Self-Supervised Noise2Noise-Enhanced Denoising for Continuous-Scan Air-Plasma THz Spectroscopy
Authors: Adam Umra, Oways Alsoloh, Oliver Nagy, Aydin Sezgin, Clara Saraceno
Organizations: Institute of Digital Communication Systems, Ruhr University Bochum, Germany · Photonics and Ultrafast Laser Science, Ruhr University Bochum, Germany
Terahertz time-domain spectroscopy (THz-TDS) based on air-plasma generation and balanced air-biased coherent detection offers gap-free broadband coverage, but individual continuous-scan traces are strongly affected by pulse-to-pulse fluctuations and electronic noise. Reaching a useful signal-to-noise ratio therefore requires averaging multiple traces, which directly increases measurement time. We propose a learned denoising approach that recovers high-quality THz waveforms from as few as one complete continuous delay sweep, referred to here as a single-scan trace. A compact one-dimensional residual U-Net is trained using two complementary strategies: a reference-supervised baseline that maps individual noisy traces to long-average reference waveforms, and a Noise2Noise approach that learns from pairs of independently acquired noisy traces without requiring a clean training target. Averaging the predictions of both models reduces systematic bias and yields a trace-reduction factor of approximately 5.4× at K=1, meaning that one denoised trace achieves the reconstruction accuracy of averaging approximately five raw traces. The Noise2Noise model alone achieves 4.9×, outperforming both the reference-supervised baseline (4.6×) and classical Wiener filtering (3.2×). These results show that self-supervised learning from repeated noisy measurements can support faster continuous-scan THz-TDS without hardware modification.
Figures & tables
Fig. 1: Proposed denoising framework. Two independently trained residual U-Nets use reference-supervised and Noise2Noise targets, respectively. Their predictions are averaged to obtain the ensemble estimate.
Fig. 2: Qualitative comparison on the held-out acquisition. Top: Time-domain waveforms for the long-average reference, a representative raw single trace, and the mean predictions of the reference-supervised, Noise2Noise, and ensemble models. Bottom: Corresponding one-sided magnitude spectra, normalized to the peak of the long-average reference.
Fig. 3: Residual analysis on the held-out acquisition. Top : time-domain residual (denoised mean − reference). Bottom : normalized spectral error ∣F{x^}−F{xˉ}∣/max∣F{xˉ}∣ .
Method
RMSE
SNR gain (dB)
Raw single trace
0.293
0.00
Wiener filter
0.164
5.07
(a) Reference-supervised
0.137
6.63
(b) Noise2Noise
0.132
6.91
(a)+(b) Ensemble
0.126
7.31
TABLE I: single-scan trace( K=1 ) reconstruction quality on the held-out acquisition. Lower RMSE and higher SNR gain are better; the raw single trace defines the 0 dB reference.
Fig. 4: K -sweep evaluation on the held-out acquisition. Top : RMSE vs. number of averaged traces K ; error bars show ±1 standard deviation over 500 random subsets. Bottom : trace-reduction factor ρ(K)=Keq/K ; dashed line marks break-even with raw averaging.
A lightweight and reproducible denoising pipeline for high-throughput Raman spectroscopy is presented. The approach relies on a one-dimensional convolutional autoencoder trained using a Noise2Noise strategy, requiring neither external spectral libraries nor high signal-to-noise reference spectra for training. From a reduced training subset composed of repeated short-exposure acquisitions, the model learns to reconstruct Raman spectra while efficiently suppressing stochastic noise. The method is evaluated on a heterogeneous mineral sample, using both quantitative spectral fidelity metrics (RMSE, SNR, SSIM) and task-oriented criteria based on unsupervised K-means classification. Results demonstrate that integration times as short as 5 ms per spectrum, which are typically insufficient for reliable interpretation, yield denoised spectra with high fidelity to the reference data while preserving chemically coherent maps. This work provides a practical trade-off between spectral quality and acquisition speed, enabling fast, adaptable Raman workflows compatible with routine laboratory use. It also offers a transferable framework for other one-dimensional spectroscopic modalities.
David Martin-Calle, Cesar Alvarez Llamas, Vincent Motto- Ros +3
ILM,UCBL,CNRS · Universit´e Claude Bernard Lyon 1, CNRS, Institut Lumi`ere Mati`ere, F-69622 Villeurbanne, France · ILM,UCBL,CNRS,IUF +1
The inherent electronic and speckle noise complicates clinical interpretation of ultrasound images. Conventional denoising methods rely on explicit noise assumptions whose validity diminishes under composite noise conditions. Learning-based methods are usually pretrained in a limited image domain using a labeled dataset, which implies inevitable domain shift in complex in vivo environments. This study proposes a Pyramid Self-Contrastive Learning (PSCL) framework for test-time ultrasound image denoising without pretraining. Given multiple noisy samples from only one-shot imaging, PSCL disentangles anatomical similarity and noise randomness into separate pyramid latent spaces. The clean image is then decoded from the anatomy space while discarding the noise space. We first apply PSCL to synthetic aperture ultrasound (SAU), where an Aperture-to-Aperture loop serves as a self-supervised proxy task to ensure denoising fidelity. Simulation experiments, including noise levels from 0 to 30 dB and inclusion geometries from simple to complex, demonstrated improvements of 69.3% in SNR and 34.4% in CNR. The in vivo results showed 84.8% SNR and 25.7% CNR gains using only two aperture data of the heart in six echocardiographic views, liver, and kidney. PSCL delivers clear images across diverse imaging targets and configurations, paving the way for more reliable anatomical visualization without domain shift and pretraining costs.
Jiajing Zhang, Bingze Dai, Xi Zhang +2
Department of Electrical and Computer Engineering, The University of Hong Kong, Hong Kong · Department of Biomedical Engineering, Duke University, North Carolina, United States
Next-generation fusion facilities like ITER face a "data deluge," generating petabytes of multi-diagnostic signals daily that challenge manual analysis. We present a "signals-first" self-supervised framework for the automated extraction of coherent and transient modes from high-noise time-frequency data across a variety of sensors. We also develop a general-purpose method and tool for extracting coherent, quasi-coherent, and transient modes for fluctuation measurements in tokamaks by employing non-linear optimal techniques in multichannel signal processing with a fast neural network surrogate on fast magnetics, electron cyclotron emission, CO2 interferometers, and beam emission spectroscopy measurements from DIII-D. Results are tested on data from DIII-D, TJ-II, and non-fusion spectrograms. With an inference latency of 0.5 seconds, this framework enables real-time mode identification and large-scale automated database generation for advanced plasma control. Repository is in https://github.com/PlasmaControl/TokEye.
Nathaniel Chen, Kouroche Bouchiat, Peter Steiner +6