MSBraM: A Multi-scale Self-supervised Brain Foundation Model for Hierarchical EEG Dynamics Learning
Authors: Tao Zhou, Jing Han, Lingyu Shu, Zixing Zhang
Organizations: Hunan University Changsha, China
Abstract
Self-supervised foundation models have recently shown strong potential for electroencephalogram (EEG)-based analysis. However, existing approaches struggle to capture the inherently multi-scale temporal structure of EEG signals, where local neural patterns and long-range dependencies jointly encode task-relevant information. This limitation hampers cross-scale representation learning and generalization across diverse downstream tasks. To address this challenge, we propose MSBraM, a Multi-Scale self-supervised Brain foundation Model designed to learn hierarchical EEG representations. MSBraM follows a two-stage pretraining framework. First, a multi-scale neural tokenizer discretizes raw EEG signals into semantic codes at different temporal resolutions via vector-quantized reconstruction. Second, the model is pretrained to predict masked codes using a curriculum multi-scale masking strategy, progressively integrating fine-grained local patterns with global temporal context. We pretrain MSBraM on over 2,400 hours of EEG data and evaluate it across 10 downstream tasks on 12 public datasets. Extensive experiments show that MSBraM achieves superior performance on other state-of-the-art pretrained models, demonstrating strong generalization and transferability. These results indicate that explicitly modeling multi-scale temporal dynamics is critical for effective EEG foundation models.
Self-supervised pretrained foundation models (FM) have shown early promise for non-invasive electroencephalogram (EEG) decoding applications. Many recent large-scale models converged on the approach of tokenizing raw EEG followed by masked reconstruction pretraining. However, this recipe has been shown to be suboptimal for data, like EEG, with high noise amplitude and information confined to limited dimensions such as narrow frequency bands. Building on this insight, we develop a novel contrastive-pretrained EEG model with multiscale temporal convolution input layers and Transformer encoder blocks (CoCoT). CoCoT matches or beats state-of-the-art reconstruction-pretrained EEG models on extensive benchmark decoding tasks with heterogeneous electrode configurations. Furthermore, CoCoT trained from scratch outperforms previous single-task decoding models and even rivals pretrained models, showcasing the architecture's flexibility and data efficiency. Through systematic ablations, including model architecture and pretraining objective, we demonstrate the viability of contrastive learning for building EEG FMs while suggesting key architectural design considerations, prompting further investigations in alternative large-scale pretraining strategies.
Gabriel Mahuas, Victoria Shevchenko, Ugo Tanielian +2
Electroencephalography (EEG) models used for epilepsy are often limited to specific datasets and tasks. This limited approach can make it challenging to apply these models across different datasets or in various situations. However, recent studies in foundation models and self-supervised learning suggest that an adaptable EEG backbone could support a range of EEG related tasks. In this study, we have developed a multimodal EEG foundation model that combines a raw signal encoder based on the Mamba architecture, a Vision Transformer (ViT)-style encoder for time-frequency data, and a lightweight encoder for text, all within a shared embedding space. The pretraining process relies on several innovative techniques, such as masked modeling, cross-view contrastive alignment, and temporal consistency losses. These methods are designed to create rich, seizure-relevant representations without requiring labeled data. To assess the efficacy and generalization of our pretrained model, we fine-tuned it on the canonical CHB-MIT seizure detection benchmark and additional seizure detection datasets, and conducted extensive experiments comparing different model variants. On the standard CHB-MIT split, our best single model achieved an AUROC of 0.874, and an ensemble variant reached 0.878 AUROC, representing state-of-the-art performance on this benchmark. In addition to standard train-test splits, we evaluated performance under a leave-one-subject-out (LOSO) protocol, which is rarely reported in prior EEG seizure modeling work and highlights the difficulty of patient-independent seizure detection, with a mean LOSO balanced accuracy of 0.558 across 19 subjects. Across datasets and evaluation settings, our multimodal foundation model enabled robust seizure detection and straightforward adaptation to new seizure detection scenarios, while also supporting interpretable seizure localization.
Electroencephalography (EEG) foundation models aim to learn reusable representations from large-scale unlabeled recordings. A common pretraining strategy is masked waveform reconstruction, but applying supervision directly to noisy EEG may encourage models to recover predictable background activity, acquisition effects, and artifacts rather than neural structure that transfers across tasks. This raises a central question: what should an EEG foundation model predict to learn transferable representations? We introduce EEG-JEPA a structured latent-prediction framework for EEG foundation modeling. Rather than reconstructing masked voltage samples, a masked context encoder and predictor infer contextual latent states produced by an exponential-moving-average target encoder that observes the complete input. EEG-JEPA organizes target design along three complementary dimensions: target content specifies what representation is predicted, target support specifies where prediction occurs over structured electrode--time regions through Neurotopology-Aware Multi-scale Electrode-Temporal Masking (N-MET), and target depth specifies at which encoder layers supervision is applied. Together, these designs shift EEG pretraining from recovering missing measurements to inferring latent states from structured electrode--time context. We evaluate EEG-JEPA through controlled objective comparisons, frozen multitask transfer, and full fine-tuning. Under the same backbone, pretraining corpus, and training duration, EEG-JEPA improves the 14-task frozen macro balanced accuracy from 40.49% to 50.42% over CBraMod-style masked waveform reconstruction. Multi-source continuation further raises this result to 52.94%, the highest average among the EEG foundation models evaluated on EEG-FM-Bench. Under protocol-matched full fine-tuning, EEG-JEPA also improves the nine-task average balanced accuracy from 68.98% to 70.65%.