cs.CVJun 30, 2026

AEGIS: A Multi-Task Joint-Embedding Predictive Architecture for Mammography

Authors: Scott Chase Waggener, Sai Karthik Navuluru, Lakshman Tamil

Organizations: Department of Electrical and Computer Engineering University of Texas at Dallas Richardson, TX

Abstract

We present Aegis, a joint-embedding predictive architecture for breast cancer detection and density assessment in mammography. We train three Vision Transformer variants (Small/Base/Large) using self-supervised joint-embedding predictive architecture (JEPA) pre-training on 71,103 studies from 14 clinical sites, followed by supervised fine-tuning with progressive resolution scaling up to 2048x1536. On a curated 785-study test set, our largest model achieves area under the receiver operating characteristic curve (AUC) 0.949 for breast cancer triage with 93% sensitivity and 75% specificity at the optimal operating point. An ensemble combining our model with a U.S. Food and Drug Administration-cleared baseline further improves discrimination to 0.952 AUC. For breast density classification, the model achieves 0.953 AUC for binary (dense vs. non-dense) classification and 62.6% exact accuracy across four Breast Imaging Reporting and Data System (BI-RADS) categories, with 98.8% adjacent accuracy comparable to reported human inter-reader agreement. External validation on the public VinDr-Mammo dataset provides evidence of cross-population transfer under a different reference standard, with the largest model achieving 0.871 AUC for triage in a zero-shot setting.

Explore similar work

Apr 21, 2026cs.CV

Attend what matters: Leveraging vision foundational models for breast cancer classification using mammograms

Vision Transformers (ViT)(\texttt{ViT}) have become the architecture of choice for many computer vision tasks, yet their performance in computer-aided diagnostics remains limited. Focusing on breast cancer detection from mammograms, we identify two main causes for this shortfall. First, medical images are high-resolution with small abnormalities, leading to an excessive number of tokens and making it difficult for the softmax-based attention to localize and attend to relevant regions. Second, medical image classification is inherently fine-grained, with low inter-class and high intra-class variability, where standard cross-entropy training is insufficient. To overcome these challenges, we propose a framework with three key components: (1) Region of interest (RoI)(\texttt{RoI}) based token reduction using an object detection model to guide attention; (2) contrastive learning between selected RoI\texttt{RoI} to enhance fine-grained discrimination through hard-negative based training; and (3) a DINOv2\texttt{DINOv2} pretrained ViT\texttt{ViT} that captures localization-aware, fine-grained features instead of global CLIP\texttt{CLIP} representations. Experiments on public mammography datasets demonstrate that our method achieves superior performance over existing baselines, establishing its effectiveness and potential clinical utility for large-scale breast cancer screening. Our code is available for reproducibility here: https://aih-iitd.github.io/publications/attend-what-matters
Samyak Sanghvi, Piyush Miglani, Sarvesh Shashikumar +3
Aug 10, 2026eess.IV

BreastMammo and DenseMammo: Benchmarks for Mammography Domain Generalization

Breast density classification is a critical component of breast cancer risk assessment, yet AI models often struggle to generalize across clinical sites due to vendor-specific acquisition styles. In this work, we introduce two new datasets, BreastMammo and DenseMammo, to facilitate robust multi-view mammography research. We propose a domain generalization framework that utilizes a foreground-only histogram matching protocol to resolve the domain shift issue arising from disparate clinical sources. Internal evaluation using a 5-fold cross-validation protocol demonstrates the efficacy of our approach, with the Swin Transformer backbone achieving a peak AUC of 98.32% for density classification. External evaluation on the TNMammo and LUMINA datasets demonstrates that the proposed approach consistently reduces domain shift, significantly outperforming prominent domain generalization paradigms, including MixStyle and Discrete-Fourier-Transform-based frameworks.
Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas +18
Aug 10, 2026cs.CV

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% mAP@.5, and 74.38% recall@.25. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% mAP@.5, and 77.32% recall@.25. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.
Dinh Tan Nguyen, Quang-Hien Kha, Le-Hoang Nguyen +8