cs.ROJul 21, 2026

Fabric Pneumatic Artificial Muscles Based on the Drawstring Principle

Authors: Chendong LiuDapeng YangYiming DaiLi JiangHong Liu

Organizations: State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.

Abstract

Pneumatic artificial muscles have wide applications in robotics and industrial fields. Conventional pneumatic artificial muscles generate extra radial deformation during axial contraction, which severely wastes available working space. Inspired by the widely adopted drawstring principle in textile products, this paper proposes a novel drawstring fabric pneumatic artificial muscle (DPAM). Unlike traditional counterparts, the proposed DPAM produces no extra radial deformation during contraction, greatly improving structural compactness. The DPAM exhibits outstanding mechanical performance: a load capacity over 800 times its self-weight, a maximum contraction ratio of 44%, and a power density up to 4.98 kW/kg, alongside excellent scalability. Two representative application scenarios, bionic robots and industrial production lines, are demonstrated to validate its practicability. The DPAM can be easily expanded within a two-dimensional plane, as verified by the fabricated DPAM matrix. This work not only presents a high-performance novel pneumatic artificial muscle but also inspires researchers to draw design inspiration from conventional textile structures to address existing challenges in soft robotics.

Explore similar work

May 24, 2026cs.RO

Soft Pneumatic Actuators for Soft Robotics: A Motion-Based Review of Actuation Mechanisms and Performance Trade-offs

Soft pneumatic actuators are widely used in soft robotics because they can produce large motions while remaining compliant enough to interact safely with objects, environments, and the human body. However, their performance is not solely determined by pressure. Instead, the response depends on the way the actuator is built, including the shape of its chambers, the placement of reinforcements, the use of folds, material stiffness, and the constraints that guide its deformation. As the literature has expanded, it has become more difficult to determine which mechanism is most suitable for a given application and which reported results can be compared across studies. This review examines soft pneumatic actuators according to the design strategies used to generate four motion classes: linear, bending, twisting, and omnidirectional actuation. For each class, it analyzes the structural features that define the deformation path, including braid angle, fold geometry, fiber orientation, chamber arrangement, structural asymmetry, and internal constraint layers. It then discusses how the design choice affect motion output, force generation, air demand, repeatability, durability, fabrication difficulty, and robotic integration. The review further identifies key conditions that must be considered when selecting or comparing actuators, including pressure, loading condition, actuator size, pneumatic supply, and hysteresis This approach helps explain why actuators with similar motion outputs may differ substantially in design requirements, pneumatic demand, and practical suitability. It also highlights the design priorities needed for compact, efficient, repeatable, and deployable soft pneumatic systems in wearable, biomedical, and mobile robotic applications.
Mohammed Abboodi
Apr 20, 2026cs.RO

Muscle-inspired magnetic actuators that push, pull, crawl, and grasp

Functional magnetic composites capable of large deformation, load bearing, and multifunctional motion are essential for next-generation adaptive soft robots. Here, we present muscle-inspired magnetic actuators (MMA), additively manufactured from a thermoplastic/permanent magnet polyurethane/Nd2Fe14B (TPU/MQP-S) composite using laser powder bed fusion (LPBF). By tuning the laser-energy scale between 1.0 and 3.0, both mechanical stiffness and magnetic response are precisely controlled: the tensile strength increases from 0.28 to 0.99 MPa while maintaining 30-45% elongation at break. This process enables the creation of 0.5 mm-thick flexural hinges, which reversibly bend and fold under moderate magnetic fields without damage. Two actuator types are reported showing the system versatility. The elongated actuator with self-weight of 1.57 g, magnetized in its contracted state, achieves linear contraction under a 500 mT field, lifting 50 g (32x its own weight) and sustaining performance over at least 50 cycles. Equipped with anisotropic frictional feet, it supports movement of a magnetic crawling robot that achieves up to 100% locomotion success on textured substrates. The expandable actuator exhibits reversible opening and closing under a 300 mT field, reliably grasping and releasing different objects, including soft berries and rigid 3D printed geometries. It can also anchor in a tube while holding suspended 50 g loads. This work demonstrates a LPBF-based strategy to program both stiffness and magnetization within a single material system, enabling remotely driven, reconfigurable, and fatigue-resistant soft actuators. The approach opens new possibilities for force controlled, multifunctional magnetic soft robots for adaptive gripping, locomotion, and minimally invasive manipulation of biomedical tools.
Muhammad Bilal Khan, Florian Hofmann, Kilian Schäfer +2
Apr 23, 2026cs.RO

A Compact Peristaltic Pump Based on Magneto-Elastic Hysteresis with Single Pneumatic Control

Pumping fluids is fundamental to a wide range of industrial, environmental, and biomedical applications. Among various pumping mechanisms, peristaltic pumps enable efficient and safe fluid transport by deforming an elastic tube without direct contact with the working fluid. Although previous studies have introduced mechanical, pneumatic, or magnetic actuations to drive membrane deformation, these approaches often lead to complex pump architectures and control schemes. In this study, we present a soft membrane pump that achieves peristaltic motion through a single pneumatic input combined with an embedded passive magnet. The actuation mechanism and system dynamics were analyzed and simplified through modeling. Numerical simulations were conducted to predict the internal fluid flow, and the magneto-elastic hysteresis behavior observed in the simulations was successfully validated by experiments with a proof-of-concept prototype.
Minjo Park, Metin Sitti