Organizations: Kingston University, Kingston upon Thames KT1 2EE, UK Quantum AI (QAI) Research Group School of Computer Science and Mathematics (CSM) Faculty of Engineering, Computing and the Environment (ECE)
Abstract
We study a quantum autoencoder (QAE) for compression-driven anomaly detection in brain MRI data. The approach leverages angle encoding to map image patches into quantum states, followed by a variational encoder-decoder architecture trained to discard information via auxiliary trash qubits. Anomaly scores reflect the degree to which inputs resist compression relative to normal data, with higher scores corresponding to deviations from the learned normal manifold. Evaluated on publicly available brain MRI DICOM datasets, the method achieves a slice-level ROC-AUC of approximately 0.95 and a patch-level ROC-AUC of approximately 0.813, outperforming classical autoencoder and PCA baselines. Analysis of the learned parameters reveals a pronounced encoder-decoder asymmetry, where effective anomaly detection arises from structured information compression within the encoder rather than increased parameter magnitude or decoder expressivity. This results in a controlled compression-reconstruction trade-off with a clear operating regime that supports principled threshold selection. Qualitative evaluation further shows that the QAE produces spatially localized anomaly heatmaps aligned with tumorous regions. The results, supported by promising baseline performances, demonstrate that quantum autoencoders provide an interpretable and controllable mechanism for anomaly detection based on incompressibility with respect to a learned latent representation. This work highlights the potential of quantum autoencoders as a principled tool for studying compression dynamics in quantum machine learning, with promising implications for decision support in medical imaging workflows.
This paper presents a two-stage Hybrid Classical-Quantum (HCQ) pipeline for binary Alzheimer's disease (AD) classification from 3D T1-weighted structural MRI volumes, where the classical and quantum components are designed to complement each other rather than operate independently. A supervised 3D β-variational autoencoder (VAE) is trained end-to-end under voxel-wise reconstruction, KL-divergence, and focal classification losses that compress each 3D MRI volume (resized from 152 x 184 x 152 to 96 x 96 x 96) into a 64-dimensional latent code. Partial Least Squares (PLS) regression selects the six components in the latent code that best separate Alzheimer's Disease (AD) from cognitively normal (CN) subjects and rescales them into rotation angles, which are encoded onto a six-qubit register using the ZZ quantum feature map to give us the respective quantum states. The input to a precomputed-kernel Support Vector Machine (SVM) is an N x N Gram matrix (N = 308), created by calculating the overlap between every pair of quantum states. The novelty of this work lies in the fact that the quantum kernel operates directly on disease-aware features that are learned end-to-end by a supervised autoencoder, rather than on pre-extracted inputs. On 308 ADNI-1 subjects, consisting of 137 AD and 171 CN subjects, the baseline achieved 67.2% accuracy and 0.759 AUC, while the stability-enhanced variant reached 72.1% accuracy and 0.799 AUC with cross-fold variance halved. 3D Grad-CAM further helped validate our model's focus on brain regions linked to Alzheimer's. The HCQ pipeline could serve as a general-purpose framework for diagnostic classification across biomedical imaging domains that present similar challenges for classical approaches.
Tia Tiwari, Vamshi Krishna Kancharla, Neelam Sinha
Autoencoders transformed classical machine learning by solving the curse of dimensionality, enabling principled weight initialization and learning compact, structured representations. In this work, we extend this paradigm to quantum machine learning by introducing a variational autoencoder framework that learns task-specific quantum embeddings of classical data. We demonstrate that high-dimensional datasets, including ImageNet, can be compressed into a 13-qubit quantum representation while remaining reconstructable through a learned decoder. On MNIST (3 vs 5), our approach achieves 98.5% validation accuracy using a circuit-centric quantum classifier, within 1.2 percentage points of a classical neural network baseline (99.7%) and more than 30 percentage points above a naive amplitude-embedding approach. Unlike amplitude embeddings, which require full quantum state tomography for recovery, or angle embeddings, which generally rely on circuit inversion under restrictive assumptions, the proposed framework reconstructs the original data from only a polynomial number of measurements. The framework was further validated on IBM quantum hardware, confirming that the learned embeddings remain stable and reconstructable under real device noise.
Corrupted, inconsistent, or anomalous data silently threatens the safety and reliability of medical AI. Despite growing regulatory recognition of dataset quality assurance (QA) for high-risk medical AI, scalable automated detection remains underdeveloped. We employ unsupervised anomaly detection (AD) and out-of-distribution (OOD) detection as an automated dataset QA mechanism for multi-center dynamic contrast-enhanced breast MRI. We build a controlled AD benchmark of 17 realistic QA-relevant anomaly types from six public datasets (protocol violations, processing errors, incorrect anatomical regions) and propose a taxonomy of radiological image anomalies based on human visual perception, enabling fine-grained analysis of AD failure modes. The benchmark includes near-, medium-far-, far-OOD samples, as well as in-distribution and external normal data. Four methods are evaluated: a projection-based method extended with a domain-specific feature extractor and a novel positional encoding, a reconstruction-based approach extended to full 3D volumes with an augmented training objective, and two unmodified hybrid OOD detection methods. Medium-far- and far-OOD samples are detected reliably, whereas near-OOD samples and external normal data from unseen institutions expose method-specific differences. The 3D reconstruction-based approach best balances detection performance (AUROC: 0.936) and generalization to unseen institutions. The projection-based method with positional encoding achieves the highest overall detection performance (AUROC: 0.954). Both hybrid methods exhibit critical failure modes, confirming that methods validated for one modality or anatomy may not generalize without domain-specific adaptation. Implants and mastectomies remain an open challenge for all methods. Our results establish a foundation and practical guidance on scalable unsupervised QA in medical AI pipelines.
Chiara Tappermann, Steffen Renisch, Lars Ole Schwen +3