eess.IVAug 15, 2026

Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading

Authors: Saksham Kumar

Organizations: Department of Computer Science & Engineering, Indian Institute of Technology Patna, Patna, Bihar, 801106, India

Abstract

Automated five-stage diabetic retinopathy (DR) grading requires more than high accuracy alone. Medical-grade deployment calls for lesion-aware preprocessing, ordinal predictions, calibrated uncertainty, and explainability to support reliable diagnostic systems. We present a unified pipeline that addresses these requirements using a Ben-Graham-green-channel CLAHE feature representation, an EfficientNetV2-L ordinal regressor, and Monte Carlo dropout for uncertainty-driven referral. Grad-CAM provides visual explanations aligned with clinically relevant lesions. The proposed method achieves a QWK of 91.31% on the APTOS-2019 official test split, placing it within the near-perfect agreement band (>80%). At a 20% referral rate, 293 of 366 images are automatically graded with a QWK of 90.40%. More complex cases are referred for specialist assessment, demonstrating a practical trade-off among grading quality, automation, and patient safety in robust, reliable, and deployment-ready medical diagnostic systems.

Figures & tables

Explore similar work

Oct 13, 2026

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.
Mar 12, 2026

Diabetic Retinopathy Grading with CLIP-based Ranking-Aware Adaptation:A Comparative Study on Fundus Image

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated fundus image grading can play an important role in large-scale screening. In this work, we investigate three CLIP-based approaches for five-class DR severity grading: (1) a zero-shot baseline using prompt engineering, (2) a hybrid FCN-CLIP model augmented with CBAM attention, and (3) a ranking-aware prompting model that encodes the ordinal structure of DR progression. We train and evaluate on a combined dataset of APTOS 2019 and Messidor-2 (n=5,406), addressing class imbalance through resampling and class-specific optimal thresholding. Our experiments show that the ranking-aware model achieves the highest overall accuracy (93.42%, AUROC 0.9845) and strong recall on clinically critical severe cases, while the hybrid FCN-CLIP model (92.49%, AUROC 0.99) excels at detecting proliferative DR. Both substantially outperform the zero-shot baseline (55.17%, AUROC 0.75). We analyze the complementary strengths of each approach and discuss their practical implications for screening contexts.
Apr 25, 2026

From Pixels to Explanations: Interpretable Diabetic Retinopathy Grading with CNN-Transformer Ensembles, Visual Explainability and Vision-Language Models

The quality of diabetic retinopathy (DR) screening relies on the ability to correctly grade severity; however, many deep-learning (DL) classifiers cannot be easily interpreted in the clinical context. This study presents a methodology that combines strong discriminative models with multimodal explanations, converting retinal pixels into clinically interpretable outputs. Using the APTOS 2019 benchmark, we evaluated six representative CNN- and transformer-based backbones under a controlled protocol with stratified five-fold cross-validation. We then compared ensembling strategies (hard voting, weighted soft voting, stacking) and investigated a hybrid class-level fusion variant to exploit grade-specific advantages. For interpretability, we produced Grad-CAM++ visual attribution maps and short textual rationales using vision-language models (VLMs) conditioned on the fundus image and classifier outputs under conservative prompting constraints. Modern CNN backbones (ResNet-50 and ConvNeXt-Tiny) provided the strongest single-model baselines, with cross-validated QWK up to 0.919 and 0.914, respectively. Ensembling improved ordinal agreement, and weighted soft voting was the most consistent across folds (QWK 0.934 +/- 0.017). Hybrid class-level fusion was competitive but did not yield a statistically reliable improvement over standard fusion in paired fold comparisons (Holm-adjusted p >= 1.000). For explanation quality, Grad-CAM++ offered plausible but coarse localization, and VLM rationales were generally grade-consistent. Quantitatively, VLM variants showed a trade-off between clinical completeness and template-level semantic similarity (coverage 0.700 vs. BERTScore 0.072), while image-text alignment was comparable (CLIPScore approximately 0.34).