriction strategies that mitigate barren plateaus, raising loss-gradient variance by roughly 58 orders of magnitude. Whether the simplified layer beats the full layer is width-dependent: the full layer holds a small but significant edge at two qumodes, whereas the simplified layer is significantly better at four qumodes using 44% fewer parameters. The strongest model, a four-qumode simplified CV-QNN with only 18 parameters, attains the highest validation AUC of all models, exceeds a 55-parameter classical baseline using 67% fewer parameters, and reaches 100% calibrated test accuracy across all seeds. These results support CV photonic quantum machine learning for parameter-efficient, room-temperature medical image classification and motivate progress toward edge quantum AI.
Akshay Bhagwan Sonawane, Sophie Choe, Lakshman Tamil
Jul 9, 2026cs.CV

ProsMAE: Multi-Source MAE Pretraining for ISUP Grade Classification

Whole slide images (WSIs) provide rich diagnostic information for computational pathology, but their gigapixel scale, stain variation, scanner differences, tissue artifacts, and limited expert annotation make robust model training challenging. This paper presents a multi-source Masked Autoencoder (MAE) framework, named ProsMAE, for histopathology representation learning. Tiles from Prostate cANcer graDe Assessment (PANDA), CAncer MEtastases in LYmph nOdes challeNge 2017 (CAMELYON17), and BReAst Carcinoma Subtyping (BRACS) are used for ProsMAE pretraining to expose the encoder to diverse tissue morphology and acquisition conditions. The learned encoder is transferred for International Society of Urological Pathology (ISUP) grade classification through ProsCLS, using a frozen encoder and a linear classification head. ProsMAE achieved a higher mean validation quadratic weighted kappa (QWK) than the vanilla MAE frozen linear-probe baseline under the evaluated disjoint PANDA split. Repeated-split evaluation remains necessary to further establish robustness across split compositions.
Anna Jung, Kyeonghun Kim, Youngung Han +6