cs.CVJul 23, 2026

ASTRA-Net: Anatomy-Specific Transfer and Representation Alignment for Drug-Induced Sleep Endoscopy Segmentation

Authors: Suhua SunYuqiao WangSheng LiuRui FanJiajun WangRuoyan XuYixin ChenTao Li+1 more

Organizations: Department of Otolaryngology, Peking University Third Hospital, Beijing, China · Institute of Medical Technology, Peking University Health Science Center, Beijing, China · National Biomedical Imaging Center, College of Future Technology, Peking University, Beijing, China

Abstract

Quantitative drug-induced sleep endoscopy (DISE) requires reliable airway boundaries at specific anatomical levels. Pixel-level DISE annotations are scarce, and manual contouring limits the scalability of quantitative assessment. To address this limitation, we developed ASTRA-Net for known-plane DISE segmentation with limited real annotations. Stage 1 aligned intermediate ConvNeXt-Base representations from 14,250 unlabeled virtual endoscopy frames derived from computed tomography and real DISE frames. Virtual images were used only for feature alignment. Stage 2 fine-tuned four independent UNet++ decoders on 401 real annotated frames. Structured zero-mask supervision constrained incompatible plane outputs and invalid frames. Six alignment configurations used maximum mean discrepancy, domain adversarial learning, or both objectives. On a hold-out evaluation set of 100 frames, the five-model MMD-only segmentation ensemble achieved a mean Dice of 0.8927, with a 95% image-level bootstrap interval of 0.8631 to 0.9160. The mean intersection over union was 0.8239. A classification- enabled variant of the same alignment configuration reached a restricted four-plane top-1 accuracy of 0.92 on the same hold-out frames. These results indicate that ASTRA-Net can support frame-level, plane-specific DISE boundary delineation when real annotations are limited.

Explore similar work

Jul 6, 2026cs.CV

Displacement Preserving Relational Distillation for Robust Medical Segmentation

Accurate 3D medical segmentation is limited by anatomical variability and high computational costs. While knowledge distillation (KD) offers a route for model compression, conventional methods often fail to preserve complex structures and are overwhelmed by background noise. We propose Displacement-Preserving Relational Distillation (DPRD), which distills latent anatomical trajectories via vector based alignment to preserve the orientation and relative scale of the teacher's manifold, and prevents signal dilution by anchoring distillation in task-relevant structures. Integrated into nnU-Net, DPRD outperforms established baselines on ISLES 2022 and AMOS 2022 benchmarks. Notably, on the AMOS dataset, DPRD achieves a Dice score of 85.46%, edging out the high-capacity MedNeXt teacher while significantly reducing boundary errors. Despite utilizing only ~5% of the teacher's parameters and ~3% of its FLOPs, our approach maintains high structural consistency. This provides a robust, efficient solution for deploying high performance segmenters in resource-constrained clinical environments. Code: https://github.com/ClinicaAlpha/DPRD-3D-MedSeg
Zhicheng Ding, Xinyu Chu, Jung Im Choi +5
Aug 7, 2026cs.CV

DINO-3DRA: Leveraging 2D Foundation Model Semantics for 3D Cerebral Aneurysm Segmentation

Accurate aneurysm segmentation in 3D rotational angiography (3DRA) is hindered by extreme class imbalance, morphological similarity to vessels, and absent large-scale 3D pretraining. 2D vision foundation models encode dense structural priors from 1.7 billion images, yet naïve slice-wise transfer fragments anatomical continuity and destabilises optimisation. We propose DINO-3DRA, a dual-path framework achieving effective cross-dimensional semantic transfer by injecting frozen DINOv3 features into a 3D U-Net backbone via Room-Lite spatial mixing and calibrated residual fusion. On multi-centre 3DRA data, DINO-3DRA achieves state-of-the-art aneurysm segmentation (Dice: 0.758; HD95: 2.75 mm; +13% over nnU-Net) with only 5.72M trainable parameters. Ablation studies confirm that gains arise from structured cross-dimensional transfer rather than loss design alone, with bridged foundation features improving anatomical continuity between aneurysms and parent vessels. Without fine-tuning on CADA and SHINY-ICARUS, DINO-3DRA eliminates all catastrophic failure cases observed in baseline architectures, demonstrating robust generalisation across heterogeneous imaging protocols.
Jiayang Lu, Fengming Lin, Alejandro F. Frangi +1
Sep 1, 2026eess.IV

GazeRefine: Expert Gaze as a Test-Time Prompt for Training-Free Medical Image Segmentation

Medical image segmentation remains difficult to scale because high-performing methods typically rely on dense expert annotations and task-specific training. We introduce GazeRefine, a training-free framework that uses gaze as an inference-time prompt for zero-shot medical image segmentation. Sparse, duration-weighted fixations are converted into foreground and background priors that initialize semantic prototypes in frozen DINOv3 feature space. These prototypes are iteratively refined through foreground-background discrimination, feature-space affinity propagation, and anchoring to the initial gaze guidance, allowing segmentation to extend beyond directly fixated regions while limiting semantic drift. GazeRefine requires no segmentation masks, fine-tuning, adapters, prompt encoders, or gradient updates. We evaluate the method on gaze-annotated polyp segmentation and prostate MRI segmentation. The results show strong performance on colonoscopy images and competitive performance on prostate MRI, supporting gaze-guided prototype refinement as a promising approach for segmentation-label-efficient, human-in-the-loop medical image segmentation. Our tools and code can be found in the following repository: https://github.com/MohammedOussamaBEN/GazeRefine.git
Mohammed Oussama Benyahia, Marouane Tliba, Mohamed Amine Kerkouri +10