cs.CVJul 27, 2026

Effect of User-Prompted Priors on Semi-Automated Cancer Lesion Segmentation in Whole-Body Computed Tomography

Authors: Isac StarkJohan ÖfverstedtElin LundströmSimon EkströmHåkan AhlströmJoel Kullberg

Organizations: Department of Surgical Sciences, Uppsala University, Sweden · Department of Surgical Sciences, SciLifeLab, Uppsala University, Sweden · Antaros Medical, Mölndal, Sweden

Abstract

In clinical oncology studies, metastatic cancer is commonly evaluated using "Response Evaluation Criteria in Solid Tumors" (RECIST), in which the diameter of up to five lesions is measured and followed over the course of treatment. However, RECIST shows limited correlation with overall survival. Total tumour volume (TTV) is a stronger predictor but typically relies on manual ground-truth segmentation of all lesions, which is time-consuming and requires expert domain knowledge. Semi-automated approaches leveraging user-prompted priors, such as bounding boxes and single-slice contours, as inputs to automated segmentation methods can facilitate the generation of ground-truth segmentations. This work investigates the impact of different user-prompted priors on semi-automated cancer lesion segmentation performance in whole-body computed tomography. Across 3-fold cross-validation and external testing, more complex spatial priors consistently improved performance, with contour priors from three orthogonal planes (axial, coronal and sagittal) achieving the best results. On the external test (n=3865 lesions), this approach achieved a mean Dice score of 0.882, compared to a mean Dice score of 0.671 for the baseline model with no spatial prior. These findings suggest that the use of multi-plane orthogonal user-prompted priors can improve semi-automated tumour lesion segmentation and support efficient generation of high-quality volumetric ground-truth data.

Explore similar work

Jun 29, 2026cs.CV

LETT-NeXt: A Lightweight RECIST-Guided Model for 3D CT Lesion Segmentation

RECIST diameter measurements are widely used for tumor response assessment, but they provide only a limited 2D description of lesion extent. We present LETT-NeXt, a lightweight RECIST-guided model that predicts 3D lesion masks from CT volumes and RECIST markers for the CVPR 2026 Foundation Models for Pan-cancer Segmentation in CT Images competition. LETT-NeXt extracts a RECIST-centered regional crop, encodes the RECIST line and endpoints as two prompt channels, and concatenates them with the CT input. A compact MedNeXt-v2 encoder--decoder predicts the lesion mask, followed by prompt-aware component selection and adaptive AutoZoom inference. On the public validation set, LETT-NeXt achieved a Dice Similarity Coefficient (DSC) of 79.4 ±\pm 10.1 and a Normalized Surface Dice (NSD) of 72.3 ±\pm 16.2. On the hidden test set, it achieved a DSC of 73.9 and an NSD of 67.3, corresponding to a challenge score of 70.6%. On the public validation mirror, LETT-NeXt completed CPU inference in 6.9 ±\pm 3.0 s per case with a peak memory use of 3.6 GB. Code is available at github.com/Ahus-AIM/lett-next.
Sebastian Aas, Elias Stenhede, Arian Ranjbar
May 22, 2026cs.CV

Exploiting Longitudinal Context in Clinician-Verified Interactive Lesion Tracking

Tracking tumor lesions across serial CT scans is essential for oncological response assessment. Existing automated methods face a fundamental trade-off: end-to-end trackers achieve high automation but offer no opportunity to correct silent tracking failures, while decoupled registration-segmentation pipelines permit user verification yet discard the lesion's prior appearance, limiting accuracy in ambiguous cases. In this work, we propose a Verified Tracking paradigm: a clinician verifies a registration-proposed prompt, which the model leverages alongside the baseline lesion appearance to resolve segmentation ambiguities. We present a unified framework combining early spatial prompt fusion with latent temporal difference weighting for longitudinally-informed segmentation. To address data scarcity, we leverage large-scale synthetic pretraining, proving essential for exploiting longitudinal context, improving performance by up to 4.5 Dice points over training from scratch. Our approach secured first place in the MICCAI autoPET IV challenge. We further curate and release PanTrack, a new longitudinal pancreatic cancer benchmark, to assess out-of-distribution generalization. Experiments show that our model outperforms prior work in both fully automatic and the proposed verified tracking setting offering a clinically safe middle ground between automation and control. Code, model and dataset will be released at https://github.com/MIC-DKFZ/LongiSeg
Yannick Kirchhoff, Maximilian Rokuss, Daniel Philipp Mertens +5
Sep 2, 2026physics.med-ph

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.
Phillip Chlap, Mark Lee, Trevor Leong +11