cs.CVMay 21, 2026

Universal CT Representations from Anatomy to Disease Phenotype through Agglomerative Pretraining

Authors: Yuheng LiYuan GaoHaoyu DongYuxiang LaiShansong WangMojtaba SafariJames E. BaciakXiaofeng Yang

Abstract

Computed tomography (CT) is a central to three-dimensional medical imaging, yet CT-based artificial intelligence remains fragmented across task-specific models for segmentation, classification, registration, and report analysis. Here we present FlexiCT, a family of CT foundation models trained by agglomerative continual pretraining on 266,227 CT volumes from 56 publicly available datasets, forming a large-scale public resource for CT representation learning. FlexiCT uses agglomerative pretraining across three stages: two-dimensional axial pretraining, three-dimensional anatomical pretraining and report-guided semantic alignment. This training strategy supports slice-level, volume-level and vision-language analysis. Across five downstream task families (segmentation, classification, registration, vision-language understanding and clinical retrieval), FlexiCT matches or exceeds prior task-specific approaches on multiple benchmarks. Its embeddings further organize CT scans along gradients associated with various tumor stages, suggesting that CT foundation models can capture imaging features relevant to disease phenotype characterization. Project page and code are available at: https://ricklisz.github.io/flexict.github.io and https://github.com/ricklisz/FlexiCT.

Explore similar work

Jul 29, 2026cs.CV

Anatomy Contextualized Adaption of CT Foundation Models

CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals. Fine-grained vision-language pre-training addresses this by aligning anatomy-level visual features with anatomy-specific text, but in doing so discards the global context that whole-volume models provide. Furthermore, existing fine-grained approaches train from scratch, making them computationally expensive. We introduce Anatomy Contextualized Adaptation (ACA), a lightweight framework that adapts frozen CT foundation model representations for anatomy-level vision-language alignment while enhancing global contextualization. ACA uses TotalSegmentator to decompose CT volumes into anatomy-level embeddings, which are refined via a transformer that captures cross-anatomy relationships, and aligned to both per-anatomy and scan-level text extracted from radiology reports. Evaluated on Merlin and CT-RATE, ACA consistently outperforms both the frozen foundation model baselines and existing fine-grained methods in zero-shot finding classification, while requiring less than one hour of training once embeddings are cached. The attention weights learned by ACA's inter-anatomy transformer additionally indicate plausible cross-anatomy context routing. Altogether, these results support ACA as a lightweight approach for adapting CT foundation models to anatomically grounded vision-language alignment while preserving and enhancing global anatomical context.
Roshan Kenia, Stephanie L McNamara, William Lotter
Jul 28, 2026cs.CV

OrganLens: Organ-Specific Representation Learning for CT Foundation Models

A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ. These questions require a separate representation for each organ within the same CT volume. Existing CT foundation models commonly produce a single volume-level representation, while recent anatomy-aware methods either encode pre-separated organ volumes or explicitly disentangle images into organ token groups. The former may remove clinically relevant surrounding context, while the latter does not condition a shared encoder on a selected organ before its features are formed. We introduce OrganLens for organ-specific representation learning through self-supervision. An organ identity conditions a shared CT encoder, while organ-specific distillation and anatomy-mask supervision shape features for anatomy-weighted pooling into organ-specific representations. At inference, the shared model produces 11 organ-specific representations without external segmentation masks. We evaluate OrganLens on CT-RATE, RAD-ChestCT, INSPECT, and NLST across diverse acquisitions and downstream evaluations. Relative to CT-pretrained DINOv2, heart representations raise CT-RATE cardiomegaly AUROC from 0.910 to 0.953, while lung representations improve the Harrell C-index for NLST lung-cancer mortality by 14.2%. The global representation reaches INSPECT Recall@10 of 33.09% and 32.04% for text-to-image and image-to-text retrieval, respectively. Across organ-related tasks, anatomically matched representations provide stronger task-relevant signal, while the global representation retains broad utility. OrganLens offers a scalable approach to organ-specific CT representation learning with a shared encoder. More broadly, it provides the medical research community with a reusable framework for studying organ-specific disease across cohorts and clinical endpoints.
Zhixuan Ge, Anqi Li, Sadeer Al-Kindi +2
Jun 5, 2026cs.CV

DALE-CT: Depth-Aware Foundation Models for Computed Tomography

Recent breakthroughs in self-supervised learning (SSL), such as the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA), alongside successes in integrating visual encoders with language models, have driven the demand for adaptable, high-capacity vision encoders in Computed Tomography (CT). In this work, we explore 2D slice-based architectures as a flexible alternative to native 3D models for processing volumetric CT data. Using the CT-RATE dataset, we trained DALE-CT (Depth-Aware Latent-Euclidean Computed Tomography), a 2D model family built entirely from scratch using LeJEPA, and compared its performance against a continually pre-trained DINOv2 baseline. To enhance representation quality, we developed a novel 3D depth-aware pre-training strategy anchored by dense auxiliary supervision from both automated anatomical masks and human-annotated abnormalities. Under linear probe evaluation with Multiple Instance Learning (MIL) for multi-abnormality detection, the frozen backbone of this dual-supervised model (DALE-CT-2S) achieves a Macro AUROC of 0.833. This performance demonstrates near-parity with state-of-the-art 3D vision-language models, achieved entirely from scratch with significantly less data and no textual supervision. To ensure reproducibility, all training code, evaluation scripts, and model weights have been made publicly available.
Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty +3