cs.CVJun 28, 2026

SonoCLIP: Mask-Guided Region-Aware Vision-Language Pretraining for Fetal Ultrasound Analysis

Authors: Hang SuChao SunZhaofan LiWei HuJuhua LiuBo Du

Abstract

Vision-language foundation models have shown strong potential in medical image analysis. Although foundation models for ultrasound imaging have recently emerged, the domain remains particularly challenging due to severe speckle noise, acquisition variability, and subtle anatomical boundaries, leading to high inter-observer variability. Existing CLIP-based models rely primarily on global image-text alignment, limiting their sensitivity to clinically decisive local structures. We propose SonoCLIP, the first million-scale region-controllable fetal ultrasound vision-language foundation model that integrates segmentation masks as mask-channel visual prompts within the vision encoder, enabling joint global-local contrastive representation learning. To support scalable region-text alignment, we introduce a sigmoid-based pairwise contrastive loss that improves stability under large-scale supervision. We further curate a 1.44M-image multimodal fetal ultrasound dataset spanning 24 standard planes for large-scale pretraining. Extensive cross-center evaluations demonstrate that SonoCLIP achieves superior zero-shot transfer performance under both global and mask-guided inference, establishing a controllable and clinically oriented foundation model for fetal ultrasound analysis. Our code and data are available at https://github.com/Harrison-one/SonoCLIP.

Explore similar work

May 4, 2026cs.CV

Ultrasound Vision-Language Alignment via Contrastive Learning

Ultrasound foundation models have achieved strong performance on structured prediction tasks but remain exclusively vision-based, limiting zero-shot and few-shot transfer to novel tasks where task-specific annotation is scarce. We address this gap with EchoCare-CLIP, a CLIP-style dual-encoder contrastive framework that aligns ultrasound images with clinical text in a shared embedding space. We curate a multi-organ corpus of over 16K image-text pairs spanning breast, liver, lung, and thyroid, with over 78% of captions derived from expert-annotated reports, and complement the remainder with a three-tier template-based and LLM-based caption generation pipeline. We evaluate model configurations spanning two text encoder families (CLIP, BioClinicalBERT) and two caption strategies (template-based, LLM-generated) against OpenAI CLIP and BiomedCLIP baselines. Our trained models consistently improve cross-modal alignment over baselines, with the best configuration achieving a paired alignment score of 0.682. However, stronger alignment does not guarantee better downstream performance: CLIP-based variants with partial fine-tuning achieve the strongest zero-shot classification on external held-out datasets (0.709 on BUSI; 0.626 on AULI), while full end-to-end fine-tuning degrades transfer due to overfitting. On linear probing and few-shot adaptation, model rankings are dataset-dependent, reflecting a trade-off between domain adaptation and representational generalizability. We further show that template-based captions match or outperform LLM-generated captions, suggesting lexical diversity is not a proxy for caption quality. Taken together, our results demonstrate that ultrasound vision-language alignment is achievable from public data alone, but robust clinical transfer requires careful balancing of domain adaptation, encoder capacity, and caption supervision quality.
Zhuoyang Lyu, Yiyang Zhang, Tongxin Wang +1
May 27, 2026eess.IV

Benchmarking Ultrasound Foundation Models for Fetal Plane Classification

Ultrasound is widely used in obstetric care due to its safety, accessibility, and real-time imaging. However, interpretation remains operator-dependent and susceptible to noise and artifacts. Deep learning models have shown strong performance to solve these problem, but they typically require large annotated datasets that are difficult to obtain in clinical ultrasound. Foundation models (FMs) offer an alternative, using a large number of ultrasound images to learn transferable representations that can generalize with limited labeled data. This work presents a comprehensive benchmark of ultrasound-specific FMs for fetal plane classification. We evaluated four ultrasound FMs (USFM, MOFO, UltraSAM, FetalCLIP) against two CNN baselines (ResNet50, EfficientNet-V2) and a ViT (DINOv3) pretrained on natural images. We trained all models under two complementary settings: full fine-tuning and linear probing with a frozen encoder. All models were trained using 5-fold patient-level cross-validation on a Spanish fetal ultrasound dataset and tested on both in-domain data and an external African cohort to assess cross-population generalization. We found that FetalCLIP achieved the best results in the linear probing setting (F1 = 0.9261 for in-domain, F1 = 0.9731 for out-of-domain), while USFM performed best in the full fine-tuning setting (F1 = 0.9476 for in-domain, F1 = 0.9515 for out-of-domain). MOFO and UltraSAM degraded most in both settings, underperforming natural image pretrained models in some cases. These findings highlight how the choice of pretrained model strongly affects fetal plane classification performance, since different pretraining objectives lead to different levels of transferability.
Leya Barrientos, Yuexi Du, Nicha C. Dvornek
Jun 9, 2026cs.CV

FADA: Accessible fetal ultrasound interpretation and annotation with a selectively distilled unified vision-language model

A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 mAP@0.50 for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.
Mahmood Alzubaidi, Uzair Shah, Raden Muaz +6