cs.AIJun 25, 2026

A Latent ODE Approach to Spatiotemporal Modeling of Cine Cardiac MRI

Authors: David BrüggemannEkaterina KrymovaFirat ÖzdemirJochen von SpiczakSebastian KozerkeSamia MoraRobert MankaMathieu Salzmann+1 more

Organizations: Swiss Data Science Center, EPFL and ETH Zürich, Switzerland · Diagnostic and Interventional Radiology, University Hospital Zürich, Switzerland · Institute for Biomedical Engineering, University and ETH Zürich, Switzerland · Biomedical Informatics Group, ETH Zürich, Switzerland · Division of Preventive Medicine, Brigham and Women’s Hospital / Harvard Medical School, USA

Abstract

Cardiac magnetic resonance imaging (CMR) captures rich spatiotemporal information about ventricular structure and motion, but conventional risk models use only a few image-derived indices from selected cardiac phases. We present a latent dynamical model that encodes bi-ventricular anatomy and full-cycle cine motion as a continuous latent trajectory, using heart-rate-aware neural ordinary differential equation (ODE) dynamics and a graph-based mesh autoencoder to reconstruct anatomically consistent 3D+t ventricular motion. A covariate-conditioned prior defines the expected end-diastolic latent state, and a Cox proportional hazards model tests whether deviations from this prior predict incident heart failure. We studied 72,386 UK Biobank participants without baseline cardiovascular disease, including 367 incident heart failure events. In a held-out evaluation subset, adding the latent score to refitted pooled cohort equations improved the stratified C-index from 0.704 to 0.785, compared with 0.764 for seven established cardiac markers. Compared with non-graph and non-ODE approaches, the proposed model gave the best trade-off between reconstruction fidelity, generative realism, and downstream prognostic performance. These results suggest that continuous full-cycle modeling of ventricular motion provides informative cardiac phenotypes beyond conventional CMR summaries, while external validation in more representative patient cohorts is required before clinical risk-prediction use.

Explore similar work

Jan 28, 2026eess.IV

ECGFlowCMR: Pretraining with ECG-Generated Cine CMR Helps Cardiac Disease Classification and Phenotype Prediction

Cardiac Magnetic Resonance (CMR) imaging provides a comprehensive assessment of cardiac structure and function but remains constrained by high acquisition costs and reliance on expert annotations, limiting the availability of large-scale labeled datasets. In contrast, electrocardiograms (ECGs) are inexpensive, widely accessible, and offer a promising modality for conditioning the generative synthesis of cine CMR. To this end, we propose ECGFlowCMR, a novel ECG-to-CMR generative framework that integrates a Phase-Aware Masked Autoencoder (PA-MAE) and an Anatomy-Motion Disentangled Flow (AMDF) to address two fundamental challenges: (1) the cross-modal temporal mismatch between multi-beat ECG recordings and single-cycle CMR sequences, and (2) the anatomical observability gap due to the limited structural information inherent in ECGs. Extensive experiments on the UK Biobank and a proprietary clinical dataset demonstrate that ECGFlowCMR can generate realistic cine CMR sequences from ECG inputs, enabling scalable pretraining and improving performance on downstream cardiac disease classification and phenotype prediction tasks.
Xiaocheng Fang, Zhengyao Ding, Guangkun Nie +9
Aug 3, 2026cs.CV

Generative Brownian Bridge Diffusion In Motion Space For Enhanced Myocardial Strain Analysis

Myocardial strain analysis of cardiac magnetic resonance (CMR) images provides an important tool for evaluating cardiac function. However, current techniques require either human-adjusted post-processing with suboptimal regional accuracy, or specialized acquisitions with limited availability. In this paper, we propose to leverage the power of generative models to synthesize high-quality motion-derived strain values from routinely acquired CMR sequences. Specifically, we develop a novel Brownian bridge diffusion model in motion space to learn the probabilistic mapping between standard CMR motion estimated from widely adopted registration methods and highly accurate motion provided by advanced strain imaging techniques. To promote the fidelity of anatomical structure in the generation process, our model is conditioned on the corresponding CMR images. We validate our method on large-scale multi-center CMR datasets including subjects of paired standard cine CMR and advanced strain imaging acquisitions. Experimental results demonstrate that our framework significantly improves the accuracy of motion prediction and strain analysis from standard CMRs compared to existing learning-based approaches. Our research represents a new paradigm for potentially developing cost-effective, clinically deployable AI tools for cardiac function assessment with enhanced strain accuracy in busy clinical workflows. Our code is publicly available at https://github.com/Rishov-MIA/Brownian-Bridge-strain-analysis.
Rishov Paul, Frederick H. Epstein, Miaomiao Zhang
Aug 31, 2026cs.CV

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.
Athira J. Jacob, Puneet Sharma, Dorin Comaniciu +1