Organizations: School of Computer Science and Information Technology, Adelaide University, SA 5005, Australia · Australian Institute for Machine Learning (AIML), Adelaide, Australia · Pi MedTech, Adelaide, Australia · School of Electrical and Electronic Engineering, Adelaide University, SA 5005, Australia
Multimodal large language models (LLMs) are increasingly adopted to interpret 12-lead ECG images, though the interpretations often lack validation. However, ECG image understanding significantly differs from general images as it depends on precise waveform morphology, lead relationships and accurate interval measurements. This study investigated whether zero-shot multimodal LLMs can reliably distinguish normal and abnormal ECG images and, in parallel, evaluated CNN-based models for clinically grounded references. Standard 12-lead ECG recordings were rendered as single-page images for a binary normal-abnormal classification task. Three prominent LLMs (GPT-5.2, GPT-4.1, and Gemini-2.5 Pro) were tested using a fixed zero-shot prompt across multiple runs. In parallel, a physiology-aware CNN-based model was developed with the capability to aggregate features from the predefined anatomical lead groups. The model was compared with ResNet18, DenseNet121, VGG16 baselines, and all the models were evaluated on an internal test set and external PTB-XL dataset. Across seeds, CNN-based models demonstrated stable discrimination, with average internal ROC-AUC of 0.92-0.94, and external ROC-AUC of 0.85-0.86. The proposed LeadGroupECG model significantly improved over its backbone internally without compromising external generalization. It remained competitive with other baselines, while consistently highlighting anatomical lead-group contributions. In contrast, zero-shot LLM discrimination remained near-chance (ROC-AUC around 0.5). The PR-AUC improved slightly when ECGs used a grid-based calibration background compared with the grid-free ECGs. Although multimodal LLMs can generate reasonable ECG narratives, their zero-shot diagnostic discrimination remains limited. Therefore, clinically framed, domain-specific architectures remain essential for AI-based ECG interpretation.
The electrocardiogram (ECG) is a cornerstone of cardiac as- sessment, yet clinical deployment of deep learning models remains con- strained by limited interpretability and the hallucination risk of large language models (LLMs). Existing CNN+Grad-CAM+multimodal LLM frameworks can generate ECG reports, but their explanations are often only weakly grounded in established diagnostic criteria, reducing trust- worthiness and reproducibility. We propose a guide-grounded multimodal framework that explicitly anchors report generation in curated clinical knowledge. A convolutional neural network (CNN) and Grad-CAM first produce class probabilities and class-specific heatmaps from 12-lead ECG images. In parallel, authoritative ECG textbooks and guideline materials are distilled offline into a structured ECG Interpretation Guide, which is injected as a fixed knowledge block for every sample. Conditioned on the ECG image, Grad-CAM overlay, CNN-derived fact pack, and the in- jected guide, a multimodal LLM generates structured diagnostic reports with guideline-consistent terminology and criteria usage. Experiments on the full PTB-XL test set demonstrate that guide grounding improves se- mantic quality and perceived consistency of generated reports while pre- serving competitive classification performance. In particular, our method increases the average BERTScore of generated impressions from 0.818 to 0.953 relative to a strong CNN+Grad-CAM+MLLM baseline, indicat- ing closer alignment with reference reports. These findings suggest that injecting a distilled interpretation guide into the multimodal prompting pipeline offers a practical pathway to reduce hallucinations and enhance the clinical plausibility of LLM-based ECG explanations, bringing ex- plainable cardiac diagnosis closer to real-world deployment.
ECG-Language Models (ELMs) extend recent advances in Multimodal Large Language Models (MLLMs) to automated ECG interpretation. However, most existing ELMs inherit Vision-Language Model (VLM) design choices and rely on pretrained ECG encoders, introducing substantial architectural and training complexity. Inspired by encoder-free VLMs, we introduce ELF, a family of three encoder-free ELMs that remain competitive with, and often outperform, prior state-of-the-art ELMs across two datasets despite substantially simpler architectures and training pipelines. All code and data are available at github.com/ELM-Research/ECG-Language-Models.
The accurate automated diagnosis of cardiac abnormalities from 12-lead electrocardiograms (ECGs) is critical for managing cardiovascular disease. However, detecting concurrent conditions remains a challenge for traditional deep learning models, which often have limited ability to model the long-range dependencies inherent in ECG signals. This manuscript proposes HexagonalWarriorMamba (HWMamba), a framework built on the Mamba architecture that processes 12-lead ECGs as single-channel 2D images rather than conventional 1D time series. By integrating a hierarchical architecture with a 2D Selective Scan mechanism, HWMamba is designed to model global context and complex spatial relationships within the data. The model is evaluated on the PhysioNet/Computing in Cardiology Challenge 2021 dataset, which includes 26 diagnostic labels and comprises recordings collected from seven institutions across four countries and three continents. Results demonstrate that HWMamba outperforms current state-of-the-art (SOTA) methods across five key threshold-dependent metrics, including Challenge Score and Subset Accuracy. These improvements provide a balance between strong discriminative capability and effective threshold selection derived from the training data, while maintaining near-SOTA performance in Macro AUROC. This Hexagonal Warrior performance, reflecting consistent performance across multiple evaluation dimensions, positions HWMamba as a robust and versatile approach for multi-label ECG classification.