Repairing Shape-Prior Shortcuts in Long-Range Single-Shot Fringe Projection Profilometry

Authors: Adam HaroonCody FlemingBeiwen Li

Organizations: Department of Mechanical Engineering, Iowa State University, 2529 Union Drive, Ames, 50011, Iowa, USA · College of Engineering, University of Georgia, 597 D. W. Brooks Drive, Athens, 30602, Georgia, USA

Abstract

Single-shot fringe projection profilometry (FPP) networks that regress depth directly can exploit a shape-prior shortcut, recovering depth from object boundaries rather than from fringe phase. On a photorealistic synthetic benchmark (15,600 fringe images, 50 objects at 1.5-2.1 m standoff), the best such UNet baseline plateaus at 14.54 mm object mean absolute error (MAE), and neither more data nor more capacity removes the shortcut, because neither changes the hypothesis space the optimizer searches. We introduce PhiCalNet, which outputs a wrapped-phase representation (sinφ,cosφ)(\sinφ, \cosφ) and maps it to depth through a fixed differentiable calibration layer, removing the shape-prior solution architecturally rather than by a loss penalty. Because the single-shot mapping is non-injective without fringe order, PhiCalNet takes the fringe order as auxiliary input, an assumption a sensitivity analysis shows tolerates realistic decoding error; a physics-informed (PINN) baseline with the same physics as a soft penalty yields no gain, isolating the architectural choice as the operative factor. PhiCalNet reduces object MAE 3.3x to 4.46 mm, its residual confined to 0.103% of pixels at the ±π\pmπ wrap discontinuity, and a three-frame extension reaches 1.16 mm. Two checks agree: interpretability makes phase the most decodable internal feature, and pixel-wise conformal uncertainty quantification, to our knowledge the first for FPP, localizes error at the same discontinuity, where rejecting the top 5% of pixels by snapshot disagreement cuts root-mean-square error by 64% versus 3.5% for the baseline.

Explore similar work

Jun 13, 2026cs.LG

Diagnosing Shape-Prior Shortcuts in Long-Range Single-Shot Fringe Projection Profilometry

Learning-based single-shot fringe projection profilometry (FPP) has been studied almost entirely at close range, and the networks used are evaluated only on aggregate error, leaving open whether they recover depth from fringe phase or from object-level shape cues that correlate with depth. This paper diagnoses that question mechanistically in the long-range regime (standoff beyond 1 m). Using FPP-ML-Bench, an open photorealistic synthetic benchmark (15,600 fringe images, 50 objects at 1.5--2.1 m), we first formalize why the single-shot fringe-to-depth mapping is more severely ill-posed at long range: it is non-injective without fringe-order information, and the depth error from an incorrect fringe order grows as Z2Z^2 in the working distance. Systematic ablations, extended with a multi-frame study, establish a best UNet baseline at 14.54 mm object mean absolute error (MAE), 18% of the 80 mm object depth range, with only a 1.9×\times spread across four architectures, indicating a representational rather than a capacity-bound limit. A mechanistic interpretability study, the first applied to an FPP network, localizes the cause: linear probing shows edges are 2.82×\times more decodable than depth, Grad-CAM shows attention favoring boundaries over fringes by 1.28×\times, and an in-range flat-plane test collapses a featureless plane to background depth despite valid fringes. The baseline solves the task via object-boundary shape priors rather than fringe-phase decoding. Because the shortcut is a hypothesis-space property, additional data or larger models will not remove it, motivating an architectural repair that removes the shape-prior solution by construction.
Adam Haroon, Anush Lakshman, Cody Fleming +1
Jun 10, 2026cs.CV

Spatially Coupled Phase-to-Depth Calibration for Fringe Projection Profilometry

In fringe projection profilometry (FPP), depth is commonly recovered by fitting a phase-to-depth relation independently at each camera pixel. Although such pixel-wise calibration achieves high local accuracy, neighboring pixels can acquire markedly different calibration functions even when they observe the same smooth surface, producing spatially inconsistent geometry and structured surface artifacts. We propose a spatially coupled phase-depth transformation in which all pixels share a single low-dimensional mapping-global phase scalars combined with affine spatial terms on the undistorted reference-camera grid-rather than independent per-pixel fits, optionally augmented by a bounded, spatially smooth correction field. We further introduce a native-grid pairing scheme that constructs phase-depth calibration pairs directly on the reference-camera grid: when depth supervision comes from a rectified active-stereo pipeline, planes are fitted in stereo 3D and sampled back onto the camera grid along native rays, so the phase maps are never rectified. On a dental target with high-resolution scanner ground truth, the proposed model attains point-to-surface RMSE comparable to an active-stereo reference (about 12μm aggregate) while substantially improving spatial coherence over pixel-wise polynomial and rational calibration, and reduces the runtime mapping to a few element-wise operations per pixel with negligible parameter storage.
Sehoon Tak, Jae-Sang Hyun
Jul 16, 2026cs.CV

Ray-based phase error correction for miniaturized DOE projector-based FPP under single-directional hyperbolic projection

Fringe Projection Profilometry (FPP) systems using miniaturized DOE pro-jectors often suffer from severe phase artifacts due to nonlinear projection characteristics and limited pattern controllability. We propose a ray-based phase error correction framework that models phase artifacts along projection rays from the projector pinhole, incorporating projector geometry without re-lying on image-domain processing or neighboring pixels. A projector pinhole estimation method based on a single-directional hyperbolic fringe pattern is introduced, through which projector geometry can be recovered without stereo calibration. In addition, a data-efficient strategy constructs the re-finement model from a single calibration pose. Experiments on miniaturized DOE projector-based FPP systems demonstrate significant improvements in reconstruction accuracy under nonlinear projection conditions, confirming the robustness and physical consistency of the proposed approach.
Seung-Jae Son, Yatong An, Jae-Sang Hyun