cs.CVJul 28, 2026

Rad-JEPA 3D: Radiology Joint-Embedding Predictive Model for 3D Computed Tomography

Authors: Quoc-Huy TrinhMinh-Van NguyenUlas Bagci

Organizations: Northwestern University · Technical University of Denmark

Abstract

Self-supervised pretraining is central to 3D medical image analysis, where unlabeled CT volumes are abundant but expert annotations are scarce. Yet existing volumetric encoders often fail to preserve the coarse spatial and geometric structure that downstream reasoning depends on, limiting their performance on organ disentanglement, abnormality detection, and spatial understanding when paired with language models. We introduce Rad-JEPA 3D, a joint-embedding predictive framework that learns volumetric CT representations by predicting the latent features of a complete scan from a masked view. At its core is a hybrid H-Mamba encoder that fuses a Mamba state-space branch, which models inter-slice continuity through sequential scanning, with a grouped-query attention branch, which captures cross-plane spatial context, combined through a lightweight per-token router. To improve the quality of intermediate representations, we further propose Hidden States Orthogonal Regularization (HSOR), which aligns student-teacher hidden states and reduces feature redundancy throughout the encoder. This layer-wise regularization produces more consistent and discriminative volumetric representations, leading to improved performance on organ recognition and spatial reasoning tasks. Pretrained on approximately 120,000 CT scans, Rad-JEPA 3D attains state-of-the-art results despite its compact size: with only 4.0B total parameters, it achieves competitive results with state-of-the-art on closed-ended VQA and the best average spatial-reasoning score on the Spatial-Med benchmark. Ablation studies confirm that the hybrid block and HSOR contribute complementary gains, and that the induced spatial structure can substitute for raw language-model scale on volumetric reasoning tasks.

Explore similar work

Jun 5, 2026cs.CV

DALE-CT: Depth-Aware Foundation Models for Computed Tomography

Recent breakthroughs in self-supervised learning (SSL), such as the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA), alongside successes in integrating visual encoders with language models, have driven the demand for adaptable, high-capacity vision encoders in Computed Tomography (CT). In this work, we explore 2D slice-based architectures as a flexible alternative to native 3D models for processing volumetric CT data. Using the CT-RATE dataset, we trained DALE-CT (Depth-Aware Latent-Euclidean Computed Tomography), a 2D model family built entirely from scratch using LeJEPA, and compared its performance against a continually pre-trained DINOv2 baseline. To enhance representation quality, we developed a novel 3D depth-aware pre-training strategy anchored by dense auxiliary supervision from both automated anatomical masks and human-annotated abnormalities. Under linear probe evaluation with Multiple Instance Learning (MIL) for multi-abnormality detection, the frozen backbone of this dual-supervised model (DALE-CT-2S) achieves a Macro AUROC of 0.833. This performance demonstrates near-parity with state-of-the-art 3D vision-language models, achieved entirely from scratch with significantly less data and no textual supervision. To ensure reproducibility, all training code, evaluation scripts, and model weights have been made publicly available.
Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty +3
May 9, 2026cs.CV

Lost in Volume: The CT-SpatialVQA Benchmark for Evaluating Semantic-Spatial Understanding of 3D Medical Vision-Language Models

Recent advances in 3D medical vision-language models have enabled joint reasoning over volumetric images and text, showing strong performance in medical visual question-answering (VQA) and report generation. Despite this progress, it remains unclear whether these models learn spatially grounded anatomy from 3D volumes or rely primarily on learned priors and language correlations. This uncertainty stems from the lack of systematic evaluation of semantic-spatial reasoning in volumetric medical VLMs for clinically reliable decision support. To address this gap, we introduce CT-SpatialVQA, a benchmark designed to evaluate semantic-spatial reasoning in 3D CT data. The benchmark comprises 9077 clinically grounded question-answer (QA) pairs derived directly from 1601 radiology reports and CT volumes, which are validated via a robust LLM-assisted pipeline with a 95% human consensus agreement rate. Our dataset requires explicit anatomical localization, laterality awareness, structural comparison, and 3D inter-structure relational reasoning. We also introduce a standardized evaluation protocol and benchmark eight 3D medical VLMs, finding severe degradation on semantic-spatial reasoning tasks, averaging 34% accuracy and often below random, highlighting the need for deeper integration of volumetric evidence for trustworthy clinical use.
Mashrafi Monon, Umaima Rahman, Asif Hanif +2
Jul 15, 2026cs.CV

Towards Enhancing 3D Spatial Reasoning in Medical Multimodal Large Language Models

While Multimodal Large Language Models (MLLMs) have demonstrated remarkable success in 2D medical image understanding, their extension to 3D volumetric imaging remains hindered by prohibitive annotation costs and dataset opacity. Current data formats, predominantly consisting of rigid Visual Question Answering (VQA) pairs or unstructured final clinical reports, typically fail to capture explicit clinical reasoning. To address this limitation, we introduce a large-scale structured reasoning dataset constructed via a novel slice-wise data synthesis paradigm. Inspired by the genuine diagnostic workflow of radiologists, this paradigm models visual cognition by decomposing the complex 3D reading process, translating global clinical priors into fine-grained, per-slice observations that are subsequently synthesized into an interpretable Chain-of-Thought (CoT). Crucially, this synthesized reasoning framework enforces essential clinical principles: sequential spatial tracking, multi-slice spatial awareness for artifact mitigation, and differential exclusion. To validate this approach, we instruction-tune a standard 2D-pretrained MLLM baseline using the synthesized data to enhance its volumetric comprehension. Comprehensive evaluations across multiple 3D medical benchmarks demonstrate that our method yields significant performance improvements over the 2D baseline. Furthermore, the resulting model exhibits robust spatial reasoning capabilities and rivals resource-intensive native 3D architectures, effectively bridging the performance gap. Ultimately, this data-centric strategy unlocks deep volumetric understanding and highly interpretable clinical logic without requiring computationally expensive 3D-specific pre-training. The complete repository, including datasets and training workflows, is publicly available at https://github.com/2020420145009/hounsfield.
Zhuoyuan Fu, Zeshang Li, Yiqiong Zhang +5