eess.IVSep 1, 2026

Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolution

Authors: Abdulkader GhandouraMarsil ZakourWilliam ConsagraYogesh Rathi

Abstract

Resolving complex fiber geometries in brain white matter requires high-resolution diffusion MRI at the cost of long acquisition times. This leads many clinical protocols to opt for low-resolution scans, making downstream microstructure estimation and tractography challenging. Implicit neural representations (INRs) can model the diffusion signal continuously, enabling native single-subject super-resolution by querying the network at arbitrary spatial coordinates, yet existing methods often suffer from long training times and lack a mechanism to incorporate anatomical priors to regularize super-resolution by constraining the space of plausible reconstructions. To address these limitations, we propose a novel transfer-learning framework that pre-trains an INR on a high-resolution template and then adapts it to subject-specific scans via registration and fine-tuning. For 4×4\times through-plane super-resolution from 5 mm to 1.25 mm on Human Connectome Project (HCP) data, our method reduces NRMSE by 36-49% and increases FSIM by 24-43% over a recent baseline with 6×6\times faster training, outperforming competing INR-based methods across both image quality and domain-specific metrics. Code is available on the project page at https://abdulkaderghandoura.github.io/research/msc-thesis/ .

Explore similar work

Jul 22, 2026cs.CV

SIINR: Structurally Informed Implicit Neural Representations for super-resolution with uncertainty quantification of clinical quality diffusion MRI datasets

Diffusion Magnetic Resonance Imaging (dMRI) is a powerful tool for probing brain microstructure, but clinical acquisitions are often limited by low out-of-plane resolution, resulting in degraded structural information and reduced utility for advanced analysis. We introduce SIINR (Structurally Informed Implicit Neural Representations), a general framework for super-resoltion of clinical dMRI datasets while quantifying uncertainty in the reconstructed outputs. SIINR utilizes a supervised 3D U-net as a prior and combines it with a self-supervised implicit neural representation (INR) that fuses the high-resolution prior and the original low-resolution data. The INR enables joint modeling across spatial and angular domains, enforces data consistency, and provides analytic approximate posterior distributions for downstream uncertainty quantification. We validate the framework on a diverse set of open-access dMRI datasets, demonstrating that SIINR outperforms standard interpolation methods in both quantitative error metrics and qualitative anatomical fidelity. Experiments on clinical cases, including subjects with multiple sclerosis and brain lesions, illustrate the framework its ability to propagate intensity changes and flag uncertain regions in challenging scenarios. SIINR is flexible, modular, and can be adapted to different upsampling ratios and downstream tasks, providing a principled approach for enhancing clinical dMRI and supporting robust interpretation of derived neuroimaging metrics.
Tom Hendriks, William Consagra, Anna Vilanova +2
Aug 9, 2026cs.CV

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.
Mojtaba Safari, Hang Yu, Zach Eidex +10
May 4, 2026cs.CV

Self-Supervised Spatial And Zero-Shot Angular Super-Resolution by Spatial-Angular Implicit Representation For Rotating-View SNR-Efficient Diffusion MRI

Rotating-view thick-slice acquisition is highly SNR-efficient for mesoscale diffusion MRI (dMRI) but requires numerous rotating views to satisfy Nyquist sampling, resulting in long scan time. We propose a self-supervised Spatial-Angular Implicit Neural Representation (SA-INR) that reconstructs high-resolution dMRI from a single view per diffusion direction, representing a massive acceleration. Our model, an MLP conditioned on a b=0 structural prior and the b-direction via FiLM, is trained end-to-end on the anisotropic input. The framework not only accurately reconstructs the trained b-directions (spatial SR) but also learns a continuous q-space representation, enabling high-fidelity "zero-shot" synthesis of unseen b-directions (angular SR). On simulated data, our method achieved high fidelity for both trained (34.82 dB) and unseen (33.08 dB) directions. Most importantly, the synthesized angular data also improved the quantitative accuracy of downstream DTI model fitting. Our SA-INR framework breaks the classical sampling limits, paving the way for fast, quantitative high-resolution dMRI.
Yinzhe Wu, Hongyu Rui, Fanwen Wang +3