Heterogeneous computed tomography (CT) acquisitions and diverse downstream task requirements limit the transferability of fixed data preparation workflows across data sources and tasks. Existing approaches typically rely on manually designed or dataset-specific rules, making it difficult to accommodate changes in acquisition conditions and analytical objectives without manual intervention. Large language model (LLM)-based agents have shown promise for automating medical workflows, yet their potential for adaptive CT data preparation remains largely unexplored. To bridge this gap, we propose CT-PrepAgent, which enables adaptive CT data preparation through a bounded policy and controlled deterministic execution. Deterministic inspection constructs structured data--task profiles, from which a policy decides an eligible DICOM series or predefined preprocessing profile, while the controlled execution flow guards, resolves, executes, and verifies the decision with bounded recovery when enabled and safe quarantine otherwise. Across three public CT segmentation tasks, CT-PrepAgent derived data-task adaptive preprocessing decisions and achieved the highest macro-average Dice. On two private raw-DICOM cohorts, CT-PrepAgent increased verified output yield from 61.7% to 70.0% and yielded similar registration metrics on common verified outputs. Controlled fault and replay tests validate bounded recovery, safe quarantine, and policy-free replay under tested fault and drift settings.
Computed Tomography (CT) diagnosis often relies on dynamic selection of imaging phases, such as non-contrast, arterial, or venous phases, based on preliminary findings, clinical suspicion, and diagnostic guidelines. This phase-wise decision process is critical for reducing unnecessary radiation exposure while supporting timely staging and treatment planning. However, phase-selection protocols can vary across hospitals, regions, and guidelines, while most existing CT-based AI methods assume that all phases are available and focus on static tasks under a fixed imaging phase, failing to model whether additional phases are required. This limitation stems from heterogeneous multi-phase representations, the need for knowledge-guided phase control beyond visual cues, and the lack of supervision for phase-sufficiency decisions in existing datasets. To address these challenges, we propose Policy-Driven CT-Agent (PD-CTAgent) for clinically consistent CT phase selection and diagnostic reasoning. PD-CTAgent introduces a Clinical Structure Abstraction Module (CSAM) to harmonize heterogeneous CT phases into a unified, phase-aware evidence representation. Based on this representation, a Knowledge-Guided Diagnostic Control Model (KDCM) evaluates phase sufficiency and iteratively requests additional phases when necessary. The policy-driven agent design further allows PD-CTAgent to flexibly follow different institutional, regional, or guideline-specific diagnostic protocols. Together, PD-CTAgent bridges static CT analysis and real-world clinical workflows. Experiments on two public datasets, LIDC and MCT-LTDiag, and one private dataset demonstrate its effectiveness and clinical consistency. Code will be made public upon acceptance.
Computed tomography (CT) is a central to three-dimensional medical imaging, yet CT-based artificial intelligence remains fragmented across task-specific models for segmentation, classification, registration, and report analysis. Here we present FlexiCT, a family of CT foundation models trained by agglomerative continual pretraining on 266,227 CT volumes from 56 publicly available datasets, forming a large-scale public resource for CT representation learning. FlexiCT uses agglomerative pretraining across three stages: two-dimensional axial pretraining, three-dimensional anatomical pretraining and report-guided semantic alignment. This training strategy supports slice-level, volume-level and vision-language analysis. Across five downstream task families (segmentation, classification, registration, vision-language understanding and clinical retrieval), FlexiCT matches or exceeds prior task-specific approaches on multiple benchmarks. Its embeddings further organize CT scans along gradients associated with various tumor stages, suggesting that CT foundation models can capture imaging features relevant to disease phenotype characterization. Project page and code are available at: https://ricklisz.github.io/flexict.github.io and https://github.com/ricklisz/FlexiCT.
Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.
Mélanie Roschewitz, Kenneth Styppa, Yitian Tao +10