cs.LGJul 6, 2026

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

Authors: Xiaocheng FangHaoyu WangJieyi CaiQinghao ZhaoJun LiShanwei ZhangGuangkun NieYujie Xiao+9 more

Abstract

Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption. We developed ImputeECG, a mask-conditioned one-dimensional Transformer autoencoder that completes 12-lead, 10-s ECGs while retaining all observed samples. The model was trained on PTB-XL and evaluated on PTB-XL and CPSC2018 under simulated incomplete settings, with additional real-world validation in a 43,633-record Kailuan clinical cohort after ECG image digitization. Metrics were computed over originally missing regions, with analyses of morphology and downstream diagnostic utility. On PTB-XL, ImputeECG reduced missing-region MAE by 41.7-51.0% and MSE by 54.0-63.7% versus the strongest baseline, with lower errors in R-peak timing, RR interval, QRS duration, QT interval, and P-wave, QRS-complex, and T-wave reconstruction. On CPSC2018, ImputeECG reduced MAE by 49.7-51.9%, supporting external generalization. In downstream multi-label classification, ImputeECG restored performance to 92.28% AUROC and 33.88% AUPRC in the most incomplete PTB-XL setting, approaching complete-ECG performance. On CPSC2018, completed ECGs achieved 94.75-95.89% AUROC and 78.83-81.86% AUPRC across settings. In Kailuan, ECG completion improved zero-shot sex prediction AUROC from 82.6% to 85.8% and reduced age prediction MAE from 10.72 to 9.87 years after image-based ECG digitization. These findings support ECG completion as a practical strategy for converting incomplete ECG records into AI-ready 12-lead, 10-s digital signals and extending the usable scope of ECG archives for digital cardiac assessment.

Explore similar work

Aug 13, 2026cs.LG

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.
Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
Jul 8, 2026cs.LG

ECGLight: Compute-Light Framework For Paper ECG Digitization and Myocardial Infarction Screening

Electrocardiography (ECG) is one of the most widely used tests for diagnosing cardiovascular disease. Yet several remote clinics still utilize paper ECG printouts for their analysis due to limited connectivity and computational capacity. As a result, vast numbers of physical ECGs obtained in remote areas still remain incapable of being accessed by contemporary artificial-intelligence (AI)-based decision support as they require high computational resources or strong high-speed internet connectivity. This causes several cases where conditions like acute coronary occlusion (ACS) is overlooked and reperfusion therapy delayed. Although prior work has tackled digitization and diagnosis separately, and utilized advanced AI models for them, there still remains a lack of a compute-light, on-device framework that reconstructs paper ECGs at high fidelity, while accurately supporting multiple clinically relevant endpoints. We address this need with an end-to-end lightweight on-device digitization-to-diagnosis pipeline that converts a smartphone photo or scan of a paper ECG into a calibrated 12-lead signal and screens for Myocardial Infarction (MI) pathologies, with SHapley Additive exPlanations (SHAP) to support interpretability. Trained and evaluated on 21,799 ECGs from the PTB-XL dataset and further validated on hospital-acquired ECG-Matrix dataset, the complete system runs in <30 s per ECG on CPU-only resources, achieving 95.51% accuracy (F1 = 0.9519) for MI detection on PTB-XL and 88.89% accuracy (F1 = 0.8862) for OMI detection on ECG-Matrix. This work showcases that legacy paper records can be reliably democratized in any part of the world, providing a scalable decision support when digital ECG export, connectivity, or high-end compute are unavailable
Shreyasvi Natraj, Cyrus Achtari, Felice Gragnano +3
May 25, 2026cs.AI

A Signal-Language Foundation Model for Broad-Spectrum Cardiovascular Assessment from Routine Electrocardiography

Electrocardiography (ECG) is central to cardiovascular care, but conventional AI models are often restricted to common arrhythmias and may generalize poorly across populations or clinically subtle diseases. We developed ECG Contrastive Language-Image Pre-training (ECGCLIP), a signal-language contrastive learning framework that aligns ECG waveforms with expert diagnostic reports. ECGCLIP was pre-trained on 2,837,962 ECG studies from 1,324,856 patients and evaluated on a held-out internal test set plus nine independent external cohorts comprising about 1.5 million ECGs. Evaluation covered 89 downstream tasks, including 45 ECG diagnoses, 39 echocardiographic targets, and 5 rare cardiac diseases, using PRAUC as the primary metric. ECGCLIP consistently improved performance over random initialization and Merl-R18 baselines. On the internal test set, ECGCLIP-R34 achieved strong performance for atrial fibrillation (PRAUC 0.900) and ST-segment elevation myocardial infarction (PRAUC 0.383), with robust generalization across all external cohorts. It also improved low-prevalence and diagnostically elusive diseases, including Ebstein anomaly, constrictive pericarditis, dextrocardia, and cardiac amyloidosis, with internal PRAUC values of 0.253, 0.175, 0.121, and 0.201, respectively. ECGCLIP was data efficient, matching or exceeding full-dataset baseline performance with only 10% of training data. Feature visualization and saliency analysis suggested clinically meaningful representations aligned with established electrocardiographic criteria. These findings indicate that large-scale ECG-report contrastive pre-training can expand routine ECG interpretation beyond common arrhythmias toward broad cardiovascular assessment and opportunistic screening of echocardiographic and rare conditions.
Ziqing Yu, Yuhui Tao, Jiayu Huo +19