Existing medical AI benchmarks lack process visibility, atomic skill evaluation, and integrated hallucination detection. We introduce MedBench v5, a redesigned benchmark for clinical multimodal models (language, vision-language, and agent systems) that moves from static QA to dynamic, process-oriented evaluation. MedBench v5 features: (1) a dual-dimensional framework combining Clinical Cognitive Responsiveness (13 sub-dimensions) and Medical Atomic Skills (4 agent environments), covering 63 tasks; (2) three switchable information-flow stressors (omission, contradiction, evidence delay) for factorized degradation analysis; (3) a dynamic process audit protocol with five reasoning nodes that produces model-specific failure fingerprints; (4) hallucination propagation monitoring across initiation, propagation, anchoring, and contradiction interaction-capturing silent hallucination. Experiments on frontier models show that strong overall task performance does not guarantee process stability: stressors mainly disrupt contradiction detection, diagnosis updating, hallucination propagation, and contradiction-based self-correction, while final evidence grounding can remain superficially stable. MedBench v5 provides a unified infrastructure for capability profiling, controllable stress testing, process auditing, and hallucination trajectory analysis in clinical AI evaluation.
Recent advances in large language models and vision-language models have enabled reasoning over multimodal data, offering opportunities for clinical applications such as decision support and triaging. However, existing medical AI benchmarks are fragmented: some support multi-turn dialogues but lack images, while others provide multimodal inputs but focus on single-turn QA tasks. To address this gap, we introduce IMCBench, an image-grounded, multi-turn medical conversation benchmark that pairs real, publicly available clinical images with synthetic patient profiles to simulate realistic patient-clinician interactions. Each conversation is evaluated across three clinical dimensions: safety, accuracy, and appropriate use of uncertainty in diagnosis. We benchmark eight multimodal frontier models across four model families (Claude, GPT, Nova, and Llama), scoring each on a 1-5 scale using LLM-as-Jury scoring calibrated against expert clinician annotations. Our results show that Claude Opus 4.6 achieves the highest overall score (3.61), followed by Claude Sonnet 4.6 (3.30) and GPT-5.2 (3.29), though no model dominates all dimensions and safety degrades for both malignant and rare conditions (Δ = -0.27 each). Ablation studies further reveal that both visual input and EHR context contribute to safe guidance (safety drops of 0.18 and 0.23 on average when each is removed), with stronger models leveraging visual features more effectively. Together, these findings demonstrate that accurate clinical description does not guarantee safe patient guidance, motivating the need for multi-dimensional evaluation frameworks in medical AI.
Maria Xenochristou, Ashutosh Joshi, Korosh Vatanparvar +10
Building trustworthy medical multimodal large language models (MLLMs) is critical for reliable clinical decision support. Existing medical hallucination benchmarks mainly focus on data collection, but often ignore where hallucinations originate within the reasoning process. We find that hallucination sources vary across samples: errors may arise from visual misrecognition, incorrect medical knowledge recall, or flawed reasoning integration. To enable source-level hallucination diagnosis, we introduce ClinHallu, a benchmark for stage-wise hallucination diagnosis in medical MLLM reasoning. ClinHallu contains 7,031 validated instances, where each instance is augmented with a structured reasoning trace decomposed into Visual Recognition, Knowledge Recall, and Reasoning Integration. We also use stage-replacement interventions to measure how correcting specific stages affects the final answer. Beyond evaluation, we show that trace-supervised fine-tuning reduces stage-wise hallucinations. ClinHallu provides a fine-grained hallucination testbed for diagnosing and mitigating reasoning failures in medical MLLMs. The benchmark is publicly available at https://github.com/alibaba-damo-academy/ClinHallu.
Most medical AI benchmarks measure whether a model knows the correct answer. MedFailBench asks a different question: which safety boundary failed? We present a clinician-built synthetic benchmark and failure atlas that labels medical AI errors by severity (1--5) and safety gate type (missed urgent escalation, unsafe remote dosing, unsafe discharge reassurance, evidence fabrication, unsafe protocol execution, source support gap). The current public release (v0.2.1) contains 44 clinician-reviewed synthetic cases with severity annotations, a live HuggingFace leaderboard preview, a safety gate taxonomy, a clinical severity rubric, and an automated pipeline for archiving model-response screening runs. No patient data, clinical validation claims, or model rankings are included. MedFailBench is released under Apache-2.0 and CC-BY-4.0 and carries the Zenodo DOI 10.5281/zenodo.21205535.