eess.SPAug 31, 2026

Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

Authors: Navaneeth Krishnan KamalakannanJanakiraman KamalakannanHarinisri Velmurugan

Abstract

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless losses, energy constraints, and edge-computation latency. We introduce Physiological Information Reliability (PIR), a cross-layer framework that represents physiological information value jointly with wireless, energy, and computation states and uses a contextual bandit to adapt sensing and communication decisions. We integrate multimodal ECG/PPG signal-quality estimation with physiological information value and an adaptive network-coding layer under burst-erasure conditions. Across controlled multiseed experiments, PIR-LinUCB demonstrates a promising low-energy operating point while maintaining medical latency constraints and competitive physiological estimation performance relative to fixed and heuristic policies. We analyze the resulting accuracy-energy-latency trade-offs and identify limitations of proxy PIV estimation and simulated communication dynamics. These results provide an initial computational demonstration of physiological-information-aware resource allocation and motivate future clinical and real-channel validation.

Explore similar work

Aug 7, 2026eess.SP

CFD-Guided Detection of Concept Drift in Multimodal Physiologic Signals

Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration. This paper asks when a model should keep its prediction, change it, or flag uncertainty. We propose a physiologic stability framework, called PECS, that compares changes inside the model with measurable changes in the signal. ECG is treated as the main cardiac signal, photoplethysmography (PPG) adds pulse and vascular information, and respiration is used only when ECG and PPG disagree. We test the framework on PTB-XL at pilot and full scales and on synchronized BIDMC and MIMIC waveform cohorts. The PTB-XL pilot and full- scale analyses selected different domain pairs, and the strongest cross-modal pair also changed across BIDMC and MIMIC, showing that adding every available signal is not always the best choice. PECS outperformed the evaluated drift-detection baseline implementations, reaching drift classification accuracy (DCA) of 0.8786 on expanded BIDMC and 0.9560 on MIMIC. The MIMIC results also showed that respiration can help during disagreement cases, but it should be used selectively rather than as an automatic override. Overall, the results support PECS as a candidate monitoring framework for wearable cardiovascular AI while highlighting the need for scale-aware domain selection and interpretable trust routing
Farouk Ganiyu Adewumi, Timothy Oladunni, Rochak Ghimire +3
May 10, 2026cs.LG

Biosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model

Cardiovascular disease remains the leading cause of global mortality, yet scalable cardiac monitoring is hindered by the gap between diagnostic-rich ECG and ubiquitous wearable PPG. Bridging this gap requires representations that are compact, transferable across modalities and devices, and deployable without task-specific retraining. Here we introduce biosignal fingerprints: compact latent representations of cardiovascular state derived from a cross-modal foundation model, the Multi-modal Masked Autoencoder (M2AE), trained on over 3.4 million paired ECG and PPG signals. M2AE integrates modality-specific encoders with a shared bottleneck and dual decoders, jointly optimized using reconstruction and cross-modal contrastive objectives, yielding generalizable fingerprints that retain intra- and inter-modality features. Like a biometric fingerprint, these representations uniquely encode an individual's cardiovascular state in a modality-agnostic, privacy-preserving form reusable across clinical tasks without exposing raw waveform data or requiring model retraining. Across 7 downstream tasks, spanning cross-modal reconstruction, cardiovascular disease classification, hypertension detection, mortality prediction, and demographic inference, biosignal fingerprints achieve competitive or superior performance compared to leading domain-specialist foundation models in frozen settings, including an AUROC of 0.974 for five-class CVD classification and 0.877 for hypertension detection, with a maximum improvement of 27.7% in AUROC across 5 classification tasks. Critically, strong performance is maintained with only a single modality, enabling deployment in resource-constrained, single-sensor environments typical of real-world wearable monitoring, with direct implications for continuous cardiovascular monitoring across clinical and consumer health settings.
Zhangdaihong Liu, Chang Liu, Fenglin Liu +4
Aug 13, 2026cs.LG

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Hamza Shafiq, Hung Manh Pham, Bin Zhu +3