DRIFT: Difficulty-aware Rectified Flows for Through-plane MRI Super-Resolution
Authors: Yoonseok Choi, Eun-Gyu Ha, Daniel Kim, Mohammed A. Al-masni, Ming-Hsuan Yang, Dong-Hyun Kim
Organizations: Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea · Department of Bioengineering, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran, Saudi Arabia · Electrical Engineering and Computer Science, University of California at Merced, Merced, USA
Abstract
Magnetic Resonance Imaging (MRI) is often acquired with anisotropic resolution to reduce scan time, producing stair-step artifacts along the through-plane direction. In through-plane MRI super-resolution, an efficiency-fidelity trade-off arises: feed-forward regressors are fast but oversmooth at large slice-thicknesses, while sampling-based methods improve fidelity at high inference cost. We propose DRIFT, a two-stage thickness-conditioned rectified flow framework for through-plane MRI super-resolution with continuous input slice-thickness. Stage 1 employs an Anatomical Projection Network (APN) to map low-resolution patches to a coarse high-resolution manifold, providing a deterministic anatomical initialization that shortens the residual transport of Stage 2 and stabilizes slice-wise refinement. Stage 2 refines details via rectified flow and introduces a Physics-Aware Difficulty (PAD) metric derived from slice-thickness induced through-plane bandwidth deficit to guide an Adaptive Integration Scheduler (AIS), allocating ODE steps by thickness. A Consistent Endpoint Trajectory Alignment (CETA) loss enforces thickness-consistent reconstructions. Experiments show that DRIFT outperforms super-resolution baselines while reducing inference cost. Code, models, and interactive demos are available at https://yoonseokchoi-ai.github.io/drift-eccv2026/.
High-resolution (HR) MRI acquisition is often hampered by scan time constraints, resulting in anisotropic or low-resolution scans (e.g., thick-slice FLAIR) that limit diagnostic accuracy. While deep learning-based super-resolution (SR) methods show promise, they often hallucinate anatomical details, which can compromise brain structural integrity. To mitigate this limitation, we introduce MR-DiffuSR, a Multi-Resolution Diffusion-based Super-Resolution framework that incorporates HR T1w structural image priors to guide the restoration of thick-slice FLAIR scans and operates in the 3D latent space. Our architecture introduces cross-modality structural swin-attention, which derives structural attention maps from the HR T1w and applies them to the low-resolution FLAIR latent features. This design disentangles anatomical structure from modality-specific contrast, effectively preventing hallucinations. Furthermore, we employ a mixed-scale degradation strategy, training the model on a continuum of downsampling factors to ensure robustness to varying slice thicknesses, while optimizing with a DINOv3-based perceptual loss to preserve high-frequency semantic details. Evaluated on the ADNI-4 dataset, MR-DiffuSR surpasses both CNN and 2D diffusion approaches, achieving an average PSNR of 32.46dB, SSIM of 0.97, and LPIPS of 0.07 across all downsampling factors. In downstream white matter hyperintensity segmentation, our model demonstrates exceptional robustness. While baseline performance collapses at 10x down-sampling (Dice: 0.51), MR-DiffuSR maintains a Dice score of 0.63, preserving utility even at 7mm equivalent slice thickness.
Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.
Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.