cs.CVJun 21, 2026

FetSelect: Task-Specific Architectures and Self-Supervised Learning for Automated Fetal Ultrasound Frame Selection

Authors: Mahmood AlzubaidiRaden MuazUzair ShahMohammed AmmarKhalid AlyafeiMowafa HousehMarco Agus

Organizations: College of Science and Engineering, Hamad Bin Khalifa University, Doha, Qatar · LIST Laboratory Department of Electrical Systems Engineering, University of Boumerdes, Boumerdes, Algeria · Sidra Medicine, Doha, Qatar

Abstract

Automated frame selection for fetal biometry remains under addressed, with most prior work targeting generic quality assessment or downstream measurement pipelines that assume suitable frames are available. We introduce FetSelect, a task-specific framework that pairs a frozen vision foundation backbone with a hybrid multi-head design: a Task-Gated classification head and a Detection-derived quality head combined via learned fusion. We curate 6,486 expert-labeled frames across four targets: Crown-Rump Length (CRL), Nuchal Translucency (NT), Nasal Bone (NB), and Scalebar, and adapt the backbone with BYOL pretraining on 19,019 unlabeled images. On a held-out test set (974 frames), FetSelect achieves mean AUROC 0.956 and mean correlation 0.818 with expert quality annotations. Ablations confirm that hybrid fusion surpasses single-head variants, and ultrasound-specific self-supervision yields consistent gains. Evaluation on external clinical videos and 509 external CRL images demonstrates task-specific discrimination.

Explore similar work

Aug 5, 2026cs.CV

FUSEP: A Multi-Center Benchmark for Diverse Tasks in Early Pregnancy Fetal Ultrasound Screening

A large number of infants with congenital anomalies are born each year globally, especially in areas with underdeveloped medical resources. Currently, fetal ultrasound screening is the most common modality for early pregnancy anatomy detection. This modality can detect anomalies earlier and provide opportune treatment advice. However, the lack of an ultrasound dataset on early fetal gestation has slowed down the development of automated assisted diagnosis. In this work, we present a benchmark dataset for Fetal Ultrasound Screening in Early Pregnancy to facilitate intelligent ultrasound examination and assisted diagnosis called FUSEP. Our dataset consists of two ultrasound views recommended by the international guideline, i.e., Crown-rump Length (CRL) and Nuchal Translucency (NT) views in three hospitals, totaling 4,017 ultrasound images, with 45,820 box-level expert-level annotations. Our dataset and baseline present the following three contributions: 1) Our medical experts annotated a total of 14 key anatomical structures in two views using a box-level format; 2) Our data is collected extensively from different sonographers, devices, scanning angles, hospitals, etc; 3) We report the performance of the semi-supervised learning, fully supervised learning, unsupervised domain adaptation (UDA), and source-free UDA in ultrasound images multi-object detection. To the best of our knowledge, this is the first publicly available dataset and benchmark for fetal early pregnancy ultrasound screening. We believe that FUSEP and benchmark can contribute to the medical community in the development of multiple tasks such as standard plane recognition, quality control on ultrasound images, automated assisted diagnostics in early fetal pregnancy, medical multi-object detection, domain adaptation for object detection, etc.
Bin Pu, Jiewen Yang, Liwen Wang +9
Jul 1, 2026cs.CV

Foundation Model-driven Key Anatomy Frame Selection for Blind-sweep Ultrasound Fetal Birth Weight Estimation

Accurate fetal birth weight (FBW) estimation shortly before delivery is clinically valuable yet challenging due to its reliance on operator expertise, particularly in low-resource settings. To reduce this reliance, we study near-term birth-weight regression from blind-sweep ultrasound (US) videos acquired within 48 hours prior to delivery, with post-delivery weighing as ground truth. Accordingly, we propose a foundation model-driven key anatomy frame selection framework that enables accurate FBW regression despite the absence of plane constraints in blind sweeps. Our highlights are as follows: (1) We believe this is the first work to estimate FBW using blind-sweep US videos, enabling operator-independent assessment. (2) An Anatomy-Guided Frame Selection module equipped with a vision-language foundation model is proposed for keyframe collection in unconstrained sweeps. (3) A Redundancy-Aware Feature Compression module is designed to compress frame features while preserving task-relevant information, alleviating temporal redundancy. Extensively validated on prospectively collected data from 839 patients, our method achieves an MAE of 161.3 g, with 90.23% and 100% of cases falling within 10% and 15% absolute percentage error, outperforming typical Hadlock estimation and strong competitors. Codes are available at https://github.com/ouleoule/BlindSweep-EBW.
Le Ou, Xiliang Zhu, Huanwen Liang +8
May 27, 2026eess.IV

Benchmarking Ultrasound Foundation Models for Fetal Plane Classification

Ultrasound is widely used in obstetric care due to its safety, accessibility, and real-time imaging. However, interpretation remains operator-dependent and susceptible to noise and artifacts. Deep learning models have shown strong performance to solve these problem, but they typically require large annotated datasets that are difficult to obtain in clinical ultrasound. Foundation models (FMs) offer an alternative, using a large number of ultrasound images to learn transferable representations that can generalize with limited labeled data. This work presents a comprehensive benchmark of ultrasound-specific FMs for fetal plane classification. We evaluated four ultrasound FMs (USFM, MOFO, UltraSAM, FetalCLIP) against two CNN baselines (ResNet50, EfficientNet-V2) and a ViT (DINOv3) pretrained on natural images. We trained all models under two complementary settings: full fine-tuning and linear probing with a frozen encoder. All models were trained using 5-fold patient-level cross-validation on a Spanish fetal ultrasound dataset and tested on both in-domain data and an external African cohort to assess cross-population generalization. We found that FetalCLIP achieved the best results in the linear probing setting (F1 = 0.9261 for in-domain, F1 = 0.9731 for out-of-domain), while USFM performed best in the full fine-tuning setting (F1 = 0.9476 for in-domain, F1 = 0.9515 for out-of-domain). MOFO and UltraSAM degraded most in both settings, underperforming natural image pretrained models in some cases. These findings highlight how the choice of pretrained model strongly affects fetal plane classification performance, since different pretraining objectives lead to different levels of transferability.
Leya Barrientos, Yuexi Du, Nicha C. Dvornek