cs.CVJun 30, 2026

Fully Automated High-Precision Segmentation of Retinal Atrophy and Ellipsoid Zone Thickness in OCT: A Reliable Tool for Real-World GA Monitoring

Authors: Wolf-Dieter VoglHlynur SkulasonOliver LeingangUrsula Schmidt-ErfurthAmir SadeghipourAriadne Whitby

Organizations: RetInSight GmbH, Vienna, Austria · Laboratory of Opthalmic Image Analysis (OPTIMA), Medical University of Vienna, Austria

Abstract

Geographic atrophy (GA) secondary to age-related macular degeneration (AMD) requires precise monitoring of relevant structural biomarkers to assess disease stage, progression, and treatment response. This paper presents a fully automated, deep learning-based framework for the high-precision, pixel-wise segmentation of key biomarkers in optical coherence tomography (OCT) imaging: retinal pigment epithelium (RPE) loss, ellipsoid zone (EZ) loss, and EZ thinning. The proposed pipeline uses three specialized semantic segmentation models to delineate RPE loss, EZ boundaries (including interruptions), and Bruch's membrane. To ensure robustness and generalizability, the models were developed on a diverse dataset of 298 SD-OCT volumes representing the full phenotypic spectrum of AMD (GA:222, intermediate AMD: 40, neovascular AMD: 17, healthy: 19) and validated on an independent external dataset (n=43). The comprehensive evaluation was further strengthened using additional datasets to assess repeatability, inter-reader reliability, the impact of B-scan density on measurement accuracy, and subgroup performance stratified by lesion size. Results demonstrated high segmentation accuracy (Dice RPE loss: 0.88, Dice EZ loss: 0.87, Pearson's r > 0.99). Total EZ thickness measurements exhibited a sub-pixel average deviation of 2.15 μmμm, and segmentation reliability was confirmed by a strong reproducibility score (ICC > 0.98). By accurately and consistently quantifying outer photoreceptor degeneration and RPE loss, this fully automated framework provides a highly reliable tool for GA assessment in both clinical trials and routine real-world ophthalmic care.

Explore similar work

Jun 3, 2026cs.CV

Deep Learning-assisted AMD Staging based on OCT and OCT Angiography

To develop and evaluate deep learning models for automated grading of age-related macular degeneration (AMD) severity using optical coherence tomography (OCT) and OCT angiography (OCTA) data. Two hundred seventy-one participants aged >= 50 years with varying AMD severities. Central macular 6 x 6 mm OCT/OCTA volumes were acquired using a swept-source OCTA system (SOLIX; Visionix/Optovue Inc., CA). AMD severity was graded into four stages (No AMD, Early AMD, Intermediate AMD, and Advanced AMD) according to the AREDS simplified severity scale. Three deep learning models were developed using different input modalities: (1) biomarker maps derived from segmented pathological features, including retinal fluid, drusen, geographic atrophy (GA), and macular neovascularization (MNV); (2) two-dimensional (2D) en face OCT and OCTA projections; and (3) three-dimensional (3D) OCT/OCTA volumes. EfficientNet-based architectures were trained using normalized inputs, data augmentation, and five-fold cross-validation. A total of 2,030 OCT/OCTA volumes from 351 eyes of 271 participants were analyzed. All models demonstrated strong AMD staging performance with substantial agreement with the reference standard (QWK >= 0.83). The biomarker-based model achieved the highest overall performance (QWK = 0.85 +/- 0.03, mean +/- standard deviation) and the best detection of early AMD (F1-score = 0.59 +/- 0.14). The 3D model achieved performance comparable to the 2D OCT/OCTA model (QWK = 0.83 +/- 0.04 vs. 0.83 +/- 0.09), while the 2D OCT/OCTA model showed the highest precision (0.79 +/- 0.06) and most accurately identified eyes without AMD. Deep learning models using OCT/OCTA data can accurately and automatically grade AMD severity. Among the evaluated approaches, the biomarker-based model provided the most balanced performance and showed particular value for early AMD detection.
Yukun Guo, Tristan T. Hormel, An-Lun Wu +4
Aug 11, 2026cs.CV

Modelling Geographic Atrophy Progression using Implicit Neural Representations

Age-related Macular Degeneration (AMD) is the major cause of blindness in the Western world. Its late dry phase is characterised by irreversible atrophic areas, namely Geographic Atrophy (GA). Longitudinal Fundus Autofluorescence (FAF) image acquisitions are currently the main tool for assessing lesion growth over time at the image level. However, due to its highly individualised progression, the evolution of late AMD remains poorly understood. In this work, we propose using Implicit Neural Representations (INRs) to model GA progression at the individual level in a low-data setting. Our approach generates both FAF and GA segmentation at both past and future time points. Among the comparison models, our method achieves competitive segmentation quality across different scenarios, yielding the lowest Mean Absolute Error (MAE) for the GA lesion area and the highest DICE score, without sacrificing FAF image quality. The code is available at https://github.com/SimoneSarrocco/ga-progression-with-inrs.
Simone Sarrocco, Paul Friedrich, Florentin Bieder +4
Jul 17, 2026cs.CV

Spatial Normalization for Cross-Domain Retinal Layer Segmentation in Optical Coherence Tomography

Retinal layer segmentation in Optical Coherence Tomography (OCT) is a fundamental step for extracting quantitative biomarkers of retinal structure. Indeed, there is a growing interest in the analysis of OCTs in the context of neurodegenerative diseases. However, segmentation remains challenging due to speckle noise, shadowing artifacts, low contrast between adjacent layers, anatomical variability across subjects, and domain shifts arising from different acquisition protocols and clinical populations. While deep learning methods have achieved remarkable performance, their robustness and generalization across heterogeneous datasets remain limited. In this work, we investigate the role of spatial normalization as a preprocessing strategy to mitigate geometric domain shifts and improve the consistency of retinal layer segmentation. Inspired by standard practices in neuroimaging, we introduce a fovea-centered normalization framework that aligns OCT volumes into a common anatomical reference. We perform a comprehensive evaluation of state-of-the-art deep learning architectures. To provide a comprehensive assessment of segmentation quality, we combine conventional overlap-based metrics at B-scan level with topology-aware metrics at A-scan level and thickness-based measures at the en-face level. In cases where a ground truth is not available, we propose topology violation quantitative metrics that do not require ground truth annotations and a thickness-based qualitative assessment that captures structural consistency and clinically relevant patterns at the en-face level. The results demonstrate the importance of spatial normalization in OCT segmentation pipelines toward the development of robust and clinically meaningful retinal analysis tools, enabling reliable biomarker extraction and downstream computational analysis in neurodegenerative research.
Iker Moran-Cavero, Monica Hernandez, Elvira Mayordomo +4