q-bio.NCJul 24, 2026

Subject-Level Heterogeneity in EEG Motor Imagery Decoding: A Large-Scale Benchmark and Portfolio-Based Reduction of the Search Space

Authors: Xavier VasquesPaul BarbasteOlivier Oullier

Organizations: IBM Technology, Bois-Colombes, France · IBM France Lab, Orsay, France · Wavestone, Paris, France · Human Technology Foundation, Paris, France · Inclusive Brains, Marseille, France · Human-Computer Interaction Department, Mohamed bin Zayed University of Artificial Intelligence, Abu Dhabi, UAE · Institute for Artificial Intelligence, Biotech Dental Group, Salon-de-Provence, France

Abstract

Robust EEG motor imagery decoding remains limited by strong inter-individual variability, making it difficult to identify pipelines that generalize across users. We present a large-scale, standardized within-session benchmark of decoding pipelines across three public datasets: Cho2017 (52 subjects), PhysionetMI (109 subjects), and Zhou2016 (4 subjects). Using a common MOABB LeftRightImagery setting, two frequency bands (8-15 Hz and 8-30 Hz), and a broad combination of feature extraction, preprocessing, and classification steps, we analyzed 216,714 raw evaluation rows, which after structured aggregation yielded 44,928, 109,000, and 4,192 subject-level observations respectively. Covariance tangent-space projection (cov-tgsp) and Common Spatial Patterns (CSP) consistently defined the strongest methodological families, though their relative ordering was dataset-dependent. On Cho2017, the best family-level mean accuracy came from cov-tgsp in 8-30 Hz (0.712 +/- 0.140), whereas Zhou2016 favored CSP (0.832 +/- 0.121 in 8-15 Hz). These aggregate rankings concealed substantial subject-level heterogeneity: 42 distinct winning pipelines across 52 Cho2017 subjects, and 93 across 109 PhysionetMI subjects. We then used the benchmark as an empirical performance landscape for building compact portfolios of pipelines of size K. Several construction procedures were compared, including a ranking-based Top-K Mean heuristic and search-based strategies. Results were broadly consistent, with Top-K Mean giving the best trade-off. A single best global pipeline already retained 94.2% of the oracle in Cho2017 and 81.8% in PhysionetMI; at K = 12, oracle retention rose to 96.5% and 90.0%. The landscape is therefore subject-dependent, and this heterogeneity can be exploited through compact portfolios that make personalization more feasible.

Explore similar work

Jun 23, 2026cs.HC

Average Rankings Mask Per-Subject Optimality: A Friedman-Nemenyi Benchmark of EEG Motor-Imagery BCI Decoders

Electroencephalography (EEG) is the dominant non-invasive modality for brain-computer interfaces (BCIs), yet reliable decoding of motor imagery is hampered by inter- and intra-individual variability. A recurring claim is that one decoding pipeline, most often a spatial or Riemannian method, is broadly preferable. We test the weakest version of that claim under the most favourable conditions. Using the Mother of All BCI Benchmarks (MOABB) framework, we evaluated 1,056 decoding configurations (feature extractor x scaler x classifier), >340,000 subject-level model fits, across three public left-versus-right motor-imagery datasets (PhysionetMI, 109 participants; Cho2017, 52; Zhou2016, 4) and two frequency bands (8-15 Hz, 8-30 Hz). Every model is fit and tested within a single session of a single participant, the easiest regime, giving every pipeline its best chance. We apply the statistics standard for multi-classifier comparison: Friedman omnibus tests, Nemenyi critical-difference analysis and Wilcoxon signed-rank tests with effect sizes. Covariance tangent-space projection (cov-tgsp) and Common Spatial Patterns (CSP) are the strongest families, but their ordering is dataset-dependent and, on the largest and most heterogeneous cohort (PhysionetMI), statistically indistinguishable (Nemenyi p = 0.27; Kendall's W = 0.11). At the individual level the single best pipeline is optimal for only 35% of PhysionetMI participants, and nonlinear descriptors are best for roughly one third; matching pipeline to participant adds about seven accuracy points over the best fixed choice. The ranking is not an artefact of dimensionality, and classifier and scaler choices are secondary to the feature representation. Even in the easiest regime, no single pipeline dominates: a lower bound on the personalization problem and a quantitative case for participant-aware model selection rather than a universal decoder.
Xavier Vasques, Paul Barbaste, Olivier Oullier
Jul 25, 2026cs.LG

Bayesian Complete-Pooling in Cross-Subject Classification for Motor Imagery Electroencephalogram

Brain-computer interfaces (BCIs) have long sought calibration-free operation, but classifiers are typically benchmarked by discrimination alone, blind to whether predicted probabilities are well calibrated - a meaningful gap given nonstationary electroencephalogram (EEG) signals and the risk of overconfident point-estimate classifiers under distribution shift. We conducted a large-scale study contrasting Bayesian complete-pooling models against frequentist baselines for cross-subject, left-hand versus right-hand motor imagery EEG classification across 20 datasets. Six frequentist pipelines were each paired with an analogous Bayesian pipeline sharing identical feature engineering, fit via Markov chain Monte Carlo posterior sampling. Our primary metric was the Brier score, decomposed into reliability and resolution, alongside AUROC for discrimination and Shannon entropy for sharpness. Each metric was analyzed via random-effects meta-analysis (REML, Knapp-Hartung adjustment), verified by leave-one-out influence analysis. Bayesian complete-pooling produced statistically but not practically significant improvements in reliability and increases in predictive uncertainty (lower sharpness); Brier score, resolution, and discrimination showed no significant differences. Between-study heterogeneity was low across all metrics, though the reliability result was sensitive to leave-one-out removal. We additionally profiled computational cost, finding that Bayesian pipelines consumed roughly thirteen times more energy than their frequentist counterparts, a cost that remains modest relative to common household appliances. These results suggest that Bayesian complete-pooling alone offers limited practical benefit for cross-subject motor imagery classification, and that partial-pooling across subjects and sessions is a more promising direction for future work.
Ethan Davis
Nov 24, 2025cs.LG

Geometry-Aware Deep Congruence Networks for Manifold Learning in Cross-Subject Motor Imagery

Cross-subject motor imagery decoding remains a fundamental challenge in EEG-based brain-computer interfaces due to substantial inter-subject variability. Recent approaches have leveraged Riemannian geometry by representing EEG signals as covariance matrices on the symmetric positive definite (SPD) manifold. However, existing methods primarily focus on manifold-based representations while largely overlooking subject-specific variations in covariance dispersion and orientation. In this work, we address these challenges through geometry-aware congruence transformations and propose three complementary models: (i) Discriminative Congruence Transform (DCT), (ii) Deep Linear DCT (DLDCT), and (iii) Deep DCT-UNet (DDCT-UNet). The proposed models are evaluated both as manifold alignment modules for downstream classifiers and as end-to-end discriminative architectures optimized via cross-entropy with a custom logistic regression head. Experiments on challenging cross-subject motor imagery benchmarks demonstrate consistent improvements in transductive decoding performance, achieving 2-3% higher accuracy than strong baselines. These results highlight the effectiveness of geometry-aware congruence learning for mitigating inter-subject variability in EEG decoding.
Sanjeev Manivannan, Chandra Shekar Lakshminarayan