Synthetic power-grid scenarios are essential for planning, resilience assessment, contingency analysis, and data-driven power-system applications. Recent synthetic grid generation methods have improved structural realism and operational feasibility by incorporating engineering knowledge through post-generation validation, optimization, or physics-aware generation. However, generated scenarios may still exhibit low AC feasibility and robustness, limiting their practical value for downstream power-system studies. This paper proposes a feasibility-aware distribution-learning framework that learns the AC-operable joint distribution of network topology, branch electrical parameters, and time-varying load profiles. Instead of enforcing feasibility after generation, the proposed framework incorporates AC power-flow convergence and operational constraints into hierarchical diffusion-based distribution learning. This enables the generator itself to produce operationally feasible grid scenarios through efficient diffusion sampling. The hierarchical architecture decomposes the high-dimensional generation task into three engineering-motivated stages: topology and bus-attribute generation, branch-parameter generation conditioned on the generated structure, and load-profile generation conditioned on both network structure and electrical characteristics. Experiments on benchmark systems demonstrate that the proposed framework significantly improves operational feasibility and contingency robustness while maintaining strong statistical fidelity and eliminating optimization-based post-processing.
The increasing uncertainty from flexible demand and renewable generation has made distributionally robust optimization (DRO) an important tool for robust power system dispatch. DRO relies on forecast scenarios to construct ambiguity sets, but conventional scenario generation pipelines are often trained in an accuracy-oriented manner and may neglect spatial correlations among uncertainties. This mismatch can produce ambiguity sets that are statistically plausible but suboptimal for downstream operation. This work proposes a decision-focused generative framework for correlated scenario generation in DRO-based dispatch. Instead of training generative models solely to fit the historical uncertainty distribution, the proposed framework optimizes generated scenarios according to their induced downstream operational cost. The proposed framework is tailored to mainstream generative models, including variational autoencoders, generative adversarial networks, and diffusion models, while capturing the joint distribution of uncertainties across buses. To improve computational tractability, we further develop a differentiable scenario selector that selects decision-relevant scenarios from a generated pool and can be trained within the same decision-focused pipeline. Case studies demonstrate that the proposed framework effectively reduces 0.80%-2.02% operational cost across different generative models compared to accuracy-oriented methods.
AC Optimal Power Flow (ACOPF) and Security-Constrained Unit Commitment (SCUC) are fundamental optimization problems in power system operations. ACOPF serves as the physical backbone of grid simulation and real-time operation, enforcing nonlinear power flow feasibility and network limits, while SCUC represents a core market-level decision process that schedules generation under operational and security constraints. Although these problems share the same underlying transmission network and physical laws, they differ in decision variables and temporal coupling, and prior learning-based approaches address them in isolation, resulting in disjoint models and representations.We propose a learning framework that jointly models ACOPF and SCUC through a shared graph-based backbone that captures grid topology and physical interactions, coupled with task-specific decoders for static and temporal decision-making. Training includes solver supervision with physics-informed objectives to enforce AC feasibility and inter-temporal operational constraints. To evaluate generalization, we assess cross-case transfer on unseen grid topologies for ACOPF and SCUC without retraining, and systematic generalization on the UC-ACOPF problem using unsupervised, physics-based objectives and a power-dispatch consensus mechanism. Experiments across multiple grid scales demonstrate improved performance and transferability relative to existing learning-based baselines, indicating that the model can support learning across heterogeneous power system optimization problems.
AC optimal power flow determines the minimum-cost generation dispatch under nonlinear power balance constraints and is solved thousands of times daily in electricity market operations. Learning a direct mapping from load conditions to OPF solutions can accelerate this computation, yet with deepening renewable penetration, a single optimal dispatch is no longer sufficient. Operators require a characterization of the distribution of feasible near-optimal solutions for risk quantification, sensitivity analysis, and multi-objective trade-off assessment. Supervised neural networks provide fast point predictions but cannot capture this conditional distribution. Diffusion-based generative models can sample diverse solutions in principle, yet existing methods operating in the raw state space exhibit degraded solution quality and fail to scale beyond medium-sized systems. We identify the root cause as the conflation of two distinct tasks within a single model. Compressing the high-dimensional OPF solution manifold is one task, and learning the conditional mapping from loads to that manifold is another. This paper presents FMOPF, a framework that resolves this conflation by decoupling compression from generation through latent flow matching and by explicitly modeling load-state coupling through a Constraint-Aware Interaction Prior Network. Experiments on four IEEE test systems demonstrate that FMOPF provides the most effective Newton-Raphson warm starts, achieves the lowest tail risk among generative methods, and is the first such method to scale to systems with several hundred buses while preserving full feasibility. Ablation studies confirm that the latent generation pipeline is a necessary condition for physical feasibility and that the interaction prior functions as a late-stage tail-risk controller.