cs.CVAug 11, 2026

Rethinking LLM Verification: Evidence Structure, Uncertainty, and Selective Refinement

Authors: Uma RanjanKunal TilaganjiAditya KoulAnurag MahipalDashpreet SinghHriday RanaManan JainSidharth Gupta+4 more

Organizations: Indian Institute of Technology Jammu · Microsoft Research · SCB Dental College and Hospital, Cuttack

Abstract

Large language models (LLMs) often rely on shortcuts rather than systematic reasoning, raising safety concerns in medical applications. Allowing models to abstain when uncertain improves reliability but introduces a coverage accuracy tradeoff. We propose a two-stage framework for medical hypothesis verification in multiple-choice settings that manages this tradeoff through targeted ontology grounding, applied only when the model abstains. We show that abstention is not random but reflects genuine uncertainty, with abstained predictions associated with lower confidence. Across two frontier models (GPT-5.5, accessed via the Azure OpenAI API, and DeepSeek-R1), the proposed framework improves question-level accuracy by 9.6 percentage points (82.9% to 92.5%) and hypothesis-level accuracy by 4.2 percentage points (92.0% to 96.2%). Our experiments conducted on MedReason and MedQA show that abstention can be repurposed as a control signal for selective reasoning refinement, achieving knowledge-graph-level performance without explicit knowledge graph construction.

Explore similar work

May 1, 2026cs.CL

CLEAR: Revealing How Noise and Ambiguity Degrade Reliability in LLMs for Medicine

Medical large language model (LLM) evaluations rely on simplified, exam-style benchmarks that rarely reflect the ambiguity of real-world medical inquiries. We introduce the CLinical Evaluation of Ambiguity and Reliability (CLEAR) framework, which assesses how decision-space presentation, ambiguity, and uncertainty affect LLMs' reasoning on medical benchmarks. CLEAR systematically perturbs (1) the number of plausible answer options, (2) the presence of a ground truth or abstention option, and (3) the semantic framing of answer options. Applying CLEAR on three benchmarks evaluated across 17 LLMs reveals three notable limitations of existing evaluation methods. First, increasing the number of plausible answers degrades a model's ability to identify the correct answer and abstain against incorrect ones. Second, this lack of caution intensifies as the framing of abstention shifts from assertive rejection like "None of the Above" to uncertainty admission like "I don't know" (IDK). Notably, just including IDK in the answer space increases incorrect answer selections. Lastly, we formalize the performance gap between identifying the correct answer and abstaining from incorrect ones as the humility deficit, which worsens with model scale. Our findings reveal limitations in standard medical benchmarks and underscore that scaling alone does not resolve LLM reliability issues.
Kevin H. Guo, Chao Yan, Avinash Baidya +5
May 6, 2026cs.LG

NoisyCoconut: Counterfactual Consensus via Latent Space Reasoning

This paper presents NoisyCoconut, a novel inference-time method that enhances large language model (LLM) reliability by manipulating internal representations. Unlike fine-tuning methods that require extensive retraining, NoisyCoconut operates directly on model representations during inference and requires no retraining. Rather than training models to reason in latent space, we inject controlled noise into latent trajectories to generate diverse reasoning paths. Agreement among these paths provides a confidence signal, enabling models to abstain when uncertain. We demonstrate that this approach achieves effective coverage-accuracy tradeoffs across multiple reasoning benchmarks without requiring access to training data or modification of model parameters. This approach provides a practical pathway to improving the reliability of LLM outputs while maintaining compatibility with existing models. Our experiments show that unanimous agreement among noise-perturbed paths reduces error rates from 40-70% to below 15%, enabling models to exceed 95% accuracy on mathematical reasoning tasks through selective abstention.
Michael Jerge, David Evans
Aug 10, 2026cs.CL

When Confidence Fails: Overconfidence in LLMs under Uncertainty and Missing Clinical Information

Large Language Models (LLMs) have achieved strong performance in medical question answering and clinical reasoning tasks. However, their reliability under uncertainty remains poorly understood which raises critical concerns for deployment in high-stakes clinical settings. In such environments, incorrect predictions are inherently risky, but confident incorrect predictions can be particularly harmful as they may mislead clinical decision-making. In this paper, we conduct a systematic behavioral analysis of LLMs under clinical information uncertainty. We propose an evaluation framework based on the MedMCQA dataset consisting of two complementary uncertainty settings. First, we introduce linguistic uncertainty cues through prompt modifications to simulate ambiguous clinical contexts. Second, we construct an answer removal setting, wherein the correct option is deliberately excluded mandating the model to recognize insufficient information and abstain. We analyze both model accuracy and confidence behavior using multiple calibration metrics including calibration gap, Expected Calibration Error (ECE), and Unsafe Confident Error Rate (UCER) across 500 medical questions. Our results reveal a consistent failure mode, i.e., although accuracy degrades under increasing uncertainty, model confidence remains misaligned with accuracy. This leads to a substantial increase in unsafe confident errors, indicating that model confidence remains largely insensitive to clinically meaningful information loss. Furthermore, we observe significant variation across models in their ability to abstain when the correct answer is unavailable, with some models persistently producing high confidence hallucinated answers. These findings expose critical limitations in the epistemic reliability of current LLMs and highlight the need for uncertainty aware evaluation methods prior to their deployment in clinical workflows.
Maryam Tahermazandarani, Adnan Mahmood, Fahmida Islam +1