cs.CVAug 13, 2026

Reliability analysis for BraTS-GoAT segmentation: a controlled robustness study of deep-ensemble uncertainty

Authors: Riya Deepak ShetLe Zhang

Abstract

Deep networks segment brain tumours accurately in-distribution, but can fail silently when the input differs from their training data. That risk is central to clinical deployment and is the premise of the BraTS-GoAT generalizability task. We ask not only how well a model segments, but whether its uncertainty knows when it is wrong. On BraTS-GoAT (Task 3) we train a 5-fold cross-validated nnU-Net baseline (one held-out prediction per case) and a 3-seed deep ensemble. Both are evaluated for calibration and error detection on a per-region relevant mask, aggregated per case. In-distribution the 3-seed ensemble improves modestly over the already strong single model on the same held-out split, with the clearest gain in calibration. The separation appears under shift. In a controlled robustness study using graded synthetic corruptions as a proxy for acquisition shift, the single model's confidence stays flat while its accuracy and calibration degrade. Inter-member disagreement instead rises steeply, about a quarter to a third above the clean condition, several times the single model's response. On the official validation leaderboard the 5-fold ensemble of those folds attains whole-tumour Dice 0.87. The generalization gap is concentrated on the harder regions, with a characteristic failure of missing small, satellite lesions on unseen cohorts. In the synthetic study, disagreement among the 3-seed members is a more sensitive case-level indicator of acquisition shift than single-model confidence. Its per-voxel error localisation weakens as severity grows. The contribution is a rigorous, honest reliability comparison rather than a claim that any one uncertainty method dominates.

Explore similar work

Sep 14, 2026cs.CV

Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026

BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.
Tristan Kirscher, Vivian Metzger, Philippe Meyer +1
Jul 22, 2026cs.CV

Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation

Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may all alter model behavior without producing an obvious warning. We present a reproducible framework for evaluating uncertainty-aware segmentation under con- trolled clinical degradation. Our experiments use a synthetic multimodal brain tumor MRI cohort generated with a biophysical phantom simulator that follows the BraTS protocol. We train U-Net and Attention U-Net baselines for multi-class tumor sub-region segmentation and augment both models with Monte Carlo dropout to estimate per-voxel uncertainty. Across eight clinically motivated corruption types at five severity levels, we measure segmentation accuracy, calibration, failure detection, and selective prediction coverage. On clean data, Attention U-Net achieves a whole-tumor Dice of 0.990; under severe Gaussian noise, its performance falls to 0.089. Predictive uncertainty rises with degradation and tracks segmentation error (Pearson r = 0.53 under severity-3 Gaussian noise), allowing us to flag failures with an AUROC of 0.843. These results argue for uncertainty-aware inference as a practical safety layer in physician-in-the-loop radiology workflows. We release the code, trained models, and evaluation protocol to support direct reproduction.
Pranav Kaliaperumal, Manisha Kaliaperumal
Jun 17, 2026cs.CV

Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation

Glioma segmentation in multiparametric MRI is a critical component of treatment planning. A segmentation model that fails silently on treatment-critical sub-regions represents a patient safety risk that overlap-based metrics such as Dice scores cannot expose. We ask whether voxel-level uncertainty estimation via Monte Carlo (MC) Dropout can reliably identify segmentation errors in clinically critical sub-regions, and whether calibration failure modes are detectable from standard reporting metrics alone. In an empirical two-model case study on 126 BraTS21 patients, we evaluate a high-performance pretrained SegResNet and a locally trained UNet with residual units (UNet-Res). MC dropout preserved segmentation accuracy (ΔDice|Δ\text{Dice}| <0.01<0.01) while achieving strong uncertainty-error alignment (AUROC for entropy (H) \approx0.97), indicating uncertainty correctly ranks erroneous voxels above correct ones. Entropy-based patient stratification identified a high-uncertainty subgroup with substantially lower segmentation performance (median whole-tumour Dice 0.8350.835 vs. 0.9250.925), supporting uncertainty as a practical triage signal. However, global alignment can mask important region-specific differences. Despite similar AUROC, UNet-Res exhibited near-zero enhancing tumour entropy (0.0540.054) and Expected Calibration Error (ECE) of 0.9150.915, with a Dice of only 0.7140.714, indicating severely miscalibrated confidence on the most clinically critical sub-region, a failure mode invisible to standard Dice and AUROC reporting. These findings demonstrate that strong uncertainty-error alignment is necessary but insufficient for clinical safety: sub-region-specific calibration assessment must accompany AUROC evaluation when selecting models for clinical deployment.
Xin Ci Wong, Duygu Sarikaya, Kieran Zucker +2