cs.CVJun 12, 2026

Hybrid Classical-Quantum (HCQ) Alzheimer's Classification via Supervised β-VAE and Quantum Kernels

Authors: Tia TiwariVamshi Krishna KancharlaNeelam Sinha

Abstract

This paper presents a two-stage Hybrid Classical-Quantum (HCQ) pipeline for binary Alzheimer's disease (AD) classification from 3D T1-weighted structural MRI volumes, where the classical and quantum components are designed to complement each other rather than operate independently. A supervised 3D ββ-variational autoencoder (VAE) is trained end-to-end under voxel-wise reconstruction, KL-divergence, and focal classification losses that compress each 3D MRI volume (resized from 152 x 184 x 152 to 96 x 96 x 96) into a 64-dimensional latent code. Partial Least Squares (PLS) regression selects the six components in the latent code that best separate Alzheimer's Disease (AD) from cognitively normal (CN) subjects and rescales them into rotation angles, which are encoded onto a six-qubit register using the ZZ quantum feature map to give us the respective quantum states. The input to a precomputed-kernel Support Vector Machine (SVM) is an N x N Gram matrix (N = 308), created by calculating the overlap between every pair of quantum states. The novelty of this work lies in the fact that the quantum kernel operates directly on disease-aware features that are learned end-to-end by a supervised autoencoder, rather than on pre-extracted inputs. On 308 ADNI-1 subjects, consisting of 137 AD and 171 CN subjects, the baseline achieved 67.2% accuracy and 0.759 AUC, while the stability-enhanced variant reached 72.1% accuracy and 0.799 AUC with cross-fold variance halved. 3D Grad-CAM further helped validate our model's focus on brain regions linked to Alzheimer's. The HCQ pipeline could serve as a general-purpose framework for diagnostic classification across biomedical imaging domains that present similar challenges for classical approaches.

Explore similar work

Apr 27, 2026quant-ph

Quantum Kernel Advantage over Classical Collapse in Medical Foundation Model Embeddings

We provide evidence of quantum kernel advantage under noiseless simulation in binary insurance classification on MIMIC-CXR chest radiographs using quantum support vector machines (QSVM) with frozen embeddings from three medical foundation models (MedSigLIP-448, RAD-DINO, ViT-patch32). We propose a two-tier fair comparison framework in which both classifiers receive identical PCA-q features. At Tier 1 (untuned QSVM vs. untuned linear SVM, C = 1 both sides), QSVM wins minority-class F1 in all 18 tested configurations (17 at p < 0.001, 1 at p < 0.01). The classical linear kernel collapses to majority-class prediction on 90-100% of seeds at every qubit count, while QSVM maintains non-trivial recall. At q = 11 (MedSigLIP-448 plateau center), QSVM achieves mean F1 = 0.343 vs. classical F1 = 0.050 (F1 gain = +0.293, p < 0.001) without hyperparameter tuning. Under Tier 2 (untuned QSVM vs. C-tuned RBF SVM), QSVM wins all seven tested configurations (mean gain +0.068, max +0.112). Eigenspectrum analysis reveals quantum kernel effective rank reaches 69.80 at q = 11, far exceeding linear kernel rank, while classical collapse remains C-invariant. A full qubit sweep reveals architecture-dependent concentration onset across models. Code: https://github.com/sebasmos/qml-medimage
Sebastian Cajas Ordóñez, Felipe Ocampo Osorio, Dax Enshan Koh +10
May 7, 2026cs.LG

Medical Imaging Classification with Cold-Atom Reservoir Computing using Auto-Encoders and Surrogate-Driven Training

We introduce a hybrid quantum-classical pipeline, based on neutral-atom reservoir computing, for medical image classification, focusing on the binary classification task of polyp detection. To deal effectively with the high dimensionality, we integrate a guided auto-encoder. This pipeline learns compact and discriminative representations of image data that are also well-suited for quantum reservoir computing. A key challenge in such systems is the non-differentiable nature of quantum measurements, which creates a 'gradient barrier' for standard training. We overcome this barrier by incorporating a differentiable surrogate model that emulates the quantum layer, enabling end-to-end backpropagation through the entire system. This guided training process is jointly optimized for classification accuracy and for faithful image recovery from the auto-encoder. The learned latent representations are encoded as pulse detuning parameters within a Rydberg Hamiltonian, and quantum embeddings are subsequently obtained through expectation values. These embeddings are then passed to a linear classifier. Our simulations show that this method outperforms some traditional approaches that use PCA or unguided autoencoders. We also conduct ablation studies to assess the impact of various quantum and training parameters, demonstrating the robustness and flexibility of our proposed pipeline for real-world medical imaging applications, even in the current NISQ era.
Nuno Batista, Ana Morgado, Oscar Ferraz +3
Jun 25, 2026quant-ph

Compression-Driven Anomaly Detection in Brain MRI Using an Interpretable Quantum Autoencoder

We study a quantum autoencoder (QAE) for compression-driven anomaly detection in brain MRI data. The approach leverages angle encoding to map image patches into quantum states, followed by a variational encoder-decoder architecture trained to discard information via auxiliary trash qubits. Anomaly scores reflect the degree to which inputs resist compression relative to normal data, with higher scores corresponding to deviations from the learned normal manifold. Evaluated on publicly available brain MRI DICOM datasets, the method achieves a slice-level ROC-AUC of approximately 0.95 and a patch-level ROC-AUC of approximately 0.813, outperforming classical autoencoder and PCA baselines. Analysis of the learned parameters reveals a pronounced encoder-decoder asymmetry, where effective anomaly detection arises from structured information compression within the encoder rather than increased parameter magnitude or decoder expressivity. This results in a controlled compression-reconstruction trade-off with a clear operating regime that supports principled threshold selection. Qualitative evaluation further shows that the QAE produces spatially localized anomaly heatmaps aligned with tumorous regions. The results, supported by promising baseline performances, demonstrate that quantum autoencoders provide an interpretable and controllable mechanism for anomaly detection based on incompressibility with respect to a learned latent representation. This work highlights the potential of quantum autoencoders as a principled tool for studying compression dynamics in quantum machine learning, with promising implications for decision support in medical imaging workflows.
Santanu Ganguly, Xing Liang, Dimitrios Makris